Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Artificial electrical stimulation of peripheral nerves needs the development of multielectrode devices which stimulate individual fibers or small groups in a selective and sensitive way. To this end, a multielectrode array in silicon technology has been developed, as well as experimental paradigms and model calculations for sensitivity and selectivity measures. The array consists of twelve platinum electrode sites (10 x 50 microns at 50 microns interdistance) on a 45 microns thick tip-shaped silicon substrate and a Si3N4 insulating glass cover layer. The tip is inserted in the peroneal nerve of the rat during acute experiments to stimulate alpha motor fibers of the extensor digitorum longus muscle. Sensitivity calculations and experiments show a cubic dependence of the number of stimulated motor units on current amplitude of the stimulatory pulse (recruitment curves), starting at single motor level. Selectivity was tested by a method based on the refractory properties of neurons. At the lowest stimulus levels (for one motor unit) selectivity is maximal when two electrodes are separated by 200-250 microns, which was estimated also on theoretical grounds. The study provides clues for future designs of two- and three-dimensional devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Bowman, B. R., & Erickson, R. C. (1985) · Annals of Biomedical Engineering · doi:10.1007/bf02371251 · Cited by 66
Cited by
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
“The same type of calculation as previously made for selective stimulation of nerve fibers in rat peroneal nerve (isotropic conductor, local approach) (26) could be applied, by reciprocity, to the case where the device is used to sense natural activity from afferent fibers.”
BackgroundSelf-citationA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
The effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
He, W., McConnell, G. C., & Bellamkonda, R. V. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/009 · Cited by 177
Silicon-neuron junction: capacitive stimulation of an individual neuron on a silicon chip.
Fromherz, P., & Stett, A. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1670 · Cited by 167
Nanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode
Polasek, K. H., Hoyen, H. A., Keith, M. W., & Tyler, D. J. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891383 · Cited by 111
Inversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
“There is a stochastic distribution of Nodes of Ranvier and axon sizes that results in a distributed recruitment within the nerve limiting the maximum effective electrode density [102,103].”
BackgroundFabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93
Subfascicle stimulation selectivity with the flat interface nerve electrode
Leventhal, D. K., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569266 · Cited by 81
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Yoshida, K., & Horch, K. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368649 · Cited by 69
Raspopovic, S., Capogrosso, M., Badia, J., Navarro, X., & Micera, S. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2189021 · Cited by 63
Chronic Measurement of the Stimulation Selectivity of the Flat Interface Nerve Electrode
Leventhal, D. K., & Durand, D. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827535 · Cited by 55
“fibers activated by the first contact are still refractory [4], [8], [21].”
Selective motor unit recruitment via intrafascicular multielectrode stimulation
McDonnall, D., Clark, G. A., & Normann, R. A. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-047 · Cited by 53
Optimization of selective stimulation parameters for multi-contact electrodes
Fisher, L. E., Tyler, D. J., & Triolo, R. J. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-25 · Cited by 45
Neuro-electronic interfacing with multielectrode arrays
Rutten, W. L. C., Smit, J. P. A., Frieswijk, T. A., Bielen, J. A., Brouwer, A. L. H., Buitenweg, J. R., & Heida, C. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765188 · Cited by 39
Self-citationNormann, R. A., Dowden, B. R., Frankel, M. A., Wilder, A. M., Hiatt, S. D., Ledbetter, N. M., Warren, D. A., & Clark, G. A. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026019 · Cited by 37
“These include surface electrodes [1, 2], epimysial electrodes [3], electrodes that are implanted within the central nervous systems [4, 5], peripheral nerve stimulating electrodes [6–8], and intrafascicular electrodes [9–13].”
BackgroundEndoneural selective stimulating using wire-microelectrode arrays
Smit, J. P. A., Rutten, W. L. C., & Boom, H. B. K. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808943 · Cited by 20
Self-citationStoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066018 · Cited by 18
Self-citationInfluence of synchronous and sequential stimulation on muscle fatigue
Thomsen, M., & Veltink, P. H. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02530036 · Cited by 18
Metadata
- Authors
- Rutten, W. L. C., van Wier, H. J., & Put, J. H. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991-02
- Volume
- 38
- Issue
- 2
- Pages
- 192-198
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2137544488
- Cited by
- 129
- References
- 3
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.