The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography
Abstract
The maximum likelihood (ML) expectation maximization (EM) approach in emission tomography has been very popular in medical imaging for several years. In spite of this, no satisfactory convergent modifications have been proposed for the regularized approach. Here, a modification of the EM algorithm is presented. The new method is a natural extension of the EM for maximizing likelihood with concave priors. Convergence proofs are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Maximum Likelihood from Incomplete Data via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1976) · Cited by 4,517
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Image reconstruction from projections : the fundamentals of computerized tomography
Herman, G. T. (1980) · Academic Press eBooks · Cited by 1,993
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Nonlinear Programming Analysis and Methods
Rodin, E. Y. (1977) · Computers & Mathematics with Applications · doi:10.1016/0898-1221(77)90071-2 · Cited by 1,278
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
Levitan, E., & Herman, G. T. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307826 · Cited by 445
On Use of the Em Algorithm for Penalized Likelihood Estimation
Green, P. J. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01798.x · Cited by 417
Cited by
An iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
Majorization-Minimization Algorithms in Signal Processing, Communications, and Machine Learning
Sun, Y., Babu, P., & Palomar, D. P. (2017) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2016.2601299 · Cited by 1,820
Hunter, D. R., & Lange, K. (2004) · The American Statistician · doi:10.1198/0003130042836 · Cited by 1,783
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
Optimization Transfer Using Surrogate Objective Functions
Lange, K., Hunter, D. R., & Yang, I. (2000) · Journal of Computational and Graphical Statistics · doi:10.1080/10618600.2000.10474858 · Cited by 808
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
What is the expectation maximization algorithm?
Do, C. B., & Batzoglou, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1406 · Cited by 607
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
Majorization–Minimization Algorithms for Wavelet-Based Image Restoration
Figueiredo, M. A. T., Bioucas-Dias, J. M., & Nowak, R. D. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909318 · Cited by 548
A unified approach to statistical tomography using coordinate descent optimization
Bouman, C. A., & Sauer, K. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491321 · Cited by 442
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424
Self-citationIterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
Parra, L., & Barrett, H. H. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700734 · Cited by 357
Ahn, S., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812251 · Cited by 344
Globally convergent algorithms for maximum a posteriori transmission tomography
Lange, K., & Fessler, J. A. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.465107 · Cited by 313
Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
Mumcuoglu, E. U., Leahy, R., Cherry, S. R., & Zhou, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363099 · Cited by 282
Platelets: a multiscale approach for recovering edges and surfaces in photon-limited medical imaging
Willett, R. M., & Nowak, R. D. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809622 · Cited by 279
Roveda, L., Magni, M., Cantoni, M., Piga, D., & Bucca, G. (2021) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2020.103711 · Cited by 80
Metadata
- Authors
- De Pierro, A. R.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1995-03
- Volume
- 14
- Issue
- 1
- Pages
- 132-137
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2156612134
- Cited by
- 475
- References
- 15
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.