The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Multimodality image registration by maximization of mutual information
Open accessAbstract
A new approach to the problem of multimodality medical image registration is proposed, using a basic concept from information theory, mutual information (MI), or relative entropy, as a new matching criterion. The method presented in this paper applies MI to measure the statistical dependence or information redundancy between the image intensities of corresponding voxels in both images, which is assumed to be maximal if the images are geometrically aligned. Maximization of MI is a very general and powerful criterion, because no assumptions are made regarding the nature of this dependence and no limiting constraints are imposed on the image content of the modalities involved. The accuracy of the MI criterion is validated for rigid body registration of computed tomography (CT), magnetic resonance (MR), and photon emission tomography (PET) images by comparison with the stereotactic registration solution, while robustness is evaluated with respect to implementation issues, such as interpolation and optimization, and image content, including partial overlap and image degradation. Our results demonstrate that subvoxel accuracy with respect to the stereotactic reference solution can be achieved completely automatically and without any prior segmentation, feature extraction, or other preprocessing steps which makes this method very well suited for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A 2D intraoperative X-ray can be registered to a 3D preoperative CT volume by maximizing its similarity to a rendered X-ray with respect to the camera pose [8, 14, 34].”
From Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering (2024) · cites this paper as [34]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions.”
From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While these metrics are positively correlated with pose differences when the perturbations in {K^v,T^xv,ω^D} are small, they are generally non-convex and fail to accurately represent pose offsets when perturbations are large.”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Conventional intensity-based methods mostly use hand-crafted similarity metrics between y v and its current best estimate y^v=(P(Kv,Txv)◦DωD)(x)fx1 as loss function. Common choices for the similarity metric are Normalized Cross Correlation (NCC), gradient information (Berger et al., 2016), or Mutual Information (MI) (Maes et al., 1997).”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 37,139
Pattern classification and scene analysis
Grenander, U., Duda, R., & Hart, P. (1974) · A Wiley-Interscience publication · doi:10.2307/1573081 · Cited by 17,399
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 12,040
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,079
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P. A., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,961
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & Cherry, A. S. R. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,636
Alignment by maximization of mutual information
Viola, P. A., & Wells, W. M. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.1995.466930 · Cited by 1,080
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 883
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Collignon, A. M. F., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534053 · Cited by 809
Self-citation
Flagged first, then by citations
Research works printed but not linked: 6
- fitzpatrick, 1994, Evaluation of retrospective image registration
- press, 1992, Numerical Recipes in C, 412
- collignon, 1995, automated multimodality medical image registration using information theory, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 263
- baddeley, 1992, an error metric for binary images, Proc IEEE Workshop on Robust Computer Vision, 59
- astola, 1982, entropy correlation coefficient, a measure of statistical dependence for categorized data, Proc Univ Vaasa Discussion Papers
- studholme, 1995, multiresolution voxel similarity measures for mr-pet registration, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 287
Cited by
Sorted by citations
Items 601–700 of 1,006
Stenkrona, P., Halldin, C., & Lundberg, J. (2013) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2013.01.002 · Cited by 78
Intensity-Based Image Registration by Nonparametric Local Smoothing
Chen, X., & Qiu, P. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2011.26 · Cited by 78
Choe, A. S., Stepniewska, I., Colvin, D. C., Ding, Z., & Anderson, A. W. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1810 · Cited by 78
Hartkens, T., Rueckert, D., Schnabel, J. A., Hawkes, D. J., & Hill, D. (2002) · Informatik aktuell · doi:10.1007/978-3-642-55983-9_96 · Cited by 78
Park, S., Yoon, J.-K., Kim, Y., Hwang, D., Cho, B., & Son, W. (2011) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2011.05.008 · Cited by 78
Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I
Pettersson, A., Kero, T., Gillot, L., Cannas, B., Fäldt, J., Söderberg, R. C., & Näsström, K. (2010) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(10)60072-8 · Cited by 78
Niu, T., Al-Basheer, A. K., & Zhu, L. (2012) · Medical Physics · doi:10.1118/1.3693050 · Cited by 78
Encoding Probabilistic Brain Atlases Using Bayesian Inference
Leemput, K. V. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2010434 · Cited by 80
Dual-core steered non-rigid registration for multi-modal images via bi-directional image synthesis
Cao, X., Yang, J., Gao, Y., Guo, Y., Guorong Wu, A., & Shen, D. G. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.05.004 · Cited by 78
Human Brain Regions Involved in Visual Categorization
Vogels, R., Sáry, G., Dupont, P. J., & Orban, G. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1109 · Cited by 78
A comparative study of warping and rigid body registration for the prostate and pelvic MR volumes
Fei, B., Kemper, C. A., & Wilson, D. L. (2003) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(02)00093-9 · Cited by 78
Detecting brain growth patterns in normal children using tensor‐based morphometry
Hua, X., Leow, A., Levitt, J. G., Caplan, R., Thompson, P. M., & Toga, A. W. (2007) · Human Brain Mapping · doi:10.1002/hbm.20498 · Cited by 77
Hecke, W. V., Sijbers, J., D’Agostino, E., Maes, F., Backer, S. D., Vandervliet, E., Parizel, P. M., & Leemans, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.006 · Cited by 77
Self-citationAccuracy of image registration between MRI and light microscopy in the ex vivo brain
Choe, A. S., Gao, Y., Li, X., Compton, K. B., Stepniewska, I., & Anderson, A. W. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.02.022 · Cited by 76
Lima, E. A. B. F., Oden, J. T., Wohlmuth, B. I., Shahmoradi, A., Hormuth, D. A., Yankeelov, T. E., Scarabosio, L., & Horger, T. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2017.08.009 · Cited by 77
FMRI Studies of the Supplementary Motor Area and the Premotor Cortex
Oostende, S. V., Hecke, P. V., Sunaert, S. G., Nuttin, B., & Marchal, G. (1997) · NeuroImage · doi:10.1006/nimg.1997.0287 · Cited by 77
Self-citationMeloni, S. M., Jovanovic, S. A., Urbán, I., Baldoni, E., Pisano, M., & Tallarico, M. (2019) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12808 · Cited by 76
Ardeshir Goshtasby, A. (2012) · Advances in computer vision and pattern recognition · doi:10.1007/978-1-4471-2458-0_11 · Cited by 76
Acute changes in regional cerebral (18)F-FDG kinetics in patients with traumatic brain injury.
Hattori, N., Huang, S., Wu, H.-M., Liao, W.-H., Glenn, T. C., Vespa, P. M., Phelps, M. E., Hovda, D. A., & Bergsneider, M. (2004) · PubMed · Cited by 76
Test-retest variability of quantitative [11C]PIB studies in Alzheimer’s disease
Tolboom, N., Yaqub, M. M., Boellaard, R., Luurtsema, G., Windhorst, A. D., Scheltens, P., Lammertsma, A. A., & van Berckel, B. N. M. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1129-6 · Cited by 76
Widespread and Prolonged Increase in (R)-11C-PK11195 Binding After Traumatic Brain Injury
Folkersma, H., Boellaard, R., Yaqub, M. M., Kloet, R. W., Windhorst, A. D., Lammertsma, A. A., Vandertop, W. P., & van Berckel, B. N. M. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.084061 · Cited by 76
Integration of sulcal and functional information for multimodal neuronavigation
Jannin, P., Morandi, X., Fleig, O. J., Rumeur, É. L., Toulouse, P., Bernard Gibaud, A., & Scarabin, J. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.96.4.0713 · Cited by 76
De Bellis, M. D., Hooper, S. R., Chen, S. D., Provenzale, J. M., Boyd, B. D., Glessner, C. E., MacFall, J. R., Payne, M. E., Rybczynski, R., & Woolley, D. P. (2015) · Development and Psychopathology · doi:10.1017/s0954579415000942 · Cited by 75
Fully Automatic Registration of Image Sets on Approximate Geometry
Corsini, M., Dellepiane, M., Ganovelli, F., Gherardi, R., Fusiello, A., & Scopigno, R. (2012) · International Journal of Computer Vision · doi:10.1007/s11263-012-0552-5 · Cited by 75
Structural and functional connectivity of the nondecussating dentato-rubro-thalamic tract
Petersen, K. J., Reid, J. A., Chakravorti, S., Juttukonda, M. R., Franco, G., Trujillo, P., Stark, A. J., Dawant, B. M., Donahue, M. J., & Claassen, D. O. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.04.074 · Cited by 75
Radiomics prognostication model in glioblastoma using diffusion- and perfusion-weighted MRI
Park, J. E., Kim, H. S., Jo, Y., Yoo, R., Choi, S. H., Nam, S. J., & Kim, J. H. (2020) · Scientific Reports · doi:10.1038/s41598-020-61178-w · Cited by 75
Cross-Modal Attention for MRI and Ultrasound Volume Registration
Song, X., Guo, H., Xu, X., Chao, H., Xu, S., Türkbey, B., Wood, B. J., Wang, G., & Yan, P. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87202-1_7 · Cited by 75
Real-time multi-modal rigid registration based on a novel symmetric-SIFT descriptor
Chen, J., & Tian, J. (2009) · Progress in Natural Science Materials International · doi:10.1016/j.pnsc.2008.06.029 · Cited by 75
Tracer kinetic model–driven registration for dynamic contrast‐enhanced MRI time‐series data
Buonaccorsi, G. A., O’Connor, J. P. B., Caunce, A., Roberts, C., Cheung, S., Watson, Y., Davies, K. E., Hope, L., Jackson, A., Jayson, G. C., et al. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21405 · Cited by 75
Babiloni, C., Pievani, M., Vecchio, F., Geroldi, C., Eusebi, F., Fracassi, C., Fletcher, E., De Carli, C., Boccardi, M., Rossini, P. M., et al. (2009) · Human Brain Mapping · doi:10.1002/hbm.20612 · Cited by 75
EVolution: an edge-based variational method for non-rigid multi-modal image registration
de Senneville, B. D., Zachiu, C., Ries, M. G., & MOONEN, C. T. W. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/20/7377 · Cited by 75
A data distributed parallel algorithm for nonrigid image registration
Ino, F., Ooyama, K., & Kenichi Hagihara, A. (2005) · Parallel Computing · doi:10.1016/j.parco.2004.12.001 · Cited by 75
Similarity and quality metrics for MR image-to-image translation
Dohmen, M., Klemens, M., Baltruschat, I. M., Truong, T., & Lenga, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-87358-0 · Cited by 74
Automated registration of dynamic MR images for the quantification of myocardial perfusion
Bidaut, L. M., & Vallée, J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1092 · Cited by 74
Slomka, P. J., Mandel, J., Downey, D. B., & Fenster, A. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00387-8 · Cited by 74
Heritability of DTI and MTR in nine-year-old children
Brouwer, R. M., Mandl, R. C. W., Peper, J. S., van Baal, G. C. M., Kahn, R. S., Boomsma, D. I., & Pol, H. E. H. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.017 · Cited by 74
Construction of lunar DEMs based on reflectance modelling
Grumpe, A., Belkhir, F., & Wöhler, C. (2013) · Advances in Space Research · doi:10.1016/j.asr.2013.09.036 · Cited by 74
Accurate real-time tracking using mutual information
Dame, A., & Marchand, É. (2010) · Proceedings - International Symposium on Mixed and Augmented Reality, ISMAR · doi:10.1109/ismar.2010.5643550 · Cited by 74
Loubele, M., Jacobs, R., Maes, F., Schutyser, F., Debaveye, D., Bogaerts, R., Coudyzer, W., Vandermeulen, D., Cleynenbreugel, J. V., Marchal, G., et al. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nci749 · Cited by 74
Self-citationAutomated generation of a four‐dimensional model of the liver using warping and mutual information
Brock, K., Balter, J. M., Dawson, L. A., Kessler, M. L., & Meyer, C. R. (2003) · Medical Physics · doi:10.1118/1.1576781 · Cited by 74
Model-Based and Data-Driven Strategies in Medical Image Computing
Rueckert, D., & Schnabel, J. A. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2943836 · Cited by 76
Current Concepts of Analysis of Cerebral White Matter Hyperintensities on Magnetic Resonance Imaging
Yoshita, M., Fletcher, E. M., & DeCarli, C. S. (2005) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000245456.98029.a8 · Cited by 76
Seibert, T. M., White, N. S., Kim, G.-Y., Moiseenko, V., McDonald, C. R., Farid, N., Bartsch, H., Kuperman, J. M., Karunamuni, R. A., Marshall, D. C., et al. (2016) · Practical Radiation Oncology · doi:10.1016/j.prro.2016.05.008 · Cited by 73
Emblem, K. E., Nedregaard, B., Hald, J. K., Nome, T., Due‐Tønnessen, P., & Bjørnerud, A. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21815 · Cited by 73
Lindseth, F., Kaspersen, J. H., Ommedal, S., Langø, T., Bang, J., Hokland, J., Unsgaard, G., & Hernes, T. A. N. (2003) · Computer Aided Surgery · doi:10.3109/10929080309146040 · Cited by 73
Dupont, P. J., Paesschen, W. V., Palmini, A., Ambayi, R., Loon, J. V., Goffin, J., Weckhuysen, S., Sunaert, S. G., Thomas, B., Demaerel, P., et al. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00628.x · Cited by 72
Tract-based diffusion tensor imaging in patients with schizophrenia and their non-psychotic siblings
Boos, H. B. M., Mandl, R. C. W., van Haren, N. E. M., Cahn, W., van Baal, G. C. M., Kahn, R. S., & Pol, H. E. H. (2012) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2012.05.015 · Cited by 72
Hart, H. C., Hall, D. A., & Palmer, A. R. (2003) · Hearing Research · doi:10.1016/s0378-5955(03)00100-x · Cited by 73
Brain growth rate abnormalities visualized in adolescents with autism
Hua, X., Thompson, P. M., Leow, A., Madsen, S. K., Caplan, R., Alger, J. R., O’Neill, J., Joshi, K., Smalley, S. L., Toga, A. W., et al. (2011) · Human Brain Mapping · doi:10.1002/hbm.21441 · Cited by 74
Woodward, N. D., Zald, D. H., Ding, Z., Riccardi, P., Ansari, M. S., Baldwin, R. M., Cowan, R. L., Li, R., & KESSLER, R. M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.049 · Cited by 72
iElectrodes: A Comprehensive Open-Source Toolbox for Depth and Subdural Grid Electrode Localization
Blenkmann, A. O., Phillips, H. N., Princich, J. P., Rowe, J. B., Bekinschtein, T. A., Muravchik, C. H., & Kochen, S. S. (2017) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2017.00014 · Cited by 77
Leemans, A., Sijbers, J., Backer, S. D., Vandervliet, E. J. M., & Parizel, P. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20898 · Cited by 71
Menten, M. J., Mohajer, J., Nilawar, R., Bertholet, J., Dunlop, A., Pathmanathan, A. U., Moreau, M., Marshall, S., Wetscherek, A., Nill, S., et al. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.12.010 · Cited by 71
Koenis, M. M. G., Brouwer, R. M., van den Heuvel, M. P., Mandl, R. C. W., van Soelen, I. L. C., Kahn, R. S., Boomsma, D. I., & Pol, H. E. H. (2015) · Human Brain Mapping · doi:10.1002/hbm.22988 · Cited by 78
Velde, G. V., Rangarajan, J. R., Toelen, J., Dresselaers, T., Ibrahimi, A., Krylychkina, O., Vreys, R., der Linden, A. V., Maes, F., Debyser, Z., et al. (2011) · Gene Therapy · doi:10.1038/gt.2011.2 · Cited by 76
Self-citationAmygdala Volume in Late-Life Depression: Relationship with Age of Onset
Burke, J., McQuoid, D. R., Payne, M. E., Steffens, D. C., Krishnan, R. R., & Taylor, W. D. (2011) · American Journal of Geriatric Psychiatry · doi:10.1097/jgp.0b013e318211069a · Cited by 71
Sanuki, N., Takeda, A., Oku, Y., Eriguchi, T., Nishimura, S., Aoki, Y., Mizuno, T., Iwabuchi, S., & Kunieda, E. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2013.10.045 · Cited by 71
Shams, R., Sadeghi, P., Kennedy, R. A., & Hartley, R. I. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.11.004 · Cited by 71
Camp, N. V., Blockx, I., Verhoye, M., Casteels, C., Coun, F., Leemans, A., Sijbers, J., Baekelandt, V., Laere, K. V., & der Linden, A. V. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1381 · Cited by 71
Zheng, W., Kim, J. P., Kadbi, M., Movsas, B., Chetty, I. J., & Glide‐Hurst, C. K. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.07.001 · Cited by 71
Labeling of ambiguous subvoxel fibre bundle configurations in high angular resolution diffusion MRI
Savadjiev, P., Campbell, J. S. W., Descoteaux, M., Rachid Deriche, B., Pike, G. B., & Kaleem Siddiqi, A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.028 · Cited by 71
Automatic Registration of Mass Spectrometry Imaging Data Sets to the Allen Brain Atlas
Abdelmoula, W. M., Carreira, R. J., Shyti, R., Balluff, B., van Zeijl, R. J. M., Tolner, E. A., Lelieveldt, B. P. F., van den Maagdenberg, A. M. J. M., McDonnell, L. A., & Dijkstra, J. (2014) · Analytical Chemistry · doi:10.1021/ac500148a · Cited by 71
Rueckert, D., & Schnabel, J. A. (2010) · Biological and medical physics series · doi:10.1007/978-3-642-15816-2_5 · Cited by 75
3D spatial compounding of ultrasound images using image-based nonrigid registration
Krücker, J. F., Meyer, C. R., LeCarpentier, G. L., Fowlkes, J. B., & Carson, P. L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00286-6 · Cited by 71
Computing Accurate Correspondences across Groups of Images
Cootes, T. F., Twining, C. J., Petrovic, V. S., Babalola, K. O., & Taylor, C. J. (2010) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2009.193 · Cited by 70
Bi-Modality Medical Image Synthesis Using Semi-Supervised Sequential Generative Adversarial Networks
Yang, X. Y., Lin, Y., Wang, Z., Li, X. S., & Cheng, K.-T. T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2922986 · Cited by 70
STREM: A Robust Multidimensional Parametric Method to Segment MS Lesions in MRI
Aït-Ali, L., Prima, S., Pierre Hellier, J., Carsin-Nicol, B., Edan, G., & Barillot, C. (2005) · Lecture notes in computer science · doi:10.1007/11566465_51 · Cited by 70
Probabilistic Brain Tissue Segmentation in Neonatal Magnetic Resonance Imaging
Anbeek, P., Vincken, K. L., Groenendaal, F., Koeman, A., van Osch, M. J. P., & van der Grond, J. (2008) · Pediatric Research · doi:10.1203/pdr.0b013e31815ed071 · Cited by 70
Legg, P., Rosin, P. L., Marshall, D., & Morgan, J. E. (2013) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2013.08.004 · Cited by 70
Survey of Non-Rigid Registration Tools in Medicine
Keszei, A. P., Berkels, B., & Deserno, T. M. (2016) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-016-9915-8 · Cited by 70
Lee, M. K., Park, J. E., Jo, Y., Park, S. Y., Kim, S. J., & Kim, H. S. (2019) · European Radiology · doi:10.1007/s00330-019-06395-2 · Cited by 71
Hata, N., Nabavi, A., Wells, W. M., Warfield, S. K., Kikinis, R., Black, P. M., & Jolesz, F. A. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200007000-00004 · Cited by 70
Salient Feature Region: A New Method for Retinal Image Registration
Zheng, J., Tian, J., Deng, K., Dai, X., Zhang, X., & Xu, M. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2091145 · Cited by 69
Automatic Localization of Cochlear Implant Electrodes in CT
Zhao, Y., Dawant, B. M., Labadie, R. F., & Noble, J. H. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-10404-1_42 · Cited by 69
Slagter, K. W., Raghoebar, G. M., Hentenaar, D. F. M., Vissink, A., & Meijer, H. J. A. (2020) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13398 · Cited by 69
Self-Distillation Feature Learning Network for Optical and SAR Image Registration
Quan, D., Wei, H., Wang, S., Lei, R., Duan, B., Li, Y., Hou, B., & Jiao, L. (2022) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2022.3173476 · Cited by 69
Learning Based Non-rigid Multi-modal Image Registration Using Kullback-Leibler Divergence
Guetter, C., Xu, C., Sauer, F., & Joachim Hornegger, A. (2005) · Lecture notes in computer science · doi:10.1007/11566489_32 · Cited by 69
Multimodal Data Fusion Based on Mutual Information
Bramon, R., Boada, I., Bardera, A., Rodriguez, J., Feixas, M., Puig, J., & Sbert, M. (2011) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2011.280 · Cited by 69
Virtual occlusion in planning orthognathic surgical procedures
Nadjmi, N., Mollemans, W., Daelemans, A., Hemelen, G. V., Schutyser, F., & Bergé, S. J. (2010) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2010.02.002 · Cited by 69
Segmentation of Vectorial Image Features Using Shape Gradients and Information Measures
Herbulot, A., Jehan‐Besson, S., Duffner, S., Barlaud, M., & Aubert, G. (2006) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-006-6898-y · Cited by 69
Li, X., Dawant, B. M., Welch, E. B., Chakravarthy, A. B., Freehardt, D., Mayer, I. A., Kelley, M. C., Meszoely, I. M., Gore, J. C., & Yankeelov, T. E. (2009) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.05.007 · Cited by 69
Three-dimensional strain fields in human brain resulting from formalin fixation
Schulz, G. V., Crooijmans, H. J. A., Germann, M., Scheffler, K., Müller‐Gerbl, M., & Müller, B. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.08.031 · Cited by 69
Park, Y. W., Han, K., Ahn, S. S., Choi, Y. S., Chang, J. H., Kim, S. H., Kang, S., Kim, E. H., & Lee, S. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5569 · Cited by 69
Phantom validation of coregistration of PET and CT for image‐guided radiotherapy
Lavely, W. C., Scarfone, C., Çevıkalp, H., Li, R., Byrne, D. W., Cmelak, A. J., Dawant, B. M., Price, R. R., Hallahan, D. E., & Fitzpatrick, J. M. (2004) · Medical Physics · doi:10.1118/1.1688041 · Cited by 69
Watkins, T. J. (2011) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2011.156 · Cited by 69
Robust Feature Matching for Remote Sensing Image Registration via Linear Adaptive Filtering
Jiang, X., Ma, J., Fan, A., Xu, H., Lin, G., Lü, T., & Tian, X. S. (2020) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2020.3001089 · Cited by 68
Saha, P. K. (2005) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2005.03.003 · Cited by 68
Kim, S., Quon, H., Loevner, L. A., Rosen, M. A., Dougherty, L., Kilger, A., Glickson, J. D., & Poptani, H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21207 · Cited by 68
Nonrigid Registration of Medical Images: Theory, Methods, and Applications [Applications Corner
Rueckert, D., & Aljabar, P. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936850 · Cited by 68
Computer-based system for the virtual-endoscopic guidance of bronchoscopy
Helferty, J. P., Sherbondy, A. J., Kiraly, A. P., & Higgins, W. E. (2007) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.10.010 · Cited by 68
Chakravarty, M. M., Sadikot, A. F., Germann, J., Pierre Hellier, J., Bertrand, G., & Collins, D. L. (2009) · Human Brain Mapping · doi:10.1002/hbm.20780 · Cited by 70
Cooper, L., Sertel, O., Kong, J., Lozanski, G., Huang, K., & Gürcan, M. N. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.04.012 · Cited by 68
Vitikainen, A.-M., Lioumis, P., Paetau, R., Salli, E., Komssi, S., Metsähonkala, L., Paetau, A. E., Kičić, D., Blomstedt, G. C., Valanne, L. K., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.026 · Cited by 68
Koenis, M. M. G., Brouwer, R. M., Swagerman, S. C., van Soelen, I. L. C., Boomsma, D. I., & Pol, H. E. H. (2017) · Human Brain Mapping · doi:10.1002/hbm.23885 · Cited by 72
Boyd, S. K., Moser, S., Kuhn, M. H., Klinck, R. J., Krauze, P. L., Müller, R., & Gasser, J. A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9168-7 · Cited by 68
Statistical analysis of normal and abnormal dissymmetry in volumetric medical images
Thirion, J.-P., Prima, S., Subsol, G., & Roberts, N. P. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00012-8 · Cited by 68
Torsten Rohlfing, B., Maurer, C. R., O’Dell, W. G., & Zhong, J. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.428073 · Cited by 68
A survey on mutual information based medical image registration algorithms
Sengupta, D., Gupta, P., & Biswas, A. (2021) · Neurocomputing · doi:10.1016/j.neucom.2021.11.023 · Cited by 67
Huntjens, E., Kiss, G., Wouters, C. H., & Carels, C. E. L. (2008) · European Journal of Orthodontics · doi:10.1093/ejo/cjn056 · Cited by 67
Homocysteine effects on brain volumes mapped in 732 elderly individuals
Rajagopalan, P., Hua, X., Toga, A. W., Jack, C. R., Weiner, M. W., & Thompson, P. M. (2011) · Neuroreport · doi:10.1097/wnr.0b013e328346bf85 · Cited by 67
Metadata
- Authors
- Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P.
- Affiliations
- KU Leuven (BE)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 187-198
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2034432063
- Cited by
- 4,547
- References
- 30
- Citations by year
- 2026: 80 · 2025: 84 · 2024: 93 · 2023: 85 · 2022: 116 · 2021: 130 · 2020: 121 · 2019: 124 · 2018: 171 · 2017: 153 · 2016: 139 · 2015: 183 · 2014: 195 · 2013: 212 · 2012: 209
- FWCI
- 71.00
- Type
- journal article
- Language
- en
- Open access
- green
- lirias.kuleuven.be
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- multimodal image registration, mutual information, rigid registration, Kullback-Leibler divergence, partial overlap, image degradation
- MeSH terms
- Algorithms, Brain, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review