The DOI matches its Crossref record; 20 of the 24 references it cites were found in a registry or an index.
A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array
Abstract
A method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilitate cortical penetration. Each needle is electrically isolated from the other needles, and is about 0.09 mm thick at its base and 1.5 mm long. The sharpened end of each needle is coated with platinum to facilitate charge transfer into neural tissue. The following manufacturing processes were used to create this array. 1) Thermomigration of 100 aluminum pads through an n-type silicon block. This creates trails of highly conductive p+ silicon isolated from each other by opposing pn junctions. 2) A combination of mechanical and chemical micromachining which creates individual penetrating needles of the p+ silicon trails. 3) Metal deposition to create active electrode areas and electrical contact pads. 4) Array encapsulation with polyimide. The geometrical, mechanical, and electrical properties of these arrays should make them well suited as interfaces to cortical tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes (Campbell et al. 1991), with recent improvements bringing this number closer to one thousand (Shobe et al. 2015; Scholvin et al. 2016; Buszáki et al. 2015), even on a single probe (Jun et al. 2017).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Campbell et al. 1991
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Chemical Etching of Silicon: IV . Etching Technology
Schwartz, B., & Robbins, H. (1976) · Journal of The Electrochemical Society · doi:10.1149/1.2132721 · Cited by 355
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Robbins, H., & Schwartz, B. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427617 · Cited by 199
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
A 100 electrode intracortical array: structural variability.
Campbell, P. K., Jones, K. E., & Normann, R. A. (1990) · PubMed · Cited by 35
Self-citationMercer, H. D., & White, R. L. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326282 · Cited by 33
Anthony, T. R., & Cline, H. E. (1976) · Journal of Applied Physics · doi:10.1063/1.322973 · Cited by 25
Random walk of liquid droplets migrating in silicon
Anthony, T. R., & Cline, H. E. (1976) · Journal of Applied Physics · doi:10.1063/1.323007 · Cited by 25
Printed circuit microelectrodes
PICKARD, R. S. (1979) · Trends in Neurosciences · doi:10.1016/0166-2236(79)90101-2 · Cited by 23
A chronic intracortical electrode array: preliminary results.
Campbell, P. K., Normann, R. A., Horch, K. W., & Stensaas, S. S. (1989) · PubMed · Cited by 20
Self-citationExcitation of visual cortex neurons by local intracortical microstimulation
Ronner, S. F., & Lee, B. G. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90270-4 · Cited by 18
A silicon based electrode array for intracortical stimulation: structural and electrical properties
Normann, R. A., Campbell, P. K., & Jones, K. E. (2003) · doi:10.1109/iembs.1989.95626 · Cited by 16
Self-citationNormann, R. A., Campbell, P. K., & Li, W. P. (1988) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1988.94953 · Cited by 12
Self-citationMicrofabrication technology for development of chronic neural information transducers
Edell, D. J., McNeil, V. M., & Clark, L. D. (1986) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.1986.191144 · Cited by 7
A System For Impact Insertion Of A 100 Electrode Array Into Cortical Tissue
Rousche, P. J., & Normann, R. A. (2005) · doi:10.1109/iembs.1990.691182 · Cited by 7
Self-citationAccelerated Testing of Polyimide Coatings for Neural Prostheses
McHardy, J., Basiulis, D. I., Angsten, G., Higley, L. R., & Leyden, R. N. (1989) · ACS symposium series · doi:10.1021/bk-1989-0407.ch014 · Cited by 5
Flagged first, then by citations
4 of the 24 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
- hahn, 1987, Innovative techniques for protective coatings of neural prosthetic devices Material development and evaluation
- penfield, 1950, The Cerebral Cortex of Man
- de yoe, 1983, An investigation in the awake macaque of the threshold for detection of electrical currents applied to striate cortex Psychophysical properties and laminar differences
Cited by
Sorted by citations
Yuk, H., Lu, B., & Zhao, X. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,148
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Metadata
- Authors
- Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 8
- Pages
- 758-768
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111937020
- Cited by
- 881
- References
- 24
- Citations by year
- 2026: 21 · 2025: 29 · 2024: 41 · 2023: 24 · 2022: 35 · 2021: 32 · 2020: 40 · 2019: 39 · 2018: 34 · 2017: 41 · 2016: 36 · 2015: 41 · 2014: 43 · 2013: 56 · 2012: 41
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- neural interfaces, thermomigration, p+ silicon, micromachining, platinum coating, polyimide encapsulation, monocrystalline silicon substrate, galvanic isolation
- MeSH terms
- Animals, Biocompatible Materials, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Materials Testing, Microscopy, Electron, Scanning, Silicon, Somatosensory Cortex, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review