The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Recovering the position and orientation of free-form objects from image contours using 3D distance maps
Abstract
The accurate matching of 3D anatomical surfaces with sensory data such as 2D X-ray projections is a basic problem in computer and robot assisted surgery, In model-based vision, this problem can be formulated as the estimation of the spatial pose (position and orientation) of a 3D smooth object from 2D video images. The authors present a new method for determining the rigid body transformation that describes this match. The authors' method performs a least squares minimization of the energy necessary to bring the set of the camera-contour projection lines tangent to the surface. To correctly deal with projection lines that penetrate the surface, the authors consider the minimum signed distance to the surface along each line (i.e., distances inside the object are negative). To quickly and accurately compute distances to the surface, the authors introduce a precomputed distance map represented using an octree spline whose resolution increases near the surface. This octree structure allows the authors to quickly find the minimum distance along each line using best-first search. Experimental results for 3D surface to 2D projection matching are presented for both simulated and real data. The combination of the authors' problem formulation in 3D, their computation of line to surface distances with the octree-spline distance map, and their simple minimization technique based on the Levenberg-Marquardt algorithm results in a method that solves the 3D/2D matching problem for arbitrary smooth shapes accurately and quickly.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
On bending invariant signatures for surfaces
Elad, A., & Kimmel, R. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1233902 · Cited by 458
COSMOS-A representation scheme for 3D free-form objects
Dorai, C., & Jain, A. K. (1997) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.625113 · Cited by 438
A Correlation-Based Approach to Robust Point Set Registration
Tsin, Y., & Kanade, T. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24672-5_44 · Cited by 416
An algorithmic overview of surface registration techniques for medical imaging
Audette, M. A., Ferrie, F. P., & Peters, T. M. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00014-1 · Cited by 406
Gu, C., Lim, J. J., Arbelaez, P., & Malik, J. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206727 · Cited by 347
Deformable models in medical image analysis
McInerney, T., & Terzopoulos, D. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534069 · Cited by 329
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820027 · Cited by 305
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines
Szeliski, R., & Lavall�e, S. (1996) · International Journal of Computer Vision · doi:10.1007/bf00055001 · Cited by 296
Self-citationExpression-Invariant 3D Face Recognition
Bronstein, A. M., Bronstein, M. M., & Kimmel, R. (2003) · Lecture Notes in Computer Science · doi:10.1007/3-540-44887-x_8 · Cited by 270
“Gold standard” data for evaluation and comparison of 3D/2D registration methods
Tomaževič, D., Likar, B., & Pernuš, F. (2004) · Computer Aided Surgery · doi:10.3109/10929080500097687 · Cited by 40
Gendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Accurate and precise 2D–3D registration based on X-ray intensity
Aouadi, S., & Sarry, L. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2007.05.006 · Cited by 30
Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
van der Bom, M. J., Pluim, J. P. W., Gounis, M. J., van de Kraats, E. B., Sprinkhuizen, S. M., Timmer, J., Homan, R., & Bartels, L. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/010 · Cited by 21
“Gold Standard” 2D/3D Registration of X-Ray to CT and MR Images
Tomaevič, D., Likar, B., & Pernuš, F. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45787-9_58 · Cited by 9
Metadata
- Authors
- Lavallee, S., & Szeliski, R.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 1995-04
- Volume
- 17
- Issue
- 4
- Pages
- 378-390
- ISSN
- 0162-8828 (ISSN-L)
- OpenAlex
- W2136244984
- Cited by
- 242
- References
- 1
- FWCI
- 14.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.