A new approach to the problem of multimodality medical image registration is proposed, using a basic concept from information theory, mutual information (MI), or relative entropy, as a new matching criterion. The method presented in this paper applies MI to measure the statistical dependence or information redundancy between the image intensities of corresponding voxels in both images, which is assumed to be maximal if the images are geometrically aligned. Maximization of MI is a very general and powerful criterion, because no assumptions are made regarding the nature of this dependence and no limiting constraints are imposed on the image content of the modalities involved. The accuracy of the MI criterion is validated for rigid body registration of computed tomography (CT), magnetic resonance (MR), and photon emission tomography (PET) images by comparison with the stereotactic registration solution, while robustness is evaluated with respect to implementation issues, such as interpolation and optimization, and image content, including partial overlap and image degradation. Our results demonstrate that subvoxel accuracy with respect to the stereotactic reference solution can be achieved completely automatically and without any prior segmentation, feature extraction, or other preprocessing steps which makes this method very well suited for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A 2D intraoperative X-ray can be registered to a 3D preoperative CT volume by maximizing its similarity to a rendered X-ray with respect to the camera pose [8, 14, 34].”
From Intraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering (2024) · cites this paper as [34]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Conventional intensity-based 2D/3D registration approaches suffer from a limited capture range due to the presence of local minima in hand-crafted image similarity functions.”
From A Fully Differentiable Framework for 2D/3D Registration and the Projective Spatial Transformers (2024) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While these metrics are positively correlated with pose differences when the perturbations in {K^v,T^xv,ω^D} are small, they are generally non-convex and fail to accurately represent pose offsets when perturbations are large.”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Conventional intensity-based methods mostly use hand-crafted similarity metrics between y v and its current best estimate y^v=(P(Kv,Txv)◦DωD)(x)fx1 as loss function. Common choices for the similarity metric are Normalized Cross Correlation (NCC), gradient information (Berger et al., 2016), or Mutual Information (MI) (Maes et al., 1997).”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Maes et al., 1997
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 37,139
Pattern classification and scene analysis
Grenander, U., Duda, R., & Hart, P. (1974) · A Wiley-Interscience publication · doi:10.2307/1573081 · Cited by 17,399
(1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 12,895
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 12,040
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,079
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P. A., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,961
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & Cherry, A. S. R. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,636
Alignment by maximization of mutual information
Viola, P. A., & Wells, W. M. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.1995.466930 · Cited by 1,080
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., KESSLER, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 883
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Collignon, A. M. F., Vandermeulen, D., Marchal, G., & Suetens, P. (1996) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.1996.534053 · Cited by 809
Self-citation
Flagged first, then by citations
Research works printed but not linked: 6
- fitzpatrick, 1994, Evaluation of retrospective image registration
- press, 1992, Numerical Recipes in C, 412
- collignon, 1995, automated multimodality medical image registration using information theory, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 263
- baddeley, 1992, an error metric for binary images, Proc IEEE Workshop on Robust Computer Vision, 59
- astola, 1982, entropy correlation coefficient, a measure of statistical dependence for categorized data, Proc Univ Vaasa Discussion Papers
- studholme, 1995, multiresolution voxel similarity measures for mr-pet registration, Proc 14th Int Conf Information Processing in Medical Imaging Computational Imaging and Vision 3, 287
Cited by
Sorted by citations
Items 301–400 of 1,006
Frouin, V., Comtat, C., Reilhac, A., & Grégoire, M. (2002) · PubMed · Cited by 148
Prendes, J., Chabert, M., Pascal, F., Giros, A., & Tourneret, J. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2387013 · Cited by 147
BrainAligner: 3D registration atlases of Drosophila brains
Peng, H., Chung, P., Long, F., Qu, L., Jenett, A., Seeds, A. M., Myers, E. W., & Simpson, J. H. (2011) · Nature Methods · doi:10.1038/nmeth.1602 · Cited by 147
Segmentation of multiple sclerosis lesions in MR images: a review
Mortazavi, D., Kouzani, A. Z., & Hamid Soltanian-zadeh, A. (2011) · Neuroradiology · doi:10.1007/s00234-011-0886-7 · Cited by 146
Automated measurement of brain and white matter lesion volume in type 2 diabetes mellitus
Jongen, C., van der Grond, J., Kappelle, L. J., Biessels, G. J., Viergever, M. A., Pluim, J. P. W., & on behalf of the Utrecht Diabetic Encephalopathy Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0688-y · Cited by 146
Intensity-based 2-D-3-D registration of cerebral angiograms
Hipwell, J. H., Penney, G., McLaughlin, R. A., Rhode, K., Summers, P. E., Cox, T. C. S., Byrne, J. V., Noble, J. A., & Hawkes, D. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819283 · Cited by 146
Visualization in Medicine: Theory, Algorithms, and Applications
Preim, B., & Bartz, D. (2007) · Cited by 145
Neuronuclear Assessment of Patients With Epilepsy
Goffin, K. E., Dedeurwaerdere, S., Laere, K. V., & Paesschen, W. V. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.02.004 · Cited by 145
Simulation of brain tumors in MR images for evaluation of segmentation efficacy
Prastawa, M. W., Bullitt, E., & Gerig, G. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.11.002 · Cited by 151
Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coils
Boyes, R. G., Gunter, J. L., Frost, C. D., Janke, A. L., Yeatman, T., Hill, D., Bernstein, M. A., Thompson, P. M., Weiner, M. W., Schuff, N. W., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.10.026 · Cited by 144
Interactions between different EEG frequency bands and their effect on alpha - fMRI correlations
de Munck, J. C., Goncalves, S. I., Mammoliti, R., Heethaar, R. M., & Lopes, F. H. D. S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.029 · Cited by 150
Category-specific Conceptual Processing of Color and Form in Left Fronto-temporal Cortex
Friedemann Pulvermüller, A., & Hauk, O. (2005) · Cerebral Cortex · doi:10.1093/cercor/bhj060 · Cited by 150
Wang, Z., Liu, C., Cheng, D., Wang, L., Yang, X. Y., & Cheng, K.-T. T. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2789181 · Cited by 143
Chen, Y., He, F., Li, H., Zhang, D., & Wu, Y. (2020) · Applied Soft Computing · doi:10.1016/j.asoc.2020.106335 · Cited by 143
Tourassi, G. D., Vargas‐Voracek, R., Catarious, D. M., & Floyd, C. E. (2003) · Medical Physics · doi:10.1118/1.1589494 · Cited by 143
Russakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Microglial activation in healthy aging
Schuitemaker, A., van der Doef, T. F., Boellaard, R., van der Flier, W. M., Yaqub, M., Windhorst, A. D., Barkhof, F., Jonker, C., Kloet, R. W., Lammertsma, A. A., et al. (2012) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2010.09.016 · Cited by 142
Is Synthesizing MRI Contrast Useful for Inter-modality Analysis?
Iglesias, J. E., Konukoğlu, E., Zikic, D., Glocker, B., Leemput, K. V., & Fischl, B. R. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_79 · Cited by 142
Mutual information matching in multiresolution contexts
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00054-8 · Cited by 142
Robust midsagittal plane extraction from normal and pathological 3-D neuroradiology images
Liu, Y., Collins, R. T., & Rothfus, W. E. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.918469 · Cited by 142
Intracranial Vessel Wall Imaging at 7.0-T MRI
van der Kolk, A. G., Zwanenburg, J. J. M., Brundel, M., Biessels, G. J., Visser, F., Luijten, P. R., & Hendrikse, J. (2011) · Stroke · doi:10.1161/strokeaha.111.620443 · Cited by 141
Schulz, G. V., Weitkamp, T., Zanette, I., Pfeiffer, F., Beckmann, F., Dávid, C., Rutishauser, S., Reznikova, E. F., & Müller, B. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0281 · Cited by 141
Learning deep similarity metric for 3D MR–TRUS image registration
Haskins, G., Kruecker, J., Kruger, U., Xu, S., Pinto, P. A., Wood, B. J., & Yan, P. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-018-1875-7 · Cited by 140
Mohammadi, S., Möller, H. E., Kugel, H., Müller, D. K., & Deppe, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22501 · Cited by 140
Pirotte, B. J. M., Goldman, S., Dewitte, O., Massager, N., Wikler, D., Lefranc, F., Taib, N. O. B., Rorive, S., David, P., Brotchi, J., et al. (2006) · Journal of neurosurgery · doi:10.3171/jns.2006.104.2.238 · Cited by 140
Nonrigid registration of 3D tensor medical data
Ruiz‐Alzola, J., Westin, C., Warfield, S. K., Alberola‐López, C., Maier, S. E., & Kikinis, R. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00055-5 · Cited by 140
Otake, Y., Armand, M., Armiger, R. S., Kutzer, M. D. M., Basafa, E., Kazanzides, P., & Taylor, R. H. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2176555 · Cited by 140
Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain
Fitzpatrick, J. M., Hill, D., Shyr, Y., West, J. B., Studholme, C., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730402 · Cited by 140
Non-rigid registration of multi-modal images using both mutual information and cross-correlation
Andronache, A., VONSIEBENTHAL, M., Székely, G. J., & Cattin, P. C. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.06.005 · Cited by 139
Image qualityvsradiation dose of four cone beam computed tomography scanners
Loubele, M., Jacobs, R., Maes, F., Denis, K., White, S. C., Coudyzer, W., Lambrichts, I., van Steenberghe, D., & Suetens, P. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/16770531 · Cited by 138
Self-citationNeuroanatomical correlates of penile erection evoked by photographic stimuli in human males
Moulier, V., Mouras, H., Pélégrini‐Issac, M., Glutron, D., Rouxel, R., Grandjean, B., Bittoun, J., & Stoléru, S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.06.037 · Cited by 141
Consistent Linear-Elastic Transformations for Image Matching
Christensen, G. E. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_17 · Cited by 138
Gait Feature Subset Selection by Mutual Information
Guo, B., & Nixon, M. S. (2008) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2008.2007977 · Cited by 139
Pouratian, N., Bookheimer, S. Y., Rex, D., Martin, N. A., & Toga, A. W. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.97.1.0021 · Cited by 137
Image registration: an essential tool for nuclear medicine
Hutton, B. F., Braun, M., Thurfjell, L., & Lau, D. Y. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0700-6 · Cited by 136
Kessler, R. M., Woodward, N. D., Riccardi, P., Li, R., Ansari, M. S., Anderson, S., Dawant, B., Zald, D., & Meltzer, H. Y. (2009) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.12.029 · Cited by 136
Fluorescent imaging of cancerous tissues for targeted surgery
Bu, L., Shen, B., & Cheng, Z. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.008 · Cited by 141
Sarrut, D., Boldea, V., Miguet, S., & Ginestet, C. (2006) · Medical Physics · doi:10.1118/1.2161409 · Cited by 135
A New 3D Tool for Assessing the Accuracy of Bimaxillary Surgery: The OrthoGnathicAnalyser
Baan, F., Liebregts, J., Xi, T., Schreurs, R., de Koning, M. J. J., Bergé, S. J., & Maal, T. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149625 · Cited by 134
Efficient Population Registration of 3D Data
Zöllei, L., Miller, E. G., Grimson, W. E. L., & Wells, W. M. (2005) · Lecture notes in computer science · doi:10.1007/11569541_30 · Cited by 134
Coselmon, M. M., Balter, J. M., McShan, D. L., & Kessler, M. L. (2004) · Medical Physics · doi:10.1118/1.1803671 · Cited by 134
Cross-modal attention for multi-modal image registration
Song, X., Chao, H., Xu, X., Guo, H., Xu, S., Türkbey, B., Wood, B. J., Sanford, T., Wang, G., & Yan, P. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102612 · Cited by 133
Bokkers, R. P. H., Bremmer, J. P., van Berckel, B. N. M., Lammertsma, A. A., Hendrikse, J., Pluim, J. P. W., Kappelle, L. J., Boellaard, R., & Klijn, C. J. M. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.204 · Cited by 132
Connectivity trajectory across lifespan differentiates the precuneus from the default network
Yang, Z., Chang, C., Xu, T., Jiang, L., Handwerker, D. A., Castellanos, F. X., Milham, M. P., Bandettini, P. A., & Zuo, X. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.039 · Cited by 133
Fang, W., Huang, S., Huang, Q., Huang, G., Wang, H. E., Leng, G., & Wang, L. (2020) · Journal of Hydrology · doi:10.1016/j.jhydrol.2020.125287 · Cited by 131
$f$ -Information Measures in Medical Image Registration
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.836872 · Cited by 130
Mutual Information-Based Visual Servoing
Dame, A., & Marchand, É. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2147090 · Cited by 130
Kang, D., Park, J. E., Kim, Y., Kim, J. H., Oh, J. Y., Kim, J., Kim, Y. K., Kim, S. T., & Kim, H. S. (2018) · Neuro-Oncology · doi:10.1093/neuonc/noy021 · Cited by 129
Level set based cerebral vasculature segmentation and diameter quantification in CT angiography
Manniesing, R., Velthuis, B. K., van Leeuwen, M. S., van der Schaaf, I. C., van Laar, P. J., & Niessen, W. J. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.09.001 · Cited by 128
Semiautomatic 3-D image registration as applied to interventional MRI liver cancer treatment
Carrillo, A., Duerk, J. L., Lewin, J. S., & Wilson, D. L. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845176 · Cited by 128
No-reference color image quality assessment: from entropy to perceptual quality
Chen, X., Zhang, Q., Lin, M., Yang, G., & He, C. (2019) · EURASIP Journal on Image and Video Processing · doi:10.1186/s13640-019-0479-7 · Cited by 127
Labadie, R. F., Balachandran, R., Noble, J. H., Blachon, G. S., Mitchell, J. E., Reda, F. A., Dawant, B. M., & Fitzpatrick, J. M. (2013) · The Laryngoscope · doi:10.1002/lary.24520 · Cited by 126
Yoon, K., Lee, W., Lee, J. E., Xu, L., Croce, P., Foley, L., & Yoo, S.-S. (2019) · PLoS ONE · doi:10.1371/journal.pone.0224311 · Cited by 114
Multi-modal volume registration using joint intensity distributions
Leventon, M. E., & Grimson, W. E. L. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056295 · Cited by 125
Tip Fold-over in Cochlear Implantation: Case Series
Zuniga, M. G., Rivas, A., Hedley-Williams, A. J., Gifford, R. H., Dwyer, R. T., Dawant, B. M., Sunderhaus, L. W., Yancey, K. L., Wanna, G. B., Noble, J. H., et al. (2016) · Otology & Neurotology · doi:10.1097/mao.0000000000001283 · Cited by 124
Wolthaus, J., van Herk, M., Muller, S. H., Belderbos, J. S. A., Lebesque, J. V., de Bois, J. A., Rossi, M. M. G., & Damen, E. M. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/7/017 · Cited by 124
Magnetic Resonance–Guided Adaptive Radiotherapy: A Solution to the Future
Kupelian, P. A., & Sonke, J. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.013 · Cited by 123
Robust point matching method for multimodal retinal image registration
Wang, G., Wang, Z., Chen, Y., & Zhao, W. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.03.004 · Cited by 123
Deformable Image Registration Using a Cue-Aware Deep Regression Network
Cao, X., Yang, J., Zhang, J., Wang, Q., Yap, P., & Shen, D. G. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2822826 · Cited by 123
Cranial base superimposition for 3-dimensional evaluation of soft-tissue changes
Cevidanes, L., Motta, A. T., Proffit, W. R., Ackerman, J. L., & Styner, M. A. (2010) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.04.021 · Cited by 123
Comparison and Evaluation of Rigid, Affine, and Nonrigid Registration of Breast MR Images
Denton, E., Sonoda, L. I., Rueckert, D., Rankin, S., Hayes, C., Leach, M. O., Hill, D., & Hawkes, D. J. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199909000-00031 · Cited by 123
Betke, M., Hong, H., Thomas, D., Prince, C. N., & Ko, J. P. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00007-0 · Cited by 123
Non-rigid multimodal image registration using mutual information
Gaens, T., Maes, F., Vandermeulen, D., & Suetens, P. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056299 · Cited by 123
Self-citationSun, Y., Lübbers, H., Agbaje, J. O., Schepers, S., Vrielinck, L. J. G., Lambrichts, I., & Politis, C. (2013) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e31829a80d9 · Cited by 122
Occupancy of Striatal and Extrastriatal Dopamine D2 Receptors by Clozapine and Quetiapine
Kessler, R. M., Ansari, M., Riccardi, P., Li, R., Jayathilake, K., Dawant, B., & Meltzer, H. Y. (2006) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301108 · Cited by 123
Inverse-Consistent Deep Networks for Unsupervised Deformable Image RegistrationPreprint
Zhang, J. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.03443 · Cited by 122
Angelini, E. D., Clatz, O., Mandonnet, E., Konukoğlu, E., Capelle, L., & Duffau, H. (2007) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/157340507782446241 · Cited by 125
Image Registration by Maximization of Combined Mutual Information and Gradient Information
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_46 · Cited by 121
Simultaneous misalignment correction for approximate circular cone-beam computed tomography
Kyriakou, Y., Lapp, R. M., Hillebrand, L., Ertel, D., & Kalender, W. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/22/001 · Cited by 120
Similarity and Dissimilarity Measures
Ardeshir Goshtasby, A. (2012) · Advances in computer vision and pattern recognition · doi:10.1007/978-1-4471-2458-0_2 · Cited by 126
Automatic segmentation of different-sized white matter lesions by voxel probability estimation
Anbeek, P., Vincken, K. L., van Osch, M. J. P., Bisschops, R., & van der Grond, J. (2004) · Medical Image Analysis · doi:10.1016/j.media.2004.06.019 · Cited by 119
Integration of 3D and multispectral data for cultural heritage applications: Survey and perspectives
Simon-Chane, C., Mansouri, A., Marzani, F. S., & Boochs, F. (2012) · Image and Vision Computing · doi:10.1016/j.imavis.2012.10.006 · Cited by 119
Anatomical-Based FDG-PET Reconstruction for the Detection of Hypo-Metabolic Regions in Epilepsy
Baete, K., Nuyts, J. L., Paesschen, W. V., Suetens, P., & Dupont, P. J. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825623 · Cited by 119
Self-citationVMAT2 and dopamine neuron loss in a primate model of Parkinson’s disease
Chen, M., Kuwabara, H., Zhou, Y., Adams, R. J., Brašić, J. R., McGlothan, J. L., Verina, T., Burton, N. C., Alexander, M., Kumar, A., et al. (2007) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2007.05108.x · Cited by 119
Jin, X., Mulnix, T., Gallezot, J., & Carson, R. E. (2013) · Medical Physics · doi:10.1118/1.4819820 · Cited by 119
Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET
Baete, K., Nuyts, J. L., Laere, K. V., Paesschen, W. V., Ceyssens, S. K., Ceuninck, L. D., Gheysens, O. S., Kelles, A., den Eynden, J. V., Suetens, P., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.041 · Cited by 118
Self-citationRobust Multispectral Image Registration Using Mutual-Information Models
Kern, J. P., & Pattichis, M. S. (2007) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2007.892599 · Cited by 118
Rigid point feature registration using mutual information
Rangarajan, A., Chui, H., & Duncan, J. S. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80034-6 · Cited by 118
Automatic Segmentation of the Ventricular System from MR Images of the Human Brain
Schnack, H. G., Pol, H. E. H., Baaré, W. F. C., Viergever, M. A., & Kahn, R. S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0800 · Cited by 118
Cha, J., Kim, S. T., Kim, H.-J., Kim, B., Kim, Y. K., Lee, J. Y., Jeon, P., Kim, K. H., Kong, D., & Nam, D. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3876 · Cited by 117
Software for image registration: Algorithms, accuracy, efficacy
Hutton, B. F., & Braun, M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127309 · Cited by 117
Deformation tensor morphometry of semantic dementia with quantitative validation
Studholme, C., Cardenas, V. A., Blumenfeld, R., Schuff, N. W., Rosen, H. J., Miller, B. L., & Weiner, M. W. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.009 · Cited by 116
Software approach to merging molecular with anatomic information.
Slomka, P. J. (2004) · PubMed · Cited by 116
Quantitative assessment of small bowel motility by nonrigid registration of dynamic MR images
Odille, F., Menys, A., Ahmed, A., Punwani, S., Taylor, S. A., & Atkinson, D. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23298 · Cited by 115
Brewer, A., & Barton, B. (2012) · Frontiers in Psychology · doi:10.3389/fpsyg.2014.00074 · Cited by 116
A machine learning approach for feature selection traffic classification using security analysis
Shafiq, M., Yu, X., Bashir, A. K., Chaudhry, H. N., & Wang, D. (2018) · The Journal of Supercomputing · doi:10.1007/s11227-018-2263-3 · Cited by 115
Regional Cerebral Blood Flow During Gastric Balloon Distention in Functional Dyspepsia
Vandenberghe, J. U., Dupont, P. J., Oudenhove, L. V., Bormans, G. M., Demyttenaere, K., Fischler, B., Geeraerts, B., Janssens, J., & Tack, J. F. (2007) · Gastroenterology · doi:10.1053/j.gastro.2007.03.037 · Cited by 115
Barrick, T. R., Mackay, C. E., Prima, S., Maes, F., Vandermeulen, D., Crow, T. J., & Roberts, N. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.003 · Cited by 117
Self-citationPappatà, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1121 · Cited by 115
Automatic Brain and Tumor Segmentation
Moon, N., Bullitt, E., Leemput, K. V., & Gerig, G. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_46 · Cited by 115
Tourassi, G. D., Harrawood, B. P., Singh, S., Lo, J. Y.-C., & Floyd, C. E. (2006) · Medical Physics · doi:10.1118/1.2401667 · Cited by 115
Ogasawara, K., Ito, H., Sasoh, M., Okuguchi, T., Kobayashi, M., Yukawa, H., Terasaki, K., & Ogawa, A. (2003) · PubMed · Cited by 115
Image interpolation in 4D CT using a BSpline deformable registration model
Schreibmann, E., Chen, G. T. Y., & Xing, L. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.11.018 · Cited by 114
Linac-integrated kV-cone beam CT: Technical features and first applications
Oelfke, U., Tücking, T., Nill, S., Seeber, A., Hesse, B. M., Huber, P., & Thilmann, C. (2006) · Medical dosimetry · doi:10.1016/j.meddos.2005.12.008 · Cited by 114
Accuracy assessment of computer‐assisted flapless implant placement in partial edentulism
Assche, N. V., van Steenberghe, D., Quirynen, M., & Jacobs, R. (2010) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2010.01535.x · Cited by 114
Morphology-driven automatic segmentation of MR images of the neonatal brain
Gui, L., Lisowski, R., Faundez, T., Hüppi, P. S., Lazeyras, F., & Kocher, M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.07.006 · Cited by 117
Simultaneous multi-modality ROI delineation in clinical practice
Bol, G. H., Kotte, A. N. T. J., van der Heide, U. A., & Lagendijk, J. J. W. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.04.008 · Cited by 114
Dilated FCN for Multi-Agent 2D/3D Medical Image Registration
Miao, S., Piat, S., Fischer, P., Tuysuzoglu, A., Mewes, P., Mansi, T., & Liao, R. (2018) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v32i1.11576 · Cited by 113
Yun, J., Park, J. E., Lee, H., Ham, S., Kim, N., & Kim, H. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-42276-w · Cited by 113
Mathematical methods in medical image processing
Angenent, S., Pichon, É., & Tannenbaum, A. (2006) · Bulletin of the American Mathematical Society · doi:10.1090/s0273-0979-06-01104-9 · Cited by 113
Metadata
- Authors
- Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P.
- Affiliations
- KU Leuven (BE)
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997-04
- Volume
- 16
- Issue
- 2
- Pages
- 187-198
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2034432063
- Cited by
- 4,547
- References
- 30
- Citations by year
- 2026: 80 · 2025: 84 · 2024: 93 · 2023: 85 · 2022: 116 · 2021: 130 · 2020: 121 · 2019: 124 · 2018: 171 · 2017: 153 · 2016: 139 · 2015: 183 · 2014: 195 · 2013: 212 · 2012: 209
- FWCI
- 71.00
- Type
- journal article
- Language
- en
- Open access
- green
- lirias.kuleuven.be
- Locations
- IEEE Transactions on Medical Imaging (publishedVersion)
- PubMed (publishedVersion)
- Lirias (submittedVersion, other-oa)
- Funders
- Fonds De La Recherche Scientifique - FNRS
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Keywords
- multimodal image registration, mutual information, rigid registration, Kullback-Leibler divergence, partial overlap, image degradation
- MeSH terms
- Algorithms, Brain, Diagnostic Imaging, Humans, Image Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review