The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Multimodality image registration by maximization of mutual information
Open accessAbstract
A new approach to the problem of multimodality medical image registration is proposed, using a basic concept from information theory, mutual information (MI), or relative entropy, as a new matching criterion. The method presented in this paper applies MI to measure the statistical dependence or information redundancy between the image intensities of corresponding voxels in both images, which is assumed to be maximal if the images are geometrically aligned. Maximization of MI is a very general and powerful criterion, because no assumptions are made regarding the nature of this dependence and no limiting constraints are imposed on the image content of the modalities involved. The accuracy of the MI criterion is validated for rigid body registration of computed tomography (CT), magnetic resonance (MR), and photon emission tomography (PET) images by comparison with the stereotactic registration solution, while robustness is evaluated with respect to implementation issues, such as interpolation and optimization, and image content, including partial overlap and image degradation. Our results demonstrate that subvoxel accuracy with respect to the stereotactic reference solution can be achieved completely automatically and without any prior segmentation, feature extraction, or other preprocessing steps which makes this method very well suited for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A 2D intraoperative X-ray can be registered to a 3D preoperative CT volume by maximizing its similarity to a rendered X-ray with respect to the camera pose [8, 14, 34].”
From Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering (2024) · cites this paper as [34]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions.”
From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While these metrics are positively correlated with pose differences when the perturbations in {K^v,T^xv,ω^D} are small, they are generally non-convex and fail to accurately represent pose offsets when perturbations are large.”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Conventional intensity-based methods mostly use hand-crafted similarity metrics between y v and its current best estimate y^v=(P(Kv,Txv)◦DωD)(x)fx1 as loss function. Common choices for the similarity metric are Normalized Cross Correlation (NCC), gradient information (Berger et al., 2016), or Mutual Information (MI) (Maes et al., 1997).”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 37,139
Pattern classification and scene analysis
Grenander, U., Duda, R., & Hart, P. (1974) · A Wiley-Interscience publication · doi:10.2307/1573081 · Cited by 17,399
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 12,040
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,079
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P. A., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,961
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & Cherry, A. S. R. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,636
Alignment by maximization of mutual information
Viola, P. A., & Wells, W. M. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.1995.466930 · Cited by 1,080
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 883
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Collignon, A. M. F., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534053 · Cited by 809
Self-citation
Flagged first, then by citations
Research works printed but not linked: 6
- fitzpatrick, 1994, Evaluation of retrospective image registration
- press, 1992, Numerical Recipes in C, 412
- collignon, 1995, automated multimodality medical image registration using information theory, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 263
- baddeley, 1992, an error metric for binary images, Proc IEEE Workshop on Robust Computer Vision, 59
- astola, 1982, entropy correlation coefficient, a measure of statistical dependence for categorized data, Proc Univ Vaasa Discussion Papers
- studholme, 1995, multiresolution voxel similarity measures for mr-pet registration, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 287
Cited by
Sorted by citations
Items 801–900 of 1,006
A minimum description length objective function for groupwise non-rigid image registration
Marsland, S., Twining, C., & Taylor, C. (2006) · Image and Vision Computing · doi:10.1016/j.imavis.2006.12.009 · Cited by 57
Noble, J. H., & Dawant, B. M. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.05.001 · Cited by 58
A Versatile Functional–Anatomic Image Fusion Method for Volume Data Sets
Noz, M. E., Maguire, G. Q., Zeleznik, M. P., KRAMER, E. L., Mahmoud, F., & Crafoord, J. (2001) · Journal of Medical Systems · doi:10.1023/a:1010633123512 · Cited by 57
van Herk, M., de Munck, J. C., Lebesque, J. V., Muller, S. H., Rasch, C. R. N., & Touw, A. (1998) · Medical Physics · doi:10.1118/1.598393 · Cited by 57
Dong, S., Yang, Q., Fu, Y., Tian, M., & Zhuo, C. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2021.3086570 · Cited by 56
Lanthanide nanoparticles for near-infrared II theranostics
Jia, T., & Chen, G. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214724 · Cited by 56
Comparison of Plasma Input and Reference Tissue Models for Analysing [ 11 C]flumazenil Studies
Klumpers, U. M. H., Veltman, D. J., Boellaard, R., Comans, E. F. I., Zuketto, C., Yaqub, M. M., Mourik, J. E. M., Lubberink, M., Hoogendijk, W. J. G., & Lammertsma, A. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600554 · Cited by 56
Kropholler, M. A., Boellaard, R., van Berckel, B. N. M., Schuitemaker, A., Kloet, R. W., Lubberink, M., Jonker, C., Scheltens, P., & Lammertsma, A. A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600488 · Cited by 56
Nishiyama, K. K., Campbell, G. M., Klinck, R. J., & Boyd, S. K. (2009) · Bone · doi:10.1016/j.bone.2009.09.023 · Cited by 56
Lebenberg, J., Hérard, A., Dubois, A., Dauguet, J., Frouin, V., Dhénain, M., Hantraye, P., & Delzescaux, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.014 · Cited by 56
Scheys, L., Loeckx, D., Spaepen, A. J., Suetens, P., & Jonkers, I. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.12.014 · Cited by 56
Self-citationGGO Nodule Volume-Preserving Nonrigid Lung Registration Using GLCM Texture Analysis
Park, S., Kim, B., Lee, J., Goo, J. M., & Shin, Y.-G. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2162330 · Cited by 56
Mazurowski, M. A., Lo, J. Y.-C., Harrawood, B. P., & Tourassi, G. D. (2011) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2011.04.008 · Cited by 56
Image registration with minimum spanning tree algorithm
Ma, B., Hero, A. O., Gorman, J., & Michel, O. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2000.901000 · Cited by 56
Zhu, Y., & Cochoff, S. M. (2002) · PubMed · Cited by 56
Andrei Irimia, A., Chambers, M. C., Alger, J. R., Filippou-Frye, M., Prastawa, M. W., Wang, B., Hovda, D. A., Gerig, G., Toga, A. W., Kikinis, R., et al. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2011.1920 · Cited by 56
de Waard, O., Baan, F., Verhamme, L. M., Breuning, H., Kuijpers‐Jagtman, A. M., & Maal, T. (2015) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2015.11.017 · Cited by 56
State-of-the-Art Medical Image Registration Methodologies: A Survey
Khalifa, F., Beache, G. M., Gimel’farb, G., Suri, J. S., & El-Baz, A. S. (2011) · Springer eBooks · doi:10.1007/978-1-4419-8195-0_9 · Cited by 56
Elastic registration of fMRI data using Bezier-spline transformations
Otte, M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.918470 · Cited by 56
Principles and Applications of Computer Graphics in Medicine
Vidal, F. P., Bello, F., Brodlie, K., John, N. W., Gould, D., Phillips, R., & Avis, N. J. (2006) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2006.00822.x · Cited by 56
Moddemeijer, R. (1999) · Signal Processing · doi:10.1016/s0165-1684(98)00224-2 · Cited by 56
An efficient mutual information optimizer for multiresolution image registration
Thévenaz, P., & Unser, M. A. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1998.723645 · Cited by 56
Nonrigid registration method to assess reproducibility of breath-holding with ABC in lung cancer
Sarrut, D., Boldea, V., Ayadi, M., Badel, J., Ginestet, C., Clippe, S., & Carrié, C. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.007 · Cited by 56
Liao, R., Krolik, J. L., & McKeown, M. J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.837791 · Cited by 56
Nikou, C., Heitz, F., Armspach, J., Namer, I. J., & Grucker, D. (1998) · NeuroImage · doi:10.1006/nimg.1998.0335 · Cited by 56
PET measurement of serotonin transporter occupancy: a comparison of escitalopram and citalopram
Lundberg, J., Christophersen, J. S., Petersen, K. B., Loft, H., Halldin, C., & Farde, L. (2007) · The International Journal of Neuropsychopharmacology · doi:10.1017/s1461145706007486 · Cited by 55
Monomodal image registration using mutual information based methods
Gao, Z., Gu, B., & Lin, J. (2006) · Image and Vision Computing · doi:10.1016/j.imavis.2006.08.002 · Cited by 55
Extended three-dimensional impedance map methods for identifying ultrasonic scattering sites
Mamou, J., Oelze, M. L., O’Brien, W. D., & Zachary, J. F. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2822658 · Cited by 55
A New Method of Detecting Pulmonary Nodules with PET/CT Based on an Improved Watershed Algorithm
Zhao, J., Ji, G., Qiang, Y., Han, X., Pei, B., & Shi, Z. (2015) · PLoS ONE · doi:10.1371/journal.pone.0123694 · Cited by 55
A unified framework for cross-modality multi-atlas segmentation of brain MRI
Iglesias, J. E., Sabuncu, M. R., & Leemput, K. V. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.08.001 · Cited by 55
Retrospective evaluation of a topology preserving non-rigid registration method
Noblet, V., Heinrich, C., Heitz, F., & Armspach, J. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.01.001 · Cited by 55
The mixtures of Student’s t-distributions as a robust framework for rigid registration
Gerogiannis, D. P., Nikou, C., & Likas, A. C. (2008) · Image and Vision Computing · doi:10.1016/j.imavis.2008.11.013 · Cited by 55
Age-associated leukoaraiosis and cortical cholinergic deafferentation
Bohnen, N. I., Müller, M. L. T. M., Kuwabara, H., Constantine, G. M., & Studenski, S. A. (2009) · Neurology · doi:10.1212/wnl.0b013e3181a187c6 · Cited by 55
Vascular image registration techniques: A living review
Matl, S., Brosig, R., Baust, M., Navab, N., & Demirci, S. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.05.005 · Cited by 55
Ultrasound registration: A review
Che, C., Mathai, T. S., & Galeotti, J. (2016) · Methods · doi:10.1016/j.ymeth.2016.12.006 · Cited by 55
Diehl, B., LaPresto, E., Najm, I., Raja, S., Rona, S., Babb, T. L., Ying, Z., Bingaman, W. E., Lüders, H. O., & Ruggieri, P. M. (2003) · Epilepsia · doi:10.1046/j.1528-1157.2003.36202.x · Cited by 55
Imaging and Alignment for Image-Guided Radiation Therapy
Balter, J. M., & Kessler, M. L. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.7998 · Cited by 55
Humm, J. L., Ballon, D., Hu, Y., Ruan, S., Chui, C. S., Tulipano, P. K., Erdi, A. K., Koutcher, J. A., Zakian, K. L., Urano, M., et al. (2003) · Medical Physics · doi:10.1118/1.1600738 · Cited by 55
Buyyounouski, M. K., Horwitz, E. M., Price, R., Hanlon, A. L., Uzzo, R. G., & Pollack, A. S. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)01617-1 · Cited by 55
Registration of Real-Time 3-D Ultrasound Images of the Heart for Novel 3-D Stress Echocardiography
Shekhar, R., Zagrodsky, V., Garcia, M. J., & Thomas, J. D. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.830527 · Cited by 55
Glocker, B., Nikos Komodakis, A., Nikos Paragios, A., Tziritas, G., & Navab, N. (2007) · Lecture notes in computer science · doi:10.1007/978-3-540-73273-0_34 · Cited by 55
Berding, G., Müller-Vahl, K., Schneider, U., Gielow, P., Fitschen, J., Stuhrmann, M., Harke, H., Buchert, R., Donnerstag, F., Hofmann, M., et al. (2004) · Biological Psychiatry · doi:10.1016/j.biopsych.2004.01.005 · Cited by 54
Automatic SAR Image Registration via Tsallis Entropy and Iterative Search Process
Kang, M., & Kim, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2981398 · Cited by 54
Rougon, N. F., Petitjean, C., Preteux, F. J., Cluzel, P., & Greniér, P. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.01.005 · Cited by 54
Karabanov, A. N., Červenka, S., de Manzano, Ö., Forssberg, H., Farde, L., & Ullén, F. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911805107 · Cited by 54
Charil, A., Corbo, M., Filippi, M., Kesavadas, C., Agosta, F., Munerati, E., Gambini, A., Comı, G., Scotti, G., & Falini, A. (2009) · Amyotrophic Lateral Sclerosis · doi:10.1080/17482960902777339 · Cited by 54
Performance bounds on image registration
Yetik, İ. Ş., & Nehorai, A. (2006) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2006.870552 · Cited by 54
EzEldeen, M., Stratis, A., Coucke, W., Codari, M., Politis, C., & Jacobs, R. (2016) · Journal of Endodontics · doi:10.1016/j.joen.2016.10.022 · Cited by 54
Saha, S., Xiao, D., Bhuiyan, A., Wong, T. Y., & Kanagasingam, Y. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.08.034 · Cited by 54
Blendowski, M., Hansen, L., & Heinrich, M. P. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101822 · Cited by 54
Poyot, T., Condé, F., Grégoire, M., Frouin, V., Coulon, C., Fuseau, C., Hinnen, F., Dollé, F., Hantraye, P., & Bottlaender, M. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200107000-00003 · Cited by 54
Rigid Registration of Freehand 3D Ultrasound and CT-Scan Kidney Images
Leroy, A., Mozer, P., Yohan Payan, A., & Troccaz, J. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30135-6_102 · Cited by 53
Hecke, W. V., Sijbers, J., Backer, S. D., Poot, D. H. J., Parizel, P. M., & Leemans, A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.032 · Cited by 54
A clinically relevant validation method for implant placement after virtual planning
Verhamme, L. M., Meijer, G. J., Boumans, T., Schutyser, F., Bergé, S. J., & Maal, T. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2012.02565.x · Cited by 53
Ribbens, A., Hermans, J., Maes, F., Vandermeulen, D., & Suetens, P. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2270114 · Cited by 55
Self-citationInvertibility and transitivity analysis for nonrigid image registration
Christensen, G. E., & Johnson, H. J. (2003) · Journal of Electronic Imaging · doi:10.1117/1.1526494 · Cited by 53
Castro, F. J. S., Pollo, C., Meuli, R. A., Maeder, P. P., Cuisenaire, O., Cuadra, M. B., Villemure, J., & Thiran, J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882129 · Cited by 54
Lee, J. Y., Kim, J. W., Lee, J., Lim, Y. H., Kim, C., Kim, D. G., Jeon, B. S., & Paek, S. H. (2010) · Acta Neurochirurgica · doi:10.1007/s00701-010-0779-2 · Cited by 53
Elastic registration of electrophoresis images using intensity information and point landmarks
Rohr, K., Cathier, P., & Wörz, S. (2004) · Pattern Recognition · doi:10.1016/j.patcog.2003.10.004 · Cited by 53
Studholme, C., Cardenas, V. A., Song, E., Ezekiel, F., Maudsley, A. A., & Weiner, M. W. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820029 · Cited by 53
Hybrid Image Registration based on Configural Matching of Scale-Invariant Salient Region Features
Huang, X., Sun, Y., Metaxas, D., Sauer, F., & Xu, C. (2005) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvpr.2004.362 · Cited by 53
Correction of Motion Artifact in Cardiac Optical Mapping Using Image Registration
Rohde, G. K., Dawant, B. M., & Lin, S. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840464 · Cited by 53
Multimodal Remote Sensing Image Matching Based on Weighted Structure Saliency Feature
Wan, G., Ye, Z., Xu, Y., Huang, R., Zhou, Y., Xie, H., & Tong, X. (2023) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2023.3347259 · Cited by 52
Tiehuis, A. M., Vincken, K. L., Mali, W. P. T. M., Kappelle, L. J., Anbeek, P., Algra, A., & Biessels, G. J. (2007) · Cerebrovascular Diseases · doi:10.1159/000111500 · Cited by 52
Effective packet number for early stage internet traffic identification
Peng, L., Yang, B., & Chen, Y. (2015) · Neurocomputing · doi:10.1016/j.neucom.2014.12.053 · Cited by 52
Tissue-Based MRI Intensity Standardization: Application to Multicentric Datasets
Robitaille, N., Mouiha, A., Crépeault, B., Valdivia, F., Duchesne, S., & Initiative, T. A. D. N. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/347120 · Cited by 52
Gaudeau-Bosma, C., Moulier, V., Allard, A.-C., Sidhoumi, D., Bouaziz, N., Braha, S., Volle, E., & Januel, D. (2012) · Brain stimulation · doi:10.1016/j.brs.2012.10.009 · Cited by 57
Sun, Y., Lübbers, H., Agbaje, J. O., Schepers, S., Politis, C., Slycke, S. V., & Vrielinck, L. J. G. (2013) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12189 · Cited by 52
FAIR: a hardware architecture for real-time 3-D image registration
Castro‐Pareja, C. R., Jagadeesh, J. M., & Shekhar, R. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.821370 · Cited by 52
Reinartz, P., Kaiser, H.-J., Wildberger, J. E., Gordji, C., Nowak, B., & Buell, U. (2006) · PubMed · Cited by 52
Rapid registration for wide field of view freehand three-dimensional ultrasound
Gee, A. H., Treece, G. M., Prager, R. W., Cash, C. J. C., & Berman, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819279 · Cited by 52
Zhuang, Y., Gao, K., Miu, X.-H., Han, L., & Gong, X. (2015) · Optik · doi:10.1016/j.ijleo.2015.09.199 · Cited by 51
Processing and visualizing three-dimensional ultrasound data
Gee, A. H., Prager, R. W., Treece, G. M., Cash, C. J. C., & Berman, L. (2004) · British Journal of Radiology · doi:10.1259/bjr/80676194 · Cited by 51
Feasibility of Multimodal Deformable Registration for Head and Neck Tumor Treatment Planning
Fortunati, V., Verhaart, R. F., Angeloni, F., van der Lugt, A., Niessen, W. J., Veenland, J. F., Paulides, M. M., & van Walsum, T. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.05.027 · Cited by 51
Linear intensity-based image registration by Markov random fields and discrete optimization
Zikic, D., Glocker, B., Kutter, O., Groher, M., Nikos Komodakis, A., Kamen, A., Nikos Paragios, A., & Navab, N. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.04.003 · Cited by 51
A method for the alignment of heterogeneous macromolecules from electron microscopy
Shatsky, M., Hall, R. J., Brenner, S. E., & Glaeser, R. M. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.12.008 · Cited by 51
Fast Automatic Step Size Estimation for Gradient Descent Optimization of Image Registration
Qiao, Y., van Lew, B., Lelieveldt, B. P. F., & Staring, M. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2476354 · Cited by 51
Chen, S., Li, X., Zhao, L., & Yang, H. (2018) · International Journal of Remote Sensing · doi:10.1080/01431161.2018.1437295 · Cited by 51
A Review of Deformation Models in Medical Image Registration
Wang, M., & Li, P. (2018) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-018-0390-1 · Cited by 51
Meng, H., Wang, K., Gao, Y., Jin, Y., Ma, X., & Tian, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2912222 · Cited by 51
Virtually planned and template-guided implant surgery: an experimental model matching approach
Komiyama, A., Pettersson, A., Hultin, M., Näsström, K., & Klinge, B. (2010) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02001.x · Cited by 51
Impact of FDG-PET/MRI Image Fusion on the Detection of Pancreatic Cancer
Ruf, J., HÄNNINEN, E. L., Böhmig, M., Koch, I., Denecke, T., Plotkin, M., Langrehr, J. M., Wiedenmann, B. J., FELIX, R., & Amthauer, H. (2006) · Pancreatology · doi:10.1159/000096993 · Cited by 51
Taylor, W. D., Zhao, Z., Ashley‐Koch, A., Payne, M. E., Steffens, D. C., Krishnan, R. R., Hauser, E., & MacFall, J. R. (2013) · Human Brain Mapping · doi:10.1002/hbm.21445 · Cited by 50
Meschi, N., EzEldeen, M., Torres, A., Lahoud, P., Gorp, G. V., Coucke, W., Jacobs, R., Vandamme, K., Teughels, W., & Lambrechts, P. (2021) · Journal of Endodontics · doi:10.1016/j.joen.2021.08.003 · Cited by 50
Non-rigid image registration of brain magnetic resonance images using graph-cuts
So, R. W. K., Tang, T. W. H., & Chung, A. C. S. (2011) · Pattern Recognition · doi:10.1016/j.patcog.2011.04.008 · Cited by 50
Genetic and environmental influences on focal brain density in bipolar disorder
van der Schot, A. C., Vonk, R., Brouwer, R. M., van Baal, G. C. M., Brans, R. G. H., van Haren, N. E. M., Schnack, H. G., Boomsma, D. I., Nolen, W. A., Pol, H. E. H., et al. (2010) · Brain · doi:10.1093/brain/awq236 · Cited by 51
Rummel, C., Abela, E., Andrzejak, R. G., Hauf, M., Pollo, C., Müller, M., Weisstanner, C., Wiest, R., & Schindler, K. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0141023 · Cited by 51
Reimer, C., Deike‐Hofmann, K., Graf, M., Reimer, P., Wiestler, B., Floca, R. O., Kickingereder, P., Schlemmer, H.-P., Wick, W., Bendszus, M., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174620 · Cited by 50
Sauwen, N., Acou, M., Sima, D. M., Veraart, J., Maes, F., Himmelreich, U., Achten, E., & Huffel, S. V. (2017) · BMC Medical Imaging · doi:10.1186/s12880-017-0198-4 · Cited by 50
Self-citationGao, Y., Wang, K., Jiang, S., Liu, Y., Ai, T., & Tian, J. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2737661 · Cited by 50
Matching Pixels Using Co-occurrence Statistics
Kat, R., Jevnisek, R. J., & Avidan, S. (2018) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2018.00188 · Cited by 50
A Low Dimensional Fluid Motion Estimator
Cuzol, A., Pierre Hellier, J., & Mémin, É. (2007) · International Journal of Computer Vision · doi:10.1007/s11263-007-0037-0 · Cited by 50
Sanjay‐Gopal, S., Chan, H., Wilson, T. M., Helvie, M. A., Petrick, N., & Sahiner, B. (1999) · Medical Physics · doi:10.1118/1.598806 · Cited by 50
3D Ultrasound Imaging of the Carotid Arteries
Fenster, A., Landry, A., Downey, D. B., Hegele, R. A., & Spence, J. D. (2004) · Cardiovascular & Haematological Disorders - Drug Targets · doi:10.2174/1568006043336311 · Cited by 50
Twin–singleton differences in brain structure using structural equation modelling
Pol, H. E. H., Posthuma, D., Baaré, W. F. C., de Geus, E. J. C., Schnack, H. G., van Haren, N. E. M., van Oel, C. J., Kahn, R. S., & Boomsma, D. I. (2002) · Brain · doi:10.1093/brain/awf035 · Cited by 50
The Neural Substrate of Orientation Working Memory
Cornette, L., Dupont, P. J., Salmon, É., & Orban, G. A. (2001) · Journal of Cognitive Neuroscience · doi:10.1162/08989290152541476 · Cited by 52
Predictive modeling in glioma grading from MR perfusion images using support vector machines
Emblem, K. E., Zöllner, F. G., Tennøe, B., Nedregaard, B., Nome, T., Due‐Tønnessen, P., Hald, J. K., Scheie, D., & Bjørnerud, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21736 · Cited by 50
Catafau, A. M., Pérez, V., Penengo, M. M., Bullich, S., Danùs, M., Puigdemont, D., Pascual, J. C., Corripio, I., Llop, J., Perich, J., et al. (2005) · PubMed · Cited by 50
Calmon, G., & Roberts, N. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00118-6 · Cited by 50
Retrospective Evaluation of Inter-subject Brain Registration
Pierre Hellier, J., Barillot, C., Corouge, I., Bernard Gibaud, A., Goualher, G. L., Collins, D. L., Evans, A. C., Malandain, G., & Ayache, N. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_31 · Cited by 50
Metadata
- Authors
- Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P.
- Affiliations
- KU Leuven (BE)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 187-198
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2034432063
- Cited by
- 4,547
- References
- 30
- Citations by year
- 2026: 80 · 2025: 84 · 2024: 93 · 2023: 85 · 2022: 116 · 2021: 130 · 2020: 121 · 2019: 124 · 2018: 171 · 2017: 153 · 2016: 139 · 2015: 183 · 2014: 195 · 2013: 212 · 2012: 209
- FWCI
- 71.00
- Type
- journal article
- Language
- en
- Open access
- green
- lirias.kuleuven.be
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- multimodal image registration, mutual information, rigid registration, Kullback-Leibler divergence, partial overlap, image degradation
- MeSH terms
- Algorithms, Brain, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review