The DOI matches its Crossref record; 20 of the 24 references it cites were found in a registry or an index.
A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array
Abstract
A method has been developed for the manufacture of a "three-dimensional" electrode array geometry for chronic intracortical stimulation. This silicon based array consists of a 4.2 x 4.2 x 0.12 mm thick monocrystalline substrate, from which project 100 conductive, silicon needles sharpened to facilitate cortical penetration. Each needle is electrically isolated from the other needles, and is about 0.09 mm thick at its base and 1.5 mm long. The sharpened end of each needle is coated with platinum to facilitate charge transfer into neural tissue. The following manufacturing processes were used to create this array. 1) Thermomigration of 100 aluminum pads through an n-type silicon block. This creates trails of highly conductive p+ silicon isolated from each other by opposing pn junctions. 2) A combination of mechanical and chemical micromachining which creates individual penetrating needles of the p+ silicon trails. 3) Metal deposition to create active electrode areas and electrical contact pads. 4) Array encapsulation with polyimide. The geometrical, mechanical, and electrical properties of these arrays should make them well suited as interfaces to cortical tissue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Current state-of-the-art silicon-based in vivo systems do not commonly feature more than hundreds of electrodes (Campbell et al. 1991), with recent improvements bringing this number closer to one thousand (Shobe et al. 2015; Scholvin et al. 2016; Buszáki et al. 2015), even on a single probe (Jun et al. 2017).”
From Realizing flexible bioelectronic medicines for accessing the peripheral nerves – technology considerations (2018) · cites this paper as Campbell et al. 1991
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Chemical Etching of Silicon: IV . Etching Technology
Schwartz, B., & Robbins, H. (1976) · Journal of The Electrochemical Society · doi:10.1149/1.2132721 · Cited by 355
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Robbins, H., & Schwartz, B. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427617 · Cited by 199
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Thin-Film Multiple Electrode Probes: Possibilities and Limitations
Prohaska, O. J., Olcaytug, F., Pfundner, P., & Dragaun, H. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325894 · Cited by 103
Mechanical factors in the design of chronic recording intracortical microelectrodes
Goldstein, S. R., & Salcman, M. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324190 · Cited by 53
A 100 electrode intracortical array: structural variability.
Campbell, P. K., Jones, K. E., & Normann, R. A. (1990) · PubMed · Cited by 35
Self-citationMercer, H. D., & White, R. L. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326282 · Cited by 33
Flagged first, then by citations
4 of the 24 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
- hahn, 1987, Innovative techniques for protective coatings of neural prosthetic devices Material development and evaluation
- penfield, 1950, The Cerebral Cortex of Man
- de yoe, 1983, An investigation in the awake macaque of the threshold for detection of electrical currents applied to striate cortex Psychophysical properties and laminar differences
Cited by
Sorted by citations
Yuk, H., Lu, B., & Zhao, X. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,148
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 695
Nanotechnology and the transdermal routeA state of the art review and critical appraisal
Cevc, G., & Vierl, U. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.10.016 · Cited by 560
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Recent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 372
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 364
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationMicroneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 344
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Microfabricated Microneedles for Gene and Drug Delivery
McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.289 · Cited by 335
Challenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 351
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305
Self-citationToward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Dynamic Balance of Excitation and Inhibition in Human and Monkey Neocortex
Dehghani, N., Peyrache, A., Teleńczuk, B., Quyen, M. L. V., Halgren, E., Cash, S. S., Hatsopoulos, N. G., & Alain Destexhe, A. (2016) · Scientific Reports · doi:10.1038/srep23176 · Cited by 282
Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications
Ashraf, M. W., Tayyaba, S., & Afzulpurkar, N. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12063648 · Cited by 266
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
Characterization of parylene C as an encapsulation material for implanted neural prostheses
Hassler, C., von Metzen, R. P., Ruther, P., & Stieglitz, T. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31584 · Cited by 263
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Next-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Criteria for the Selection of Materials for Implanted Electrodes
Geddes, L. A., & Roeder, R. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1581292 · Cited by 240
Arts, L. P. A., & van den Broek, E. L. (2022) · Nature Computational Science · doi:10.1038/s43588-021-00183-z · Cited by 238
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Self-citationInformation about movement direction obtained from synchronous activity of motor cortical neurons
Hatsopoulos, N. G., Ojakangas, C. L., Paninski, L., & Donoghue, J. P. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15706 · Cited by 234
Flexible polyimide microelectrode array for in vivo recordings and current source density analysis
Cheung, K. C., Renaud, P., Tanila, H., & Djupsund, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.035 · Cited by 236
Mobility performance with a pixelized vision system.
Cha, K., Horch, K. W., & Normann, R. A. (1992) · Vision Research · doi:10.1016/0042-6989(92)90229-c · Cited by 226
Self-citationElastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
Biomaterials for the central nervous system
Zhong, Y., & Bellamkonda, R. V. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0071 · Cited by 221
3D flexible multichannel neural probe array
Takeuchi, S., Suzuki, T. J., Mabuchi, K., & Fujita, H. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/1/014 · Cited by 221
Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain
Kim, S., Tathireddy, P., Normann, R. A., & Solzbacher, F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908429 · Cited by 215
Self-citationSingle-unit neural recording with active microelectrode arrays
Bai, Q., & Wise, K. D. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.936367 · Cited by 214
Li, Y., Zhang, H., Yang, R., Laffitte, Y., Schmill, U., Hu, W., Kaddoura, M., Blondeel, E. J. M., & Cui, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0077-y · Cited by 217
Tapping into spinal circuits to restore motor function
Barbeau, H., McCrea, D. A., O'Donovan, M. J., Rossignol, S., Grill, W. M., & Lemay, M. A. (1999) · Brain Research Reviews · doi:10.1016/s0165-0173(99)00008-9 · Cited by 211
Spatiotemporal dynamics of neocortical excitation and inhibition during human sleep
Peyrache, A., Dehghani, N., Eskandar, E. N., Madsen, J. R., Anderson, W. S., Donoghue, J., Hochberg, L. R., Halgren, E., Cash, S. S., & Alain Destexhe, A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1109895109 · Cited by 220
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Close-Packed Silicon Microelectrodes for Scalable Spatially Oversampled Neural Recording
Scholvin, J., Kinney, J. P., Bernstein, J. G., Moore-Kochlacs, C., Kopell, N., Fonstad, C. G., & Boyden, E. S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406113 · Cited by 203
Recent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
Negi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 202
Materials for stretchable electronics in bioinspired and biointegrated devices
Kim, D., Lu, N., Huang, Y. Y., & Rogers, J. A. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.36 · Cited by 201
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Self-citationMicroneedles for transdermal drug delivery: a systematic review
Dharadhar, S., Majumdar, A. S., Dhoble, S., & Patravale, V. B. (2018) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2018.1539497 · Cited by 198
NeuroMEMS: Neural Probe Microtechnologies
Hajj-Hassan, M., Chodavarapu, V. P., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 194
Zhang, J., Laiwalla, F., Kim, J. A., Urabe, H., Wagenen, R. V., Song, Y., Connors, B. W., Zhang, F., Deisseroth, K. A., & Nurmikko, A. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055007 · Cited by 198
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 195
A 32-site neural recording probe fabricated by DRIE of SOI substrates
Peter Norlin, A., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. A. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 182
Self-citationOlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
Arrays of hollow out-of-plane microneedles for drug delivery
Stoeber, B., & Liepmann, D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844843 · Cited by 178
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 174
Carbon nanotube-based multi electrode arrays for neuronal interfacing: progress and prospects
Bareket, L., & Hanein, Y. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2012.00122 · Cited by 170
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 183
Reading speed with a pixelized vision system
Cha, K., Boman, D. K., Horch, K., & Normann, R. A. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000673 · Cited by 168
Self-citationIntegrated wireless neural interface based on the Utah electrode array
Kim, S., Bhandari, R., Klein, M., Negi, S., Rieth, L., Tathireddy, P., Toepper, M., Oppermann, H., & Solzbacher, F. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9251-y · Cited by 165
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2108770 · Cited by 168
Polymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 168
Materials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. F. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 162
Sparse and Selective Odor Coding by Mitral/Tufted Neurons in the Main Olfactory Bulb
Davison, I. G., & Katz, L. C. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.3779-06.2007 · Cited by 161
Microfabrication of functional polyimide films and microstructures for flexible MEMS applications
Dong, Z., He, Q., Shen, D., Gong, Z., Zhang, D., Zhang, W., Ono, T., & Jiang, Y. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00503-5 · Cited by 161
Techniques for extracting single-trial activity patterns from large-scale neural recordings
Churchland, M. M., Yu, B. M., Sahani, M., & Shenoy, K. V. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2007.11.001 · Cited by 163
Ultra-thin flexible polyimide neural probe embedded in a dissolvable maltose-coated microneedle
Xiang, Z., Yen, S.-C., Xue, N., Sun, T., Tsang, W. M., Zhang, S., Liao, L., Thakor, N. V., & Lee, C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/6/065015 · Cited by 157
3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Liu, Y., Gutierrez, C. A., Hoang, T., Pikov, V., & Meng, E. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 159
Review of polymer MEMS micromachining
Kim, B., & Meng, E. F. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/1/013001 · Cited by 152
Mechanical and Biological Interactions of Implants with the Brain and Their Impact on Implant Design
Prodanov, D., & Delbeke, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00011 · Cited by 152
Nanofabricated Ultraflexible Electrode Arrays for High‐Density Intracortical Recording
Wei, X., Luan, L., Zhao, Z., Li, X., Zhu, H., Potnis, O., & Xie, C. (2018) · Advanced Science · doi:10.1002/advs.201700625 · Cited by 149
Guo, L., Guvanasen, G. S., Liu, X., Tuthill, C., Nichols, T. R., & DeWeerth, S. P. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2192932 · Cited by 144
Flexible Electrodes for Brain–Computer Interface System
Wang, J., Wang, T., Liu, H., Wang, K., Kumi, M., Feng, Z., Li, P., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211012 · Cited by 138
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Optimal Electrode Size for Multi-Scale Extracellular-Potential Recording From Neuronal Assemblies
Viswam, V., Obien, M. E. J., Franke, F., Frey, U., & Hierlemann, A. R. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00385 · Cited by 136
Clinical applications of penetrating neural interfaces and Utah Electrode Array technologies
Normann, R. A., & Fernandez, E. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/061003 · Cited by 135
Self-citationA floating metal microelectrode array for chronic implantation
Musallam, S., Bak, M. J., Troyk, P. R., & Andersen, R. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.005 · Cited by 137
Flexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G. Z. J., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 135
Wang, J., He, T., & Lee, C. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.104039 · Cited by 129
Lee, J. L., Ozden, I., Song, Y., & Nurmikko, A. V. (2015) · Nature Methods · doi:10.1038/nmeth.3620 · Cited by 128
Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration
Kuo, J. T. W., Kim, B., Hara, S. A., Lee, C. D., Gutierrez, C. A., Hoang, T. Q., & Meng, E. F. (2012) · Lab on a Chip · doi:10.1039/c2lc40935f · Cited by 127
Negi, S., Bhandari, R., Rieth, L. W., Wagenen, R. V., & Solzbacher, F. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.016 · Cited by 127
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Oweiss, K. G., Mason, A. J., Suhail, Y., Kamboh, A. M., & Thomson, K. E. (2007) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2007.897726 · Cited by 126
Lee, J. H., Kim, H., Kim, J. H., & Lee, S. (2016) · Lab on a Chip · doi:10.1039/c5lc00842e · Cited by 126
Assessment of the biocompatibility of photosensitive polyimide for implantable medical device use
Sun, Y., Lacour, S. P., Brooks, R. A., Rushton, N., Fawcett, J. W., & Cameron, R. E. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32125 · Cited by 122
Subthreshold Operation of Organic Electrochemical Transistors for Biosignal Amplification
Venkatraman, V., Friedlein, J. T., Giovannitti, A., Maria, I. P., McCulloch, I. A., McLeod, R. R., & Rivnay, J. (2018) · Advanced Science · doi:10.1002/advs.201800453 · Cited by 121
Recent Progress on Microelectrodes in Neural Interfaces
Kim, G. H., Kim, K., Lee, E., An, T., Choi, W., Lim, G., & Shin, J. H. (2018) · Materials · doi:10.3390/ma11101995 · Cited by 131
Thin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118
Ainslie, K. M., & Desai, T. A. (2008) · Lab on a Chip · doi:10.1039/b806446f · Cited by 116
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Recent advances in bioelectronics chemistry
Fang, Y., Meng, L., Promiński, A., Schaumann, E. N., Seebald, M., & Tian, B. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00333f · Cited by 119
Metadata
- Authors
- Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1991
- Volume
- 38
- Issue
- 8
- Pages
- 758-768
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111937020
- Cited by
- 881
- References
- 24
- Citations by year
- 2026: 21 · 2025: 29 · 2024: 41 · 2023: 24 · 2022: 35 · 2021: 32 · 2020: 40 · 2019: 39 · 2018: 34 · 2017: 41 · 2016: 36 · 2015: 41 · 2014: 43 · 2013: 56 · 2012: 41
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- neural interfaces, thermomigration, p+ silicon, micromachining, platinum coating, polyimide encapsulation, monocrystalline silicon substrate, galvanic isolation
- MeSH terms
- Animals, Biocompatible Materials, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Materials Testing, Microscopy, Electron, Scanning, Silicon, Somatosensory Cortex, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review