The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Tissue classification based on 3D local intensity structures for volume rendering
Open accessAbstract
This paper describes a novel approach to tissue classification using three-dimensional (3D) derivative features in the volume rendering pipeline. In conventional tissue classification for a scalar volume, tissues of interest are characterized by an opacity transfer function defined as a one-dimensional (1D) function of the original volume intensity. To overcome the limitations inherent in conventional 1D opacity functions, we propose a tissue classification method that employs a multidimensional opacity function, which is a function of the 3D derivative features calculated from a scalar volume as well as the volume intensity. Tissues of interest are characterized by explicitly defined classification rules based on 3D filter responses highlighting local structures, such as edge, sheet, line, and blob, which typically correspond to tissue boundaries, cortices, vessels, and nodules, respectively, in medical volume data. The 3D local structure filters are formulated using the gradient vector and Hessian matrix of the volume intensity function combined with isotropic Gaussian blurring. These filter responses and the original intensity define a multidimensional feature space in which multichannel tissue classification strategies are designed. The usefulness of the proposed method is demonstrated by comparisons with conventional single-channel classification using both synthesized data and clinical data acquired with CT (computed tomography) and MRI (magnetic resonance imaging) scanners. The improvement in image quality obtained using multichannel classification is confirmed by evaluating the contrast and contrast-to-noise ratio in the resultant volume-rendered images with variable opacity values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marr, D. (1982) · Cumulative Index of Computer Aided Architectural Design · Cited by 5,733
Barlow, H. B. (1983) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(83)90030-5 · Cited by 5,424
Display of surfaces from volume data
Levoy, M. (1988) · IEEE Computer Graphics and Applications · doi:10.1109/38.511 · Cited by 2,446
The Visualization Toolkit: An Object-Oriented Approach to 3-D Graphics
Schroeder, W. J., & Lorenson, B. (1997) · Cited by 1,882
Drebin, R. A., Carpenter, L., & Hanrahan, P. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378484 · Cited by 1,612
Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80009-1 · Cited by 1,163
Self-citationEdge Detection and Ridge Detection with Automatic Scale Selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008097225773 · Cited by 1,024
Fast volume rendering using a shear-warp factorization of the viewing transformation
Lacroute, P., & Levoy, M. (1994) · Proceedings of the 21st annual conference on Computer graphics and interactive techniques - SIGGRAPH '94 · doi:10.1145/192161.192283 · Cited by 1,013
Quantitative magnetic resonance imaging of brain development in premature and mature newborns
Hüppi, P. S., Warfield, S., Kikinis, R., Barnes, P. D., Zientara, G. P., Jolesz, F. A., Tsuji, M. K., & Volpe, J. J. (1998) · Annals of Neurology · doi:10.1002/ana.410430213 · Cited by 692
Self-citationSemi-automatic generation of transfer functions for direct volume rendering
Kindlmann, G., & Durkin, J. W. (1998) · Proceedings of the 1998 IEEE symposium on Volume visualization · doi:10.1145/288126.288167 · Cited by 545
Perspective volume rendering of CT and MR images: applications for endoscopic imaging.
Rubin, G. D., Beaulieu, C. F., Argiro, V., Ringl, H., Norbash, A., Feller, J. F., Dake, M. D., Jeffrey, R. B., & Napel, S. A. (1996) · Radiology · doi:10.1148/radiology.199.2.8668772 · Cited by 397
Sato, Y., Nakajima, S., Atsumi, H., Koller, T., Gerig, G., Yoshida, S., & Kikinis, R. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029240 · Cited by 396
Self-citationRepresenting Local Structure Using Tensors II
Knutsson, H., Westin, C.-F., & Andersson, M. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-21227-7_51 · Cited by 355
Self-citationBrebin, R. A., Carpenter, L., & Hanrahan, P. (1998) · Seminal graphics · doi:10.1145/280811.281028 · Cited by 354
Edge detection and ridge detection with automatic scale selection
Lindeberg, T. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517113 · Cited by 345
Multiscale detection of curvilinear structures in 2-D and 3-D image data
Koller, T. M., Gerig, G., Szekely, G., & Dettwiler, D. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466846 · Cited by 314
Haralick, R. M., Watson, L. T., & Laffey, T. J. (1983) · The International Journal of Robotics Research · doi:10.1177/027836498300200105 · Cited by 280
Multispectral analysis of magnetic resonance images.
Vannier, M. W., Butterfield, R. L., Jordan, D., Murphy, W. A., Levitt, R. G., & Gado, M. (1985) · Radiology · doi:10.1148/radiology.154.1.3964938 · Cited by 253
Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040517 · Cited by 216
Computerized Detection of Pulmonary Nodules in Computed Tomography Images
GIGER, M. L., BAE, K. T., & MacMAHON, H. (1994) · Investigative Radiology · doi:10.1097/00004424-199404000-00013 · Cited by 200
Drebin, R. A., Carpenter, L., & Hanrahan, P. (1988) · Proceedings of the 15th annual conference on Computer graphics and interactive techniques · doi:10.1145/54852.378484 · Cited by 197
Partial-volume Bayesian classification of material mixtures in MR volume data using voxel histograms
Laidlaw, D. H., Fleischer, K. W., & Barr, A. H. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668696 · Cited by 188
CT angiography with volume rendering: advantages and applications in splanchnic vascular imaging.
Johnson, P. T., Heath, D. G., Kuszyk, B. S., & Fishman, E. K. (1996) · Radiology · doi:10.1148/radiology.200.2.8685358 · Cited by 128
A Tensor Framework for Multidimensional Signal Processing
Westin, C. (1994) · Cited by 97
Self-citationScale selection for differential operators
Lindeberg, T. (1994) · Springer eBooks · doi:10.1007/978-1-4757-6465-9_13 · Cited by 97
Peripheral vascular tree stenoses: detection with subtracted and nonsubtracted MR angiography.
Ho, K. Y. J. A. M., de Haan, M. W., Kessels, A. G. H., Kitslaar, P. J. E. H. M., & van Engelshoven, J. M. A. (1998) · Radiology · doi:10.1148/radiology.206.3.9494485 · Cited by 94
Cited by
Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80009-1 · Cited by 1,163
Self-citationMultidimensional transfer functions for interactive volume rendering
Kniss, J., Kindlmann, G., & Hansen, C. (2002) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2002.1021579 · Cited by 546
Li, Q., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1581411 · Cited by 349
Shape-Based Computer-Aided Detection of Lung Nodules in Thoracic CT Images
Ye, X., Lin, X., Dehmeshki, J., Slabaugh, G., & Beddoe, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2017027 · Cited by 297
Enhancement of Vascular Structures in3D and 2D Angiographic Images
Jerman, T., Pernus, F., Likar, B., & Spiclin, Z. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2550102 · Cited by 294
Metadata
- Authors
- Sato, Y., Westin, C., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., & Kikinis, R.
- Venue
- IEEE Transactions on Visualization and Computer Graphics
- Published
- 2000
- Volume
- 6
- Issue
- 2
- Pages
- 160-180
- ISSN
- 1077-2626 (ISSN-L)
- OpenAlex
- W2162106299
- Cited by
- 338
- References
- 26
- FWCI
- 21.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.