The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Abstract
In this retinal prosthesis project, a rehabilitative device is designed to replace the functionality of defective photoreceptors in patients suffering from retinitis pigmentosa (RP) and age-related macular degeneration (AMD). The device consists of an extraocular and an intraocular unit. The implantable component receives power and a data signal via a telemetric inductive link between the two units. The extraocular unit includes a video camera and video processing board, a telemetry protocol encoder chip, and an RF amplifier and primary coil. The intraocular unit consists of a secondary coil, a rectifier and regulator, a retinal chip with a telemetry protocol decoder, a stimulus signal generator, and an electrode array. This paper focuses on the design, fabrication, and testing of a microchip which serves as the telemetry protocol decoder and stimulus signal generator. It is fabricated by MOSIS with 1.2-mm CMOS technology and was demonstrated to provide the desired biphasic current stimulus pulses for an array of 100 retinal electrodes at video frame rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analog integrated circuit design
Hurst, S. L. (1998) · Microelectronics Journal · doi:10.1016/s0026-2692(97)00051-7 · Cited by 1,732
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 601
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592
Self-citationDesign of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (1997) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242
The Development of Subretinal Microphotodiodes for Replacement of Degenerated Photoreceptors
Zrenner, E., Miliczek, K.-D., Gabel, V. P., Graf, H. G., Guenther, E., Haemmerle, H., Hoefflinger, B., Kohler, K., Nisch, W., Schubert, M., et al. (1997) · Ophthalmic Research · doi:10.1159/000268025 · Cited by 214
Analysis of resonant coupled coils in the design of radio frequency transcutaneous links
Donaldson, N. D. N., & Perkins, T. A. (1983) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442388 · Cited by 211
Tang, Z., Smith, B., Schild, J. H., & Peckham, P. H. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.376158 · Cited by 188
Closed-loop class E transcutaneous power and data link for MicroImplants
Troyk, P. R., & Schwan, M. A. K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141197 · Cited by 177
Wyatt, J., & Rizzo, J. (1996) · IEEE Spectrum · doi:10.1109/6.490056 · Cited by 175
Majji, A. B., Humayun, M. S., Weiland, J. D., Suzuki, S., D’Anna, S. A., & de Juan, E. (1999) · PubMed · Cited by 172
Self-citationA single-channel implantable microstimulator for functional neuromuscular stimulation
Ziaie, B., Nardin, M., Coghlan, A. R., & Najafi, K. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.634643 · Cited by 138
A 64-site multishank CMOS low-profile neural stimulating probe
Kim, C., & Wise, K. D. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535406 · Cited by 103
Mutual inductance of air-cored coils: Effect on design of radio-frequency coupled implants
Flack, F. C., James, E. D., & Schlapp, D. M. (1971) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474736 · Cited by 91
A wireless single-chip telemetry-powered neural stimulation system
Von Arx, J. A., & Najafi, K. (2003) · 1999 IEEE International Solid-State Circuits Conference. Digest of Technical Papers. ISSCC. First Edition (Cat. No.99CH36278) · doi:10.1109/isscc.1999.759199 · Cited by 74
Dual unit visual intraocular prosthesis
Liu, W., McGucken, E., Vitchiechom, K., Clements, M., de Juan, E., & Humayun, M. S. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.758824 · Cited by 21
Self-citationA Multichannel Neuromuscular Microstimulator With Bi-directional Telemetry
Nardin, M., & Najafi, K. (2005) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1995.717085 · Cited by 19
Coil design for improved power transfer efficiency in inductive links
Zierhofer, C., & Hochmair, E. S. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.647541 · Cited by 13
Cited by
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Self-citationRetinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Self-citationWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Self-citationFully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Metadata
- Authors
- Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2000-10
- Volume
- 35
- Issue
- 10
- Pages
- 1487-1497
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2026659547
- Cited by
- 371
- References
- 19
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.