A new approach to the problem of multimodality medical image registration is proposed, using a basic concept from information theory, mutual information (MI), or relative entropy, as a new matching criterion. The method presented in this paper applies MI to measure the statistical dependence or information redundancy between the image intensities of corresponding voxels in both images, which is assumed to be maximal if the images are geometrically aligned. Maximization of MI is a very general and powerful criterion, because no assumptions are made regarding the nature of this dependence and no limiting constraints are imposed on the image content of the modalities involved. The accuracy of the MI criterion is validated for rigid body registration of computed tomography (CT), magnetic resonance (MR), and photon emission tomography (PET) images by comparison with the stereotactic registration solution, while robustness is evaluated with respect to implementation issues, such as interpolation and optimization, and image content, including partial overlap and image degradation. Our results demonstrate that subvoxel accuracy with respect to the stereotactic reference solution can be achieved completely automatically and without any prior segmentation, feature extraction, or other preprocessing steps which makes this method very well suited for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A 2D intraoperative X-ray can be registered to a 3D preoperative CT volume by maximizing its similarity to a rendered X-ray with respect to the camera pose [8, 14, 34].”
From Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering (2024) · cites this paper as [34]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions.”
From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While these metrics are positively correlated with pose differences when the perturbations in {K^v,T^xv,ω^D} are small, they are generally non-convex and fail to accurately represent pose offsets when perturbations are large.”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Conventional intensity-based methods mostly use hand-crafted similarity metrics between y v and its current best estimate y^v=(P(Kv,Txv)◦DωD)(x)fx1 as loss function. Common choices for the similarity metric are Normalized Cross Correlation (NCC), gradient information (Berger et al., 2016), or Mutual Information (MI) (Maes et al., 1997).”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 37,139
Pattern classification and scene analysis
Grenander, U., Duda, R., & Hart, P. (1974) · A Wiley-Interscience publication · doi:10.2307/1573081 · Cited by 17,399
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 12,040
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,079
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P. A., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,961
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & Cherry, A. S. R. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,636
Alignment by maximization of mutual information
Viola, P. A., & Wells, W. M. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.1995.466930 · Cited by 1,080
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 883
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Collignon, A. M. F., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534053 · Cited by 809
Self-citation
Flagged first, then by citations
Research works printed but not linked: 6
- fitzpatrick, 1994, Evaluation of retrospective image registration
- press, 1992, Numerical Recipes in C, 412
- collignon, 1995, automated multimodality medical image registration using information theory, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 263
- baddeley, 1992, an error metric for binary images, Proc IEEE Workshop on Robust Computer Vision, 59
- astola, 1982, entropy correlation coefficient, a measure of statistical dependence for categorized data, Proc Univ Vaasa Discussion Papers
- studholme, 1995, multiresolution voxel similarity measures for mr-pet registration, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 287
Cited by
Sorted by citations
Items 401–500 of 1,006
Reading Fluent Speech from Talking Faces: Typical Brain Networks and Individual Differences
Hall, D. A., Fussell, C., & Summerfield, A. Q. (2005) · Journal of Cognitive Neuroscience · doi:10.1162/0898929054021175 · Cited by 118
Reduction of dorsolateral prefrontal cortex gray matter in late-life depression
Chang, C., Yu, S.-C., McQuoid, D. R., Messer, D. F., Taylor, W. D., Singh, K., Boyd, B. D., Krishnan, K. R., MacFall, J. R., Steffens, D. C., et al. (2011) · Psychiatry Research Neuroimaging · doi:10.1016/j.pscychresns.2011.01.003 · Cited by 119
Orthogonal acoustic dimensions define auditory field maps in human cortex
Barton, B., Venezia, J. H., Saberi, K., Hickok, G. S., & Brewer, A. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1213381109 · Cited by 112
Clements, L. W., Chapman, W. C., Dawant, B. M., Galloway, R. L., & Miga, M. I. (2008) · Medical Physics · doi:10.1118/1.2911920 · Cited by 112
Castadot, P., Geets, X., Lee, J. A., Christian, N., & Grégoire, V. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.03.007 · Cited by 112
Four challenges in medical image analysis from an industrial perspective
Weese, J., & Lorenz, C. D. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.023 · Cited by 112
Handschuh, S., Baeumler, N., Schwaha, T., & Ruthensteiner, B. (2013) · Frontiers in Zoology · doi:10.1186/1742-9994-10-44 · Cited by 113
Complexity-Entropy Causality Plane as a Complexity Measure for Two-Dimensional Patterns
Ribeiro, H. V., Zunino, L., Lenzi, E. K., Santoro, P. A., & Mendes, R. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0040689 · Cited by 111
Machine Learning for Auto-Segmentation in Radiotherapy Planning
Harrison, K., Pullen, H., Welsh, C., Oktay, O., Alvarez-Valle, J., & Jena, R. (2022) · Clinical Oncology · doi:10.1016/j.clon.2021.12.003 · Cited by 123
Vandenbergh, J., Dupont, P. J., Fischler, B., Bormans, G. M., Persoons, P., Janssens, J., & Tack, J. F. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.054 · Cited by 111
Cattaneo, P. M., Treccani, M., Carlsson, K., Thorgeirsson, T., Myrda, A., Cevidanes, L., & Melsen, B. (2011) · Orthodontics and Craniofacial Research · doi:10.1111/j.1601-6343.2011.01527.x · Cited by 111
Combined MEG and EEG source imaging by minimization of mutual information
Baillet, S., Garnero, L., Marin, G., & Hugonin, J. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759053 · Cited by 111
Casteels, C., Vermaelen, P., Nuyts, J. L., der Linden, A. V., Baekelandt, V., Mortelmans, L. A., Bormans, G. M., & Laere, K. V. (2006) · PubMed · Cited by 111
Winter, S., Brendel, B., Pechlivanis, I., Schmieder, K., & Igel, C. (2008) · IEEE Transactions on Evolutionary Computation · doi:10.1109/tevc.2007.907558 · Cited by 110
Digital tomosynthesis with an on-board kilovoltage imaging device
Godfrey, D., Yin, F.-F., Oldham, M., Yoo, S., & Willett, C. G. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.025 · Cited by 110
Quantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT.
Soret, M., Koulibaly, P. M., Darcourt, J., Hapdey, S., & Buvat, I. (2003) · PubMed · Cited by 110
Dessel, J. V., Huang, Y., Depypere, M., Rubira‐Bullen, I. R. F., Maes, F., & Jacobs, R. (2013) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20130145 · Cited by 110
Self-citationLundqvist, R., Lilja, J., Thomas, B. A., Lötjönen, J. M. P., Villemagne, V. L., Rowe, C. C., & Thurfjell, L. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.115006 · Cited by 110
Bhushan, C., Haldar, J. P., Choi, S., Joshi, A. A., Shattuck, D. W., & Leahy, R. M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.050 · Cited by 109
Registration of [18F]FDG microPET and small-animal MRI
Rowland, D. J., Garbow, J. R., Laforest, R. A., & Snyder, A. Z. (2005) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2005.05.002 · Cited by 109
Multispectral Filter-Wheel Cameras: Geometric Distortion Model and Compensation Algorithms
Brauers, J., Schulte, N., & Aach, T. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.2006605 · Cited by 109
Zaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.031 · Cited by 108
Body-part-specific Representations of Semantic Noun Categories
Carota, F., Moseley, R. L., & Friedemann Pulvermüller, A. (2012) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00219 · Cited by 116
Park, S., Yang, Y., Kim, Y., Cho, B., Jung, Y., & Hwang, D. (2011) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2011.08.017 · Cited by 108
Brouwer, R. M., Mandl, R. C. W., Schnack, H. G., van Soelen, I. L. C., van Baal, G. C., Peper, J. S., Kahn, R. S., Boomsma, D. I., & Pol, H. E. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032316 · Cited by 107
Self-similarity weighted mutual information: A new nonrigid image registration metric
Rivaz, H. J., Karimaghaloo, Z., & Collins, D. L. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.12.003 · Cited by 107
Local feature matching using deep learning: A survey
Xu, S., Chen, S., Xu, R., Wang, C., Lu, P., & Guo, L. (2024) · Information Fusion · doi:10.1016/j.inffus.2024.102344 · Cited by 107
Torrens, M. J., Chung, C. D., Chung, H., Hanssens, P. E. J., Jaffray, D. A., Kemeny, A. A., Larson, D. A., Levivier, M., Lindquist, C., Lippitz, B. E., et al. (2014) · Journal of neurosurgery · doi:10.3171/2014.7.gks141199 · Cited by 106
Corsini, M., Dellepiane, M., Ponchio, F., & Scopigno, R. (2009) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2009.01552.x · Cited by 106
Hemelen, G. V., Genechten, M. V., Renier, L., Desmedt, M., Verbruggen, E., & Nadjmi, N. (2015) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2015.04.006 · Cited by 106
Hecke, W. V., Leemans, A., D’Agostino, E., Backer, S. D., Vandervliet, E. J. M., Parizel, P. M., & Sijbers, J. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.906786 · Cited by 106
Chen, Z., Li, J., Sinjab, K. H., Mendonça, G., Yu, H., & Wang, H. (2018) · Clinical Oral Implants Research · doi:10.1111/clr.13382 · Cited by 105
Image Fusion Using Adjustable Non-subsampled Shearlet Transform
Vishwakarma, A., & Bhuyan, M. K. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2877285 · Cited by 105
Rubins, D. J. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.011 · Cited by 105
Cerebral white matter in early puberty is associated with luteinizing hormone concentrations
Peper, J. S., Brouwer, R. M., Schnack, H. G., van Baal, G. C. M., van Leeuwen, M., van den Berg, S. M., de Waal, H. A. D., Janke, A. L., Collins, D. L., Evans, A. C., et al. (2008) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.03.017 · Cited by 108
Wong, D. F., Waterhouse, R. N., Kuwabara, H., Kim, J., Brašić, J. R., Chamroonrat, W., Stabins, M., Holt, D. P., Dannals, R. F., Hamill, T. G., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107995 · Cited by 105
Vasconcelos, K. D. F., Nicolielo, L. F. P., Nascimento, M. D. C. C., Neto, F. H., Bóscolo, F. N., Dessel, J. V., EzEldeen, M., Lambrichts, I., & Jacobs, R. (2014) · International Endodontic Journal · doi:10.1111/iej.12395 · Cited by 104
Diffusion tensor imaging, permanent pyramidal tract damage, and outcome in subcortical stroke
Radlinska, B. A., Ghinani, S. A., Leppert, I. R., Minuk, J., Pike, G. B., & Thiel, A. (2010) · Neurology · doi:10.1212/wnl.0b013e3181f39aa0 · Cited by 104
ROUSSET, O. G., Collins, D. L., Rahmim, A., & Wong, D. F. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.048330 · Cited by 104
Multimodality image registration with software: state-of-the-art
Slomka, P. J., & Baum, R. P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0941-8 · Cited by 103
Hsu, J., Hecke, W. V., Bai, C., Lee, C.-H., Tsai, Y., Chiu, H., Jaw, F.-S., Hsu, C., Leu, J.-G., Chen, W.-H., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.031 · Cited by 106
Oostendorp, M., Douma, K., Hackeng, T. M., Dirksen, A., Post, M. J., van Zandvoort, M. A. M. J., & Backes, W. H. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-0689 · Cited by 107
Information Theory in Scientific Visualization
Wang, C., & Shen, H. (2011) · Entropy · doi:10.3390/e13010254 · Cited by 103
Automatic registration of optical imagery with 3D LiDAR data using statistical similarity
Parmehr, E. G., Fraser, C. S., Chunsun Zhang, A., & Leach, J. (2013) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2013.11.015 · Cited by 103
Hauk, O., Davis, M. H., Kherif, F., & Friedemann Pulvermüller, A. (2008) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2008.06143.x · Cited by 105
Unberath, M., Gao, C., Hu, Y., Judish, M., Taylor, R. H., Armand, M., & Grupp, R. (2021) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.716007 · Cited by 102
“Common choices for the similarity metric are Normalized Cross Correlation (NCC), gradient information [23], or Mutual Information (MI) [27].”
BackgroundZhuang, X., Arridge, S., Hawkes, D. J., & Sebastien Ourselin, A. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2150240 · Cited by 102
Friedemann Pulvermüller, A., Kherif, F., Hauk, O., Mohr, B., & Nimmo‐Smith, I. (2009) · Human Brain Mapping · doi:10.1002/hbm.20811 · Cited by 105
Fei, B., Duerk, J. L., Boll, D. T., Lewin, J. S., & Wilson, D. L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809078 · Cited by 102
Quantitative Evaluation of Image-Based Distortion Correction in Diffusion Tensor Imaging
Netsch, T., & vanMuiswinkel, A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.827479 · Cited by 102
Soto, D. E., Kessler, M. L., Piert, M., & Eisbruch, A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.05.021 · Cited by 101
Vos, P., Hambrock, T., Barenstz, J. O., & Huisman, H. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/6/012 · Cited by 101
Torsten Rohlfing, B., & Maurer, C. R. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.884936 · Cited by 108
Implementation and application of a brain template for multiple volumes of interest
Hammers, A., Koepp, M. J., Free, S. L., Brett, M., Richardson, M. P., Labbé, C., Cunningham, V. J., Brooks, D. J., & Duncan, J. S. (2002) · Human Brain Mapping · doi:10.1002/hbm.10016 · Cited by 101
A Comparison of Neural Circuits Underlying Auditory and Visual Object Categorization
Adams, R. B., & Janata, P. (2002) · NeuroImage · doi:10.1006/nimg.2002.1088 · Cited by 101
Schwarz, C. G., Fletcher, E., DeCarli, C. S., & Carmichael, O. T. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02498-6_20 · Cited by 100
The University of North Carolina at Chapel Hill University Libraries (2020) · PubMed · doi:10.17615/nbx8-cb81 · Cited by 100
Automated Separation of Gray and White Matter from MR Images of the Human Brain
Schnack, H. G., Pol, H. E. H., Baaré, W. F. C., Staal, W., Viergever, M. A., & Kahn, R. S. (2001) · NeuroImage · doi:10.1006/nimg.2000.0669 · Cited by 101
Distribution of Dopamine D2-Like Receptors in the Human Thalamus: Autoradiographic and PET Studies
Rieck, R. W., Ansari, M. S., Whetsell, W. O., Deutch, A. Y., & KESSLER, R. M. (2003) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300336 · Cited by 103
Groupwise Diffeomorphic Non-rigid Registration for Automatic Model Building
Cootes, T. F., Marsland, S., Twining, C., Smith, K., & Taylor, C. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-24673-2_26 · Cited by 100
Region Mutual Information Loss for Semantic SegmentationPreprint
Zhao, S., Wang, Y., Yang, Z., & Cai, D. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.12037 · Cited by 100
Auhustinack, J. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00042 · Cited by 102
A Penalized Likelihood Approach to Image Warping
Glasbey, C. A., & Mardia, K. V. (2001) · Journal of the Royal Statistical Society Series B (Statistical Methodology) · doi:10.1111/1467-9868.00295 · Cited by 99
Survey on liver CT image segmentation methods
Mharib, A. M., Ramli, A. R., Mashohor, S., & Mahmood, R. (2011) · Artificial Intelligence Review · doi:10.1007/s10462-011-9220-3 · Cited by 99
Laperre, K., Depypere, M., van Gastel, N., Torrekens, S., Moermans, K., Bogaerts, R., Maes, F., & Carmeliet, G. (2011) · Bone · doi:10.1016/j.bone.2011.06.031 · Cited by 99
Self-citationMAP MRF joint segmentation and registration of medical images
Wyatt, P. P., & Noble, J. A. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00067-7 · Cited by 99
Towards a Better Comprehension of Similarity Measures Used in Medical Image Registration
Roche, A., Malandain, G., Ayache, N., & Prima, S. (1999) · Lecture notes in computer science · doi:10.1007/10704282_60 · Cited by 99
Evaluation of automatic neonatal brain segmentation algorithms: The NeoBrainS12 challenge
Išgum, I., Benders, M. J. N. L., Avants, B., Cardoso, M. J., Counsell, S. J., Fischi-Gómez, E., Gui, L., Hüppi, P. S., Kersbergen, K. J., Makropoulos, A., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.11.001 · Cited by 98
Radiomics for Response and Outcome Assessment for Non-Small Cell Lung Cancer
Shi, L., He, Y., Yuan, Z., Benedict, S., Valicenti, R. K., Qiu, J., & Rong, Y. (2018) · Technology in Cancer Research & Treatment · doi:10.1177/1533033818782788 · Cited by 98
Deng, S., Franklin, C. G., O’Boyle, M. W., Zhang, W., Heyl, B. L., Jerabek, P. A., Lu, H., & Fox, P. T. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118923 · Cited by 99
Validation of x-ray microfocus computed tomography as an imaging tool for porous structures
Kerckhofs, G., Schrooten, J., Cleynenbreugel, T. V., Lomov, S. V., & Wevers, M. (2008) · Review of Scientific Instruments · doi:10.1063/1.2838584 · Cited by 98
Cardiac Three-Dimensional Magnetic Resonance Imaging and Fluoroscopy Merging
Ector, J., Buck, S. D., Adams, J., Dymarkowski, S., Bogaert, J. G., Maes, F., & Heidbüchel, H. (2005) · Circulation · doi:10.1161/circulationaha.105.565002 · Cited by 99
Self-citationMulti-sensor image registration based on intensity and edge orientation information
Kim, Y. S., Lee, J., & Ra, J. B. (2008) · Pattern Recognition · doi:10.1016/j.patcog.2008.04.017 · Cited by 98
Riccardi, P., Zald, D., Li, R., Park, S., Ansari, M., Dawant, B., Anderson, S. A., Woodward, N., Schmidt, D., Baldwin, R., et al. (2006) · American Journal of Psychiatry · doi:10.1176/ajp.2006.163.9.1639 · Cited by 104
Liu, Y., Teverovskiy, L., Carmichael, O. T., Kikinis, R., Shenton, M. E., Carter, C. S., Stenger, V. A., Davis, S. W., Aizenstein, H. J., Becker, J. T., et al. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30135-6_48 · Cited by 98
Lin, Y., Yau, H., Wang, I., Zheng, C., & Chung, K. (2013) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12119 · Cited by 97
Improving the Learning of Multi-column Convolutional Neural Network for Crowd Counting
Cheng, Z.-Q., Li, J.-X., Dai, Q., Wu, X. Y., He, J.-Y., & Hauptmann, A. G. (2019) · ACM International Conference on Multimedia (ACM MM) · doi:10.1145/3343031.3350898 · Cited by 97
Mouras, H., Stoléru, S., Moulier, V., Pélégrini‐Issac, M., Rouxel, R., Grandjean, B., Glutron, D., & Bittoun, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.051 · Cited by 101
Shiradkar, R., Podder, T. K., Algohary, A., Viswanath, S. E., Ellis, R. J., & Madabhushi, A. (2016) · Radiation Oncology · doi:10.1186/s13014-016-0718-3 · Cited by 96
PET/CT scanner instrumentation, challenges, and solutions
Alessio, A. M., Kinahan, P. E., Cheng, P. M., Vesselle, H. J., & Karp, J. S. (2004) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2004.08.001 · Cited by 96
Volume image registration by template matching
Ding, L., Ardeshir Goshtasby, A., & Satter, M. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00101-3 · Cited by 96
Klumpers, U. M. H., Veltman, D. J., Drent, M. L., Boellaard, R., Comans, E. F. I., Meynen, G., Lammertsma, A. A., & Hoogendijk, W. J. G. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1292-9 · Cited by 95
Vanderstuyft, T., Tarce, M., Sanaan, B., Jacobs, R., Vasconcelos, K. D. F., & Quirynen, M. (2019) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13183 · Cited by 95
Kumarasiri, A., Siddiqui, F., Liu, C., Yechieli, R. L., Shah, M., Pradhan, D. R., Zhong, H., Chetty, I. J., & Kim, J. (2014) · Medical Physics · doi:10.1118/1.4901409 · Cited by 95
Differential Evolution as a viable tool for satellite image registration
Falco, I. D., Cioppa, A. D., Maisto, D., & Tarantino, E. (2007) · Applied Soft Computing · doi:10.1016/j.asoc.2007.10.013 · Cited by 95
Liang, J., Liu, X., Huang, K., Li, X., Wang, D., & Wang, X. (2013) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2013.2242895 · Cited by 95
Shekhar, R., Walimbe, V., Raja, S., Zagrodsky, V., Kanvinde, M., Wu, G., & Bybel, B. (2005) · PubMed · Cited by 95
Evaluation of Reference Tissue Models for the Analysis of [ 11 C]( R )-PK11195 Studies
Kropholler, M. A., Boellaard, R., Schuitemaker, A., Folkersma, H., van Berckel, B. N. M., & Lammertsma, A. A. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600289 · Cited by 94
Pirotte, B. J. M., Goldman, S., Bogaert, P. V., David, P., Wikler, D., Rorive, S., Brotchi, J., & Levivier, M. (2005) · Operative Neurosurgery · doi:10.1227/01.neu.0000163598.59870.6d · Cited by 94
A Mosaicing Scheme for Pose-Invariant Face Recognition
Singh, R., Mayank Vatsa, A., Ross, A. A., & Afzel Noore, B. (2007) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2007.903537 · Cited by 94
Lee, K., Kim, Y., Park, S., & Son, W. (2012) · The Angle Orthodontist · doi:10.2319/081711-526.1 · Cited by 94
In vivo imaging of cartilage degeneration using μCT-arthrography
Piscaer, T. M., Waarsing, J. H., Kops, N., Pavljasevic, P., Verhaar, J. A. N., van Osch, G. J. V. M., & Weinans, H. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.01.012 · Cited by 94
General multimodal elastic registration based on mutual information
Maintz, J. B. A., Meijering, E. H. W., & Viergever, M. A. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.310845 · Cited by 94
Carota, F., Kriegeskorte, N., Nili, H., & Friedemann Pulvermüller, A. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhw379 · Cited by 101
Multifunctional Carbon-Based Nanomaterials: Applications in Biomolecular Imaging and Therapy
Zhang, Y., Wu, M., Wu, M., Zhu, J., & Zhang, X. (2018) · ACS Omega · doi:10.1021/acsomega.8b01071 · Cited by 95
Molecular imaging of cell death
Saint‐Hubert, M. D., Prinsen, K., Mortelmans, L. A., Verbruggen, A., & Mottaghy, F. M. (2009) · Methods · doi:10.1016/j.ymeth.2009.03.022 · Cited by 97
Roberson, P. L., McLaughlin, P. W., Narayana, V., Troyer, S., Hixson, G. V., & Kessler, M. L. (2005) · Medical Physics · doi:10.1118/1.1851920 · Cited by 93
A protocol for evaluation of similarity measures for rigid registration
Škerl, D., Likar, B., & Pernuš, F. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.874963 · Cited by 93
Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.
Slomka, P. J., Dey, D., Przetak, C., Aladl, U. E., & Baum, R. P. (2003) · PubMed · Cited by 93
Comparing isotropic and anisotropic smoothing for voxel‐based DTI analyses: A simulation study
Hecke, W. V., Leemans, A., Backer, S. D., Jeurissen, B., Parizel, P. M., & Sijbers, J. (2009) · Human Brain Mapping · doi:10.1002/hbm.20848 · Cited by 92
Metadata
- Authors
- Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P.
- Affiliations
- KU Leuven (BE)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 187-198
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2034432063
- Cited by
- 4,547
- References
- 30
- Citations by year
- 2026: 80 · 2025: 84 · 2024: 93 · 2023: 85 · 2022: 116 · 2021: 130 · 2020: 121 · 2019: 124 · 2018: 171 · 2017: 153 · 2016: 139 · 2015: 183 · 2014: 195 · 2013: 212 · 2012: 209
- FWCI
- 71.00
- Type
- journal article
- Language
- en
- Open access
- green
- lirias.kuleuven.be
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- multimodal image registration, mutual information, rigid registration, Kullback-Leibler divergence, partial overlap, image degradation
- MeSH terms
- Algorithms, Brain, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review