The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Multimodality image registration by maximization of mutual information
Open accessAbstract
A new approach to the problem of multimodality medical image registration is proposed, using a basic concept from information theory, mutual information (MI), or relative entropy, as a new matching criterion. The method presented in this paper applies MI to measure the statistical dependence or information redundancy between the image intensities of corresponding voxels in both images, which is assumed to be maximal if the images are geometrically aligned. Maximization of MI is a very general and powerful criterion, because no assumptions are made regarding the nature of this dependence and no limiting constraints are imposed on the image content of the modalities involved. The accuracy of the MI criterion is validated for rigid body registration of computed tomography (CT), magnetic resonance (MR), and photon emission tomography (PET) images by comparison with the stereotactic registration solution, while robustness is evaluated with respect to implementation issues, such as interpolation and optimization, and image content, including partial overlap and image degradation. Our results demonstrate that subvoxel accuracy with respect to the stereotactic reference solution can be achieved completely automatically and without any prior segmentation, feature extraction, or other preprocessing steps which makes this method very well suited for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A 2D intraoperative X-ray can be registered to a 3D preoperative CT volume by maximizing its similarity to a rendered X-ray with respect to the camera pose [8, 14, 34].”
From Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering (2024) · cites this paper as [34]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions.”
From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While these metrics are positively correlated with pose differences when the perturbations in {K^v,T^xv,ω^D} are small, they are generally non-convex and fail to accurately represent pose offsets when perturbations are large.”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Conventional intensity-based methods mostly use hand-crafted similarity metrics between y v and its current best estimate y^v=(P(Kv,Txv)◦DωD)(x)fx1 as loss function. Common choices for the similarity metric are Normalized Cross Correlation (NCC), gradient information (Berger et al., 2016), or Mutual Information (MI) (Maes et al., 1997).”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 37,139
Pattern classification and scene analysis
Grenander, U., Duda, R., & Hart, P. (1974) · A Wiley-Interscience publication · doi:10.2307/1573081 · Cited by 17,399
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 12,040
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,079
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P. A., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,961
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & Cherry, A. S. R. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,636
Alignment by maximization of mutual information
Viola, P. A., & Wells, W. M. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.1995.466930 · Cited by 1,080
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 883
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Collignon, A. M. F., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534053 · Cited by 809
Self-citation
Flagged first, then by citations
Research works printed but not linked: 6
- fitzpatrick, 1994, Evaluation of retrospective image registration
- press, 1992, Numerical Recipes in C, 412
- collignon, 1995, automated multimodality medical image registration using information theory, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 263
- baddeley, 1992, an error metric for binary images, Proc IEEE Workshop on Robust Computer Vision, 59
- astola, 1982, entropy correlation coefficient, a measure of statistical dependence for categorized data, Proc Univ Vaasa Discussion Papers
- studholme, 1995, multiresolution voxel similarity measures for mr-pet registration, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 287
Cited by
Sorted by citations
Items 901–1,000 of 1,006
Volume image registration by cross-entropy optimization
Zhu, Y. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993135 · Cited by 50
McDonald, B. A., Zachiu, C., Christodouleas, J. P., Naser, M. A., Ruschin, M., Sonke, J., Thorwarth, D., Létourneau, D., Tyagi, N., Tadic, T., et al. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2022.1086258 · Cited by 49
Effectiveness of Statistical Features for Early Stage Internet Traffic Identification
Peng, L., Yang, B., Chen, Y., & Chen, Z. (2015) · International Journal of Parallel Programming · doi:10.1007/s10766-014-0337-2 · Cited by 49
Characterizing changes in MR images with color-coded Jacobians
Riddle, W. R., Li, R., Fitzpatrick, J. M., DonLevy, S. C., Dawant, B. M., & Price, R. R. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.01.078 · Cited by 49
Elseberg, J., Borrmann, D., & Nüchter, A. (2013) · Remote Sensing · doi:10.3390/rs5115871 · Cited by 49
Gradual Lesion Expansion and Brain Shrinkage Years After Stroke
Seghier, M. L., Ramsden, S., Lim, L., Leff, A. P., & Price, C. J. (2014) · Stroke · doi:10.1161/strokeaha.113.003587 · Cited by 49
A multi-image super-resolution algorithm applied to thermal imagery
Mandanici, E., Tavasci, L., Corsini, F., & Gandolfi, S. (2019) · Applied Geomatics · doi:10.1007/s12518-019-00253-y · Cited by 49
Sun, L., Verma, S. K., Michael, N., Chan, S. P., Yan, J., Sadananthan, S. A., Camps, S. G., Goh, H. J., Govindharajulu, P., Totman, J. J., et al. (2019) · Obesity · doi:10.1002/oby.22560 · Cited by 49
Self-injection ictal SPECT during partial seizures
Paesschen, W. V., Dupont, P. J., van Heerden, B., Vanbilloen, H. P., Mesotten, L., Maes, A., Driel, G. V., & Mortelmans, L. (2000) · Neurology · doi:10.1212/wnl.54.10.1994 · Cited by 49
Image registration and subtraction to detect active T 2 lesions in MS: an interobserver study
Tan, I. L., van Schijndel, R. A., Fazekas, F., Filippi, M., Freitag, P., Miller, D. H., Yousry, T. A., Pouwels, P. J. W., Adèr, H. J., & Barkhof, F. (2002) · Journal of Neurology · doi:10.1007/s00415-002-0712-6 · Cited by 49
Moore, C. S., Liney, G. P., & Beavis, A. W. (2004) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.26.147 · Cited by 49
Chaira, T. (2015) · CRC Press eBooks · doi:10.1201/b18019 · Cited by 49
Improved efficiency for MRI-SPET registration based on mutual information
Thurfjell, L., Lau, Y. H., Andersson, J., & Hutton, B. F. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000270 · Cited by 49
Torsten Rohlfing, B., West, J. B., Beier, J., Liebig, T., Taschner, C. A., & Thomale, U. (2000) · Computer Aided Surgery · doi:10.1002/igs.1003 · Cited by 49
Estimating average single-neuron visual receptive field sizes by fMRI
Keliris, G. A., Li, Q., Papanikolaou, A., Logothetis, N. K., & Smirnakis, S. M. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1809612116 · Cited by 48
Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering
Gopalakrishnan, V., Dey, N., & Golland, P. (2024) · 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52733.2024.01108 · Cited by 48
“A 2D intraoperative X-ray can be registered to a 3D preoperative CT volume by maximizing its similarity to a rendered X-ray with respect to the camera pose [8, 14, 34].”
BackgroundThe variability of MR axon radii estimates in the human white matter
Veraart, J., Raven, E. P., Edwards, L., Weiskopf, N., & Jones, D. K. (2021) · Human Brain Mapping · doi:10.1002/hbm.25359 · Cited by 50
Two-Stage Registration of SAR Images With Large Distortion Based on Superpixel Segmentation
Xiang, D., Pan, X., Ding, H., Cheng, J., & Sun, X. (2024) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2024.3392971 · Cited by 48
Bhushan, C., Haldar, J. P., Joshi, A. A., & Leahy, R. M. (2012) · PubMed · Cited by 48
An MR image-guided, voxel-based partial volume correction method for PET images
Wang, H., & Fei, B. (2011) · Medical Physics · doi:10.1118/1.3665704 · Cited by 48
Learning Multimodal Dictionaries
Monaci, G., Jost, P., Vandergheynst, P., Mailhé, B., Lesage, S., & Gribonval, R. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.901813 · Cited by 48
Validation of 3D multimodality roadmapping in interventional neuroradiology
Ruijters, D., Homan, R., Mielekamp, P., van de Haar, P., & Babić, D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/017 · Cited by 48
Automated tracking of stem cell lineages of Arabidopsis shoot apex using local graph matching
Liu, M., Yadav, R. K., Roy–Chowdhury, A. K., & Reddy, G. V. (2009) · The Plant Journal · doi:10.1111/j.1365-313x.2009.04117.x · Cited by 48
Qin, C., Tan, Z., Pan, Y., Li, Y., Wang, L., Ren, L., Zhou, W., & Wang, L. Y. (2017) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2017.00010 · Cited by 48
Rundo, L., Stefano, A., Militello, C., Russo, G. I., SABINI, M. G., D'Arrigo, C., Marletta, F., Ippolito, M., Mauri, G., Vitabile, S., et al. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.03.011 · Cited by 48
Virtual setup in orthodontics: planning and evaluation
Baan, F., de Waard, O., Bruggink, R., Xi, T., Ongkosuwito, E. M., & Maal, T. (2019) · Clinical Oral Investigations · doi:10.1007/s00784-019-03097-3 · Cited by 48
Park, Y. W., Ahn, S. S., Park, C. J., Han, K., Kim, E. H., Kang, S., Chang, J. H., Kim, S. H., & Lee, S. (2020) · European Radiology · doi:10.1007/s00330-020-07090-3 · Cited by 49
Carota, F., Nili, H., Friedemann Pulvermüller, A., & Kriegeskorte, N. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117408 · Cited by 51
Fujioka, C., Horiguchi, J., Ishifuro, M., Kakizawa, H., Kiguchi, M., Matsuura, N., Hieda, M., Tachikake, T., Alam, F., Furukawa, T., et al. (2006) · Academic Radiology · doi:10.1016/j.acra.2006.05.011 · Cited by 48
Sdika, M. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.12.004 · Cited by 48
Tripoliti, E. E., Fotiadis, D. I., & Argyropoulou, M. I. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.005 · Cited by 49
The blood vessel recognition of ocular fundus
Xu, Z., Guo, X., Hu, X., & Cheng, X. (2005) · International Conference on Machine Learning and Cybernetics · doi:10.1109/icmlc.2005.1527730 · Cited by 48
Robust Estimation for Brain Tumor Segmentation
Prastawa, M. W., Bullitt, E., Ho, S., & Gerig, G. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39903-2_65 · Cited by 48
A classification based similarity metric for 3D image retrieval
Liu, Y., & Dellaert, F. (2002) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1998.698695 · Cited by 48
From error probability to information theoretic (multi-modal) signal processing
Butz, T., & Thiran, J. (2005) · Signal Processing · doi:10.1016/j.sigpro.2004.11.027 · Cited by 48
Brain Vascular Damage of Cholinergic Pathways and EEG Markers in Mild Cognitive Impairment
Moretti, D. V., Pievani, M., Fracassi, C., Geroldi, C., Calabria, M., DeCarli, C. S., Rossini, P. M., & Frisoni, G. B. (2008) · Journal of Alzheimer s Disease · doi:10.3233/jad-2008-15302 · Cited by 47
Hoptman, M. J., Volavka, J., Czobor, P., Gerig, G., Chakos, M., Blocher, J., Citrome, L., Sheitman, B., Lindenmayer, J., Lieberman, J. A., et al. (2006) · Journal of Neuropsychiatry · doi:10.1176/appi.neuropsych.18.4.509 · Cited by 47
Sky segmentation with ultraviolet images can be used for navigation
Stone, T., Mangan, M., Ardin, P., & Webb, B. H. (2014) · Robotics: Science and Systems · doi:10.15607/rss.2014.x.047 · Cited by 47
Stalder, A. K., Ilgenstein, B., Chicherova, N., Deyhle, H., Beckmann, F., Müller, B., & Hieber, S. E. (2014) · International Journal of Materials Research (formerly Zeitschrift fuer Metallkunde) · doi:10.3139/146.111050 · Cited by 47
Tsai, J., Peng, S., Chen, Y., Wang, K.-W., Li, C.-H., Wang, J. Y., Chen, C.-J., Lin, H.-J., Smith, E. E., Wu, H.-K., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104011 · Cited by 47
Zald, D. H., Woodward, N. D., Cowan, R. L., Riccardi, P., Ansari, M. S., Baldwin, R. M., Cowan, R. L., Smith, C. E., Hakyemez, H., Li, R., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.006 · Cited by 47
Personalized Dosimetry for Radionuclide Therapy Using Molecular Imaging Tools
Ljungberg, M. H., & Gleisner, K. S. (2016) · Biomedicines · doi:10.3390/biomedicines4040025 · Cited by 47
A multimodal computational pipeline for 3D histology of the human brain
Mancini, M., Casamitjana, A., Peter, L., Robinson, E., Crampsie, S., Thomas, D. L., Holton, J. L., Jaunmuktane, Z., & Iglesias, J. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-69163-z · Cited by 50
Unaligned Hyperspectral Image Fusion via Registration and Interpolation Modeling
Ying, J., Shen, H., & Cao, S.-Y. (2021) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2021.3081136 · Cited by 47
Construction and Validation of Mean Shape Atlas Templates for Atlas-Based Brain Image Segmentation
Wang, Q., Seghers, D., D’Agostino, E., Maes, F., Vandermeulen, D., Suetens, P., & Hammers, A. (2005) · Lecture notes in computer science · doi:10.1007/11505730_57 · Cited by 47
Self-citationWalimbe, V., & Shekhar, R. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.09.002 · Cited by 47
Optimizing SPECT SISCOM analysis to localize seizure‐onset zone by using varying z scores
Newey, C. R., Wong, C., Wang, Z. I., Chen, X., Wu, G., & Alexopoulos, A. V. (2013) · Epilepsia · doi:10.1111/epi.12139 · Cited by 47
Cortical theta wanes for language
Hermes, D., Miller, K. J., Vansteensel, M. J., Edwards, E., Ferrier, C. H., Bleichner, M. G., van Rijen, P. C., Aarnoutse, E. J., & Ramsey, N. F. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.029 · Cited by 51
Okane, K., Ibaraki, M., Toyoshima, H., Sugawara, S., Takahashi, K., Miura, S., Shimosegawa, E., Satomi, J., Kitamura, K., & Satoh, T. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-0005-2 · Cited by 47
Hammers, A., Asselin, M., Turkheimer, F., Hinz, R., Osman, S., Hotton, G. R., Brooks, D. J., Duncan, J. S., & Koepp, M. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.06.035 · Cited by 47
Nonextensive information-theoretic measure for image edge detection
Hamza, A. B. (2006) · Journal of Electronic Imaging · doi:10.1117/1.2177638 · Cited by 47
Image registration using the Walsh transform
Lazaridis, G., & Πέτρου, Μ. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.877346 · Cited by 47
The use of mutual information in registration of CT and MRI datasets post permanent implant
McLaughlin, P. W., Narayana, V., Kessler, M. L., McShan, D. L., Troyer, S., Marsh, L. H., Hixson, G. V., & Roberson, P. L. (2004) · Brachytherapy · doi:10.1016/j.brachy.2004.06.001 · Cited by 47
Anatomically informed interpolation of fMRI data on the cortical surface
Grova, C., Makni, S., Flandin, G., Ciuciu, P., Gotman, J., & Poline, J.-B. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.049 · Cited by 47
Affine Coregistration of Diffusion Tensor Magnetic Resonance Images Using Mutual Information
Leemans, A., Sijbers, J., Backer, S. D., Vandervliet, E. J. M., & Parizel, P. M. (2005) · Lecture notes in computer science · doi:10.1007/11558484_66 · Cited by 47
A Data Fusion Environment for Multimodal and Multi-Informational Neuronavigation
Jannin, P., Fleig, O. J., Seigneuret, É., Grova, C., Morandi, X., & Scarabin, J. (2000) · Computer Aided Surgery · doi:10.1002/(sici)1097-0150(2000)5:1 · Cited by 47
Multi-Modal Medical Image Registration with Full or Partial Data: A Manifold Learning Approach
Bashiri, F. S., Baghaie, A., Rostami, R., Yu, Z., & D’Souza, R. M. (2018) · Journal of Imaging · doi:10.3390/jimaging5010005 · Cited by 46
Generalizing Spatial Transformers to Projective Geometry with Applications to 2D/3D Registration
Gao, C., Liu, X., Gu, W., Killeen, B., Armand, M., Taylor, R., & Unberath, M. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-59716-0_32 · Cited by 46
Kim, S., Feng, L., Grimm, R., Freed, M. E., Block, K. T., Sodickson, D. K., Moy, L. P., & Otazo, R. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24961 · Cited by 46
Diffusion-weighted versus volumetric imaging of the striatum in early symptomatic Huntington disease
Vandenberghe, W., Demaerel, P., Dom, R., & Maes, F. (2009) · Journal of Neurology · doi:10.1007/s00415-009-0086-0 · Cited by 46
Self-citationFat-mass-related hormone, plasma leptin, predicts brain volumes in the elderly
Rajagopalan, P., Toga, A. W., Jack, C. R., Weiner, M. W., & Thompson, P. M. (2012) · Neuroreport · doi:10.1097/wnr.0b013e32835c5254 · Cited by 46
Hasan, M. M., Pickering, M. R., & Jia, X. (2012) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2012.2187456 · Cited by 46
An information-theoretic method for multimodality medical image registration
Khader, M., & Hamza, A. B. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.11.064 · Cited by 46
Fei, B., Wang, H., Muzic, R. F., Flask, C. A., Wilson, D. L., Duerk, J. L., Feyes, D. K., & Oleinick, N. L. (2006) · Medical Physics · doi:10.1118/1.2163831 · Cited by 46
Image registration using robust M-estimators
Arya, K. V., Gupta, P., Kalra, P. K., & Mitra, P. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2007.05.006 · Cited by 46
Zuiderveld, E. G., van Nimwegen, W. G., Meijer, H. J. A., Jung, R. E., Mühlemann, S., Vissink, A., & Raghoebar, G. M. (2020) · Journal of Periodontology · doi:10.1002/jper.20-0217 · Cited by 46
Integrated registration and visualization of medical image data
Hastreiter, P., & Ertl, T. (2002) · Computer Graphics International · doi:10.1109/cgi.1998.694253 · Cited by 46
Brain Atlas Deformation in the Presence of Small and Large Space-Occupying Tumors
Dawant, B. M., Hartmann, S. L., Pan, S., & Gadamsetty, S. (2002) · Computer Aided Surgery · doi:10.1002/igs.10029 · Cited by 46
Groupwise registration based on hierarchical image clustering and atlas synthesis
Wang, Q., Chen, L., Yap, P., Guorong Wu, A., & Shen, D. G. (2010) · Human Brain Mapping · doi:10.1002/hbm.20923 · Cited by 46
Striatal Dopamine Release and Family History of Alcoholism
Munro, C. A., McCaul, M. E., Oswald, L. M., Wong, D. F., Zhou, Y., Brašić, J. R., Kuwabara, H., Kumar, A., Alexander, M., Ye, W., et al. (2006) · Alcoholism Clinical and Experimental Research · doi:10.1111/j.1530-0277.2006.00130.x · Cited by 47
Registration, segmentation, and visualization of multimodal brain images
Viergever, M. A., Maintz, J. B. A., Niessen, W. J., Noordmans, H. J., Pluim, J. P. W., Stokking, R., & Vincken, K. L. (2001) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(00)00065-3 · Cited by 46
A probabilistic histological atlas of the human brain for MRI segmentation
Casamitjana, A., Mancini, M., Robinson, E., Peter, L., Annunziata, R., Althonayan, J. I. M., Crampsie, S., Blackburn, E., Billot, B., Atzeni, A., et al. (2025) · Nature · doi:10.1038/s41586-025-09708-2 · Cited by 45
Zheng, B., Mello-Thoms, C. R., Wang, X.-H., Abrams, G. S., Sumkin, J. H., Chough, D. M., Ganott, M. A., Lu, A. H., & Gur, D. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.04.012 · Cited by 45
Estimation of mutual information using copula density function
Zeng, X., & Durrani, T. S. (2011) · Electronics Letters · doi:10.1049/el.2011.0778 · Cited by 45
An enhanced block matching algorithm for fast elastic registration in adaptive radiotherapy
Malsch, U., Thieke, C., Huber, P. E., & Bendl, R. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/19/005 · Cited by 45
Does having a twin brother make for a bigger brain?
Peper, J. S., Brouwer, R. M., van Baal, G. C. M., Schnack, H. G., van Leeuwen, M., Boomsma, D. I., Kahn, R. S., & Pol, H. E. H. (2009) · European Journal of Endocrinology · doi:10.1530/eje-08-0915 · Cited by 45
Abela, E., Seiler, A., Missimer, J. H., Federspiel, A., Hess, C. W., Sturzenegger, M., Weder, B., & Wiest, R. (2014) · Brain Structure and Function · doi:10.1007/s00429-014-0804-y · Cited by 46
Arora, B., Dwivedi, D., Hubbard, S. S., Steefel, C. I., & Williams, K. H. (2016) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2016.08.005 · Cited by 45
Multimodal medical image registration using Particle Swarm Optimization: A review
Rundo, L., Tangherloni, A., Militello, C., Gilardi, M. C., & Mauri, G. (2016) · IEEE Symposium Series on Computational Intelligence (SSCI) · doi:10.1109/ssci.2016.7850261 · Cited by 48
Achievability of 3D planned bimaxillary osteotomies: maxilla-first versus mandible-first surgery
Liebregts, J., Baan, F., de Koning, M. J. J., Ongkosuwito, E. M., Bergé, S. J., Maal, T., & Xi, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-09488-4 · Cited by 45
Lee, B. C., Moody, J. B., Poitrasson-Rivière, A., Melvin, A. C., Weinberg, R. L., Corbett, J. R., Murthy, V. L., & Ficaro, E. P. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-01471-4 · Cited by 45
Gil, A. P. S., Guijarro‐Martínez, R., Haas, O. L., & Hernández-Alfaro, F. J. (2019) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2019.01.028 · Cited by 45
A Unifying Framework for Mutual Information Methods for Use in Non-linear Optimisation
Dowson, N., & Bowden, R. (2006) · Lecture notes in computer science · doi:10.1007/11744023_29 · Cited by 45
Olfactory loss and nigrostriatal dopaminergic denervation in the elderly
Wong, K. K., Müller, M. L. T. M., Kuwabara, H., Studenski, S. A., & Bohnen, N. I. (2010) · Neuroscience Letters · doi:10.1016/j.neulet.2010.08.037 · Cited by 45
Virtual circles: a new set of features for fast image registration
Alhichri, H. S., & Kamel, M. S. (2003) · Pattern Recognition Letters · doi:10.1016/s0167-8655(02)00300-8 · Cited by 45
DEBRUIN, E., Pol, H. E. H., Schnack, H. G., Janssen, J., Bijl, S., EVANS, A., Kenemans, J. L., Kahn, R. S., & Verbaten, M. N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.036 · Cited by 45
Isotropic 3D fast FLAIR imaging of the brain in multiple sclerosis patients: initial experience
Tan, I. L., Pouwels, P. J. W., van Schijndel, R. A., Adèr, H. J., Manoliu, R. A., & Barkhof, F. (2002) · European Radiology · doi:10.1007/s00330-001-1170-8 · Cited by 45
Bragulat, V., Martinot, M. P., Artiges, É., Frouin, V., Poline, J., & Martinot, J. (2007) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2006.07.002 · Cited by 49
Clinical Evaluation of Targeting Accuracy of Gamma Knife Radiosurgery in Trigeminal Neuralgia
Massager, N., Abeloos, L., Devriendt, D., Beeck, M. O. D., & Levivier, M. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.05.013 · Cited by 45
Dandekar, O. S., & Shekhar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.909023 · Cited by 45
Validation of fully automatic brain SPET to MR co-registration
Barnden, L. R., Kwiatek, R., Lau, Y., Hutton, B. F., Thurfjell, L., Pile, K. D., & Rowe, C. C. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050020 · Cited by 45
Hill, D., Maurer, C. R., Studholme, C., Fitzpatrick, J. M., & Hawkes, D. J. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199803000-00031 · Cited by 45
GLS–MIFT: A modality invariant feature transform with global-to-local searching
Fan, Z., Pi, Y., Wang, M., Kang, Y., & Tan, K. (2024) · Information Fusion · doi:10.1016/j.inffus.2024.102252 · Cited by 44
Differential association of [ 11 C]PIB and [ 18 F]FDDNP binding with cognitive impairment
Tolboom, N., van der Flier, W. M., Yaqub, M. M., Koene, T., Boellaard, R., Windhorst, A. D., Scheltens, P., Lammertsma, A. A., & van Berckel, B. N. M. (2009) · Neurology · doi:10.1212/wnl.0b013e3181c679cc · Cited by 44
Shi, L., Wang, D., Liu, S., Pu, Y., Wang, Y., Chu, C. W., Ahuja, A. T., & Wang, Y. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.12.014 · Cited by 44
A genetic analysis of brain volumes and IQ in children
van Leeuwen, M., Peper, J. S., van den Berg, S. M., Brouwer, R. M., Pol, H. E. H., Kahn, R. S., & Boomsma, D. I. (2008) · Intelligence · doi:10.1016/j.intell.2008.10.005 · Cited by 45
Review Article: An Overview of Template Matching Technique in Image Processing
Mahalakshmi, T., Muthaiah, R., & Swaminathan, P. (2012) · Research Journal of Applied Sciences Engineering and Technology · Cited by 44
Multimodal characterization of the human nucleus accumbens
Cartmell, S. C. D., Tian, Q., Thio, B. J., Leuze, C. W., Li, Y., Williams, N., Yang, G., Ben-Dor, G. A., Deisseroth, K. A., Grill, W. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.019 · Cited by 44
Reda, F. A., McRackan, T. R., Labadie, R. F., Dawant, B. M., & Noble, J. H. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.02.001 · Cited by 44
Feuerstein, M., Glocker, B., Kitasaka, T., Nakamura, Y., Iwano, S., & Mori, K. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.05.005 · Cited by 43
Metadata
- Authors
- Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P.
- Affiliations
- KU Leuven (BE)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 187-198
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2034432063
- Cited by
- 4,547
- References
- 30
- Citations by year
- 2026: 80 · 2025: 84 · 2024: 93 · 2023: 85 · 2022: 116 · 2021: 130 · 2020: 121 · 2019: 124 · 2018: 171 · 2017: 153 · 2016: 139 · 2015: 183 · 2014: 195 · 2013: 212 · 2012: 209
- FWCI
- 71.00
- Type
- journal article
- Language
- en
- Open access
- green
- lirias.kuleuven.be
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- multimodal image registration, mutual information, rigid registration, Kullback-Leibler divergence, partial overlap, image degradation
- MeSH terms
- Algorithms, Brain, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›