The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
A feature-based, robust, hierarchical algorithm for registering pairs of images of the curved human retina
Abstract
This paper describes a robust hierarchical algorithm for fully-automatic registration of a pair of images of the curved human retina photographed by a fundus microscope. Accurate registration is essential for mosaic synthesis, change detection, and design of computer-aided instrumentation. Central to the algorithm is a 12-parameter interimage transformation derived by modeling the retina as a rigid quadratic surface with unknown parameters. The parameters are estimated by matching vascular landmarks by recursively tracing the blood vessel structure. The parameter estimation technique, which could be generalized to other applications, is a hierarchy of models and methods, making the algorithm robust to unmatchable image features and mismatches between features caused by large interframe motions. Experiments involving 3,000 image pairs from 16 different healthy eyes were performed. Final registration errors less than a pixel are routinely achieved. The speed, accuracy, and ability to handle small overlaps compare favorably with retinal image registration techniques published in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischler, M. A., & Bolles, R. C. (1981) · Communications of the ACM · doi:10.1145/358669.358692 · Cited by 25,893
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Robust Regression and Outlier Detection
Piepel, G. F. (1989) · Technometrics · doi:10.1080/00401706.1989.10488524 · Cited by 6,144
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
Wiley Series in Probability and Statistics
(2008) · Wiley series in probability and statistics · doi:10.1002/series1345 · Cited by 4,217
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
Robust Statistics: The Approach Based on Influence Functions
Ruppert, D. (1987) · Technometrics · doi:10.2307/1269782 · Cited by 3,880
Least Median of Squares Regression
Rousseeuw, P. J. (1984) · Journal of the American Statistical Association · doi:10.1080/01621459.1984.10477105 · Cited by 3,835
Object modelling by registration of multiple range images
Chen, Y., & Medioni, G. (1992) · Image and Vision Computing · doi:10.1016/0262-8856(92)90066-c · Cited by 3,154
Robust regression using iteratively reweighted least-squares.
Holland, P. W., & Welsch, R. E. (1977) · Communications in Statistics - Theory and Methods · doi:10.1080/03610927708827533 · Cited by 2,115
Distance transformations in digital images
Borgefors, G. (1986) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(86)80047-0 · Cited by 1,898
Zhang, Z., Deriche, R., Faugeras, O., & Luong, Q.-T. (1995) · Artificial Intelligence · doi:10.1016/0004-3702(95)00022-4 · Cited by 1,367
Hierarchical model-based motion estimation
Bergen, J. R., Anandan, P., Hanna, K. J., & Hingorani, R. (1992) · Lecture Notes in Computer Science · doi:10.1007/3-540-55426-2_27 · Cited by 1,154
The Fitting of Power Series, Meaning Polynomials, Illustrated on Band-Spectroscopic Data
Beaton, A. E., & Tukey, J. W. (1974) · Technometrics · doi:10.1080/00401706.1974.10489171 · Cited by 1,010
Dynamic 3D models with local and global deformations: deformable superquadrics
Terzopoulos, D., & Metaxas, D. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.85659 · Cited by 781
The Development and Comparison of Robust Methods for Estimating the Fundamental Matrix
Torr, P. H. S., & Murray, D. W. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007927408552 · Cited by 755
Eye movements and visual cognition : scene perception and reading
Rayner, K. (2011) · Medical Entomology and Zoology · Cited by 503
A survey of hierarchical non-linear medical image registration
Lester, H., & Arridge, S. R. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00095-8 · Cited by 484
Robust Parameter Estimation in Computer Vision
Stewart, C. V. (1999) · SIAM Review · doi:10.1137/s0036144598345802 · Cited by 449
Self-citationA new algorithm for non-rigid point matching
Chui, H., & Rangarajan, A. (2002) · Proceedings IEEE Conference on Computer Vision and Pattern Recognition. CVPR 2000 (Cat. No.PR00662) · doi:10.1109/cvpr.2000.854733 · Cited by 440
Can, A., Shen, H., Turner, Tanenbaum, & Roysam (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.767088 · Cited by 434
Self-citationComputing occluding and transparent motions
Irani, M., Rousso, B., & Peleg, S. (1994) · International Journal of Computer Vision · doi:10.1007/bf01420982 · Cited by 372
A multimodal registration algorithm of eye fundus images using vessels detection and Hough transform
Zana, F., & Klein, J. C. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774169 · Cited by 303
Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines
Szeliski, R., & Lavall�e, S. (1996) · International Journal of Computer Vision · doi:10.1007/bf00055001 · Cited by 296
Robust Statistics: The Approach Based on Influence Functions
Hampel, F. R., Ronchetti, E. M., Rousseeuw, P. J., & Stahel, W. A. (2005) · Wiley Series in Probability and Statistics · doi:10.1002/9781118186435 · Cited by 292
Eye Movements and Visual Cognition: Scene Perception and Reading
(1992) · Springer Series in Neuropsychology · doi:10.1007/978-1-4612-2852-3 · Cited by 274
Comparing and evaluating interest points
Schmid, C., Mohr, R., & Bauckhage, C. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710723 · Cited by 265
True multi-image alignment and its application to mosaicing and lens distortion correction
Sawhney, H. S., & Kumar, R. (1999) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.754589 · Cited by 243
Hierarchical Model-Based Motion Estimation
Anandan, P., Bergen, J. R., Hanna, K. J., & Hingorani, R. (1993) · Motion Analysis and Image Sequence Processing · doi:10.1007/978-1-4615-3236-1_1 · Cited by 193
Automatic retinal image registration scheme using global optimization techniques
Matsopoulos, G. K., Mouravliansky, N. A., Delibasis, K. K., & Nikita, K. S. (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.748975 · Cited by 189
Registration of stereo and temporal images of the retina
Ritter, N., Owens, R., Cooper, J., Eikelboom, R. H., & Van Saarloos, P. P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774168 · Cited by 181
Can, A., Stewart, C. V., Roysam, B., & Tanenbaum, H. L. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.990145 · Cited by 106
Self-citationCideciyan, A. V. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.340749 · Cited by 103
Shen, H., Roysam, B., Stewart, C. V., Turner, J. N., & Tanenbaum, H. L. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908405 · Cited by 84
Self-citationProjective registration with difference decomposition
Gleicher, M. L. (2002) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1997.609345 · Cited by 79
MUSE: robust surface fitting using unbiased scale estimates
Miller, J. V., & Stewart, C. V. (1996) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1996.517089 · Cited by 77
Self-citationComputer-assisted, interactive fundus image processing for macular drusen quantitation
Shin, D. S., Javornik, N. B., & Berger, J. W. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90257-9 · Cited by 76
Becker, D. E., Can, A., Turner, J. N., Tanenbaum, H. L., & Roysam, B. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.650362 · Cited by 75
Self-citationKashiwase, M., Sata, T., Yamauchi, Y., Minoda, H., Usui, N., Iwasaki, T., Kurata, T., & Usui, M. (2000) · Ophthalmology · doi:10.1016/s0161-6420(99)00143-8 · Cited by 56
Robust hierarchical algorithm for constructing a mosaic from images of the curved human retina
Can, A., Stewart, C. V., & Roysam, B. (2003) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1999.784645 · Cited by 53
Self-citationReal-time algorithm for retinal tracking
Markow, M. S., Rylander, H. G., & Welch, A. J. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250583 · Cited by 37
Resolution of retinal digital colour images
Jensen, P. K., & Scherfig, E. (1999) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.1999.770508.x · Cited by 14
Q-warping: direct computation of quadratic reference surfaces
Wexler, Y., & Shashua, A. (2003) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1999.786960 · Cited by 10
Cited by
Image change detection algorithms: a systematic survey
Radke, R. J., Andra, S., Al-Kofahi, O., & Roysam, B. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.838698 · Cited by 1,869
Self-citationImage Alignment and Stitching: A Tutorial
Szeliski, R. (2007) · Foundations and Trends in Computer Graphics and Vision · doi:10.1561/0600000009 · Cited by 1,593
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“used the branching and crossover points of the blood vessel structure as feature points [276].”
MethodRetinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Mendonca, A. M., & Campilho, A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879955 · Cited by 921
Metadata
- Authors
- Can, A., Stewart, C. V., Roysam, B., & Tanenbaum, H. L.
- Venue
- IEEE Transactions on Pattern Analysis and Machine Intelligence
- Published
- 2002-03
- Volume
- 24
- Issue
- 3
- Pages
- 347-364
- ISSN
- 0162-8828 (ISSN-L)
- OpenAlex
- W2057771956
- Cited by
- 272
- References
- 44
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.