The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Current Signature Analysis to Detect Induction Motor Faults
Abstract
Three-phase induction motors are the "workhorses" of industry and are the most widely used electrical machines. In an industrialized nation, they can typically consume between 40 to 50% of all the generated capacity of that country. This article focuses on the industrial application of motor current signature analysis (MCSA) to diagnose faults in three-phase induction motor drives. MCSA is a noninvasive, online monitoring technique for the diagnosis of problems in induction motors. Reliability-based maintenance (RBM) and condition-based maintenance (CBM) strategies are now widely used by industry, and health monitoring of electrical drives is a major feature in such programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Cause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors
Bonnett, A. H., & Soukup, G. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.148460 · Cited by 593
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Cameron, J. R., Thomson, W. T., & Dow, A. B. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0022 · Cited by 512
Self-citationCause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors
Bonnett, A. K., & Soukup, G. C. (2002) · Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference · doi:10.1109/papcon.1991.239667 · Cited by 489
Dorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
Self-citationDorrell, D. G., Thomson, W. T., & Roach, S. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530349 · Cited by 367
Self-citationCondition monitoring of electrical machines
Tavner, P., & Penman, J. (1987) · Durham Research Online (Durham University) · Cited by 353
Thomson, W. T., & Barbour, A. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.736320 · Cited by 173
Self-citationThomson, W. T., Rankin, D., & Dorrell, D. G. (1999) · IEEE Transactions on Energy Conversion · doi:10.1109/60.815075 · Cited by 163
Self-citationThomson, W. T. (2002) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2001.939425 · Cited by 141
Self-citation
Cited by
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Gangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Condition Monitoring and Fault Diagnosis of Induction Motors: A Review
Choudhary, A., Goyal, D., Shimi, S. L., & Akula, A. (2019) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-018-9286-z · Cited by 302
Machine Learning approach for Predictive Maintenance in Industry 4.0
Paolanti, M., Romeo, L., Felicetti, A., Mancini, A., Frontoni, E., & Loncarski, J. (2018) · 2018 14th IEEE/ASME International Conference on Mechatronic and Embedded Systems and Applications (MESA) · doi:10.1109/mesa.2018.8449150 · Cited by 296
“1) energy and efficiency, there have been many evaluation methods and devices developed, as in [5], 2) system condition monitoring, including the detection of motor faults, with various fault-detection techniques developed, as for instance in [6].”
Widodo, A., Yang, B.-S., & Han, T. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2005.11.031 · Cited by 296
Puche-Panadero, R., Pineda-Sanchez, M., Riera-Guasp, M., Roger-Folch, J., Hurtado-Perez, E., & Perez-Cruz, J. (2009) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2008.2003207 · Cited by 288
Soualhi, A., Clerc, G., & Razik, H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2230598 · Cited by 264
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Gurusamy, V., Bostanci, E., Li, C., Qi, Y., & Akin, B. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3013128 · Cited by 93
Climente-Alarcon, V., Antonino-Daviu, J. A., Riera-Guasp, M., Puche-Panadero, R., & Escobar, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.05.001 · Cited by 78
“An equivalent formula is provided by other authors [1].”
ResultFeature‐based fault diagnosis system of induction motors using vibration signal
Han, T., Yang, B., & Yin, Z. (2007) · Journal of Quality in Maintenance Engineering · doi:10.1108/13552510710753069 · Cited by 37
Cira, F., Arkan, M., Gumus, B., & Goktas, T. (2016) · IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2016.7793717 · Cited by 31
Shrivastava, A., & Wadhwani, S. (2014) · International Conference on Recent Advances and Innovations in Engineering (ICRAIE-2014) · doi:10.1109/icraie.2014.6909160 · Cited by 18
Modelling and detection of bearing faults in Permanent Magnet Synchronous Motors
Rezig, A., N'Diaye, A., Mekideche, M. R., & Djerdir, A. (2012) · 2012 XXth International Conference on Electrical Machines · doi:10.1109/icelmach.2012.6350122 · Cited by 10
“For example authors in [2,3] show that faults in the stator winding due to insulation degradation are one of the main causes of induction machine failures.”
Background
Metadata
- Authors
- Thomson, W. T., & Fenger, M.
- Venue
- IEEE Industry Applications Magazine
- Published
- 2001-07
- Volume
- 7
- Issue
- 4
- Pages
- 26-34
- ISSN
- 1077-2618 (ISSN-L)
- 1558-0598
- OpenAlex
- W2026550072
- Cited by
- 1,139
- References
- 11
- FWCI
- 37.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.