CoChat

Sensitivity and selectivity of intraneural stimulation using a silicon electrode array

Open access
Rutten, W.L.C., van Wier, H.J., Put, J.H.M. · 1991 · IEEE Transactions on Biomedical Engineering
Cited by 129

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Artificial electrical stimulation of peripheral nerves needs the development of multielectrode devices which stimulate individual fibers or small groups in a selective and sensitive way. To this end, a multielectrode array in silicon technology has been developed, as well as experimental paradigms and model calculations for sensitivity and selectivity measures. The array consists of twelve platinum electrode sites (10 x 50 microns at 50 microns interdistance) on a 45 microns thick tip-shaped silicon substrate and a Si3N4 insulating glass cover layer. The tip is inserted in the peroneal nerve of the rat during acute experiments to stimulate alpha motor fibers of the extensor digitorum longus muscle. Sensitivity calculations and experiments show a cubic dependence of the number of stimulated motor units on current amplitude of the stimulatory pulse (recruitment curves), starting at single motor level. Selectivity was tested by a method based on the refractory properties of neurons. At the lowest stimulus levels (for one motor unit) selectivity is maximal when two electrodes are separated by 200-250 microns, which was estimated also on theoretical grounds. The study provides clues for future designs of two- and three-dimensional devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.76386

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 129

Metadata

Authors
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1991-02
Volume
38
Issue
2
Pages
192-198
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2137544488
Cited by
129
References
3
FWCI
0.89
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity and selectivity of intraneural stimulation using a silicon electrode array. https://app.cochat.ai/papers/10.1109/10.76386
The paper
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991). Sensitivity and selectivity of intraneural stimulation using a silicon electrode array. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.76386

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.