The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Registration of head volume images using implantable fiducial markers
Abstract
In this paper, we describe an extrinsic-point-based, interactive image-guided neurosurgical system designed at Vanderbilt University, Nashville, TN, as part of a collaborative effort among the Departments of Neurological Surgery, Computer Science, and Biomedical Engineering. Multimodal image-to-image (II) and image-to-physical (IP) registration is accomplished using implantable markers. Physical space tracking is accomplished with optical triangulation. We investigate the theoretical accuracy of point-based registration using numerical simulations, the experimental accuracy of our system using data obtained with a phantom, and the clinical accuracy of our system using data acquired in a prospective clinical trial by six neurosurgeons at four medical centers from 158 patients undergoing craniotomies to resect cerebral lesions. We can determine the position of our markers with an error of approximately 0.4 mm in X-ray computed tomography (CT) and magnetic resonance (MR) images and 0.3 mm in physical space. The theoretical registration error using four such markers distributed around the head in a configuration that is clinically practical is approximately 0.5-0.6 mm. The mean CT-physical registration error for the phantom experiments is 0.5 mm and for the clinical data obtained with rigid head fixation during scanning is 0.7 mm. The mean CT-MR registration error for the clinical data obtained without rigid head fixation during scanning is 1.4 mm, which is the highest mean error that we observed. These theoretical and experimental findings indicate that this system is an accurate navigational aid that can provide real-time feedback to the surgeon about anatomical structures encountered in the surgical field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
A Generalized Solution of the Orthogonal Procrustes Problem
Schönemann, P. H. (1966) · Psychometrika · doi:10.1007/bf02289451 · Cited by 2,040
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Facial Growth in Man, Studied with the AID of Metallic Implants
Björk, A. (1955) · Acta Odontologica Scandinavica · doi:10.3109/00016355509028170 · Cited by 571
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
Self-citationThe procrustes program: Producing direct rotation to test a hypothesized factor structure
Hurley, J. R., & Cattell, R. B. (2007) · Behavioral Science · doi:10.1002/bs.3830070216 · Cited by 347
An image-directed robotic system for precise orthopaedic surgery
Taylor, R. H., Mittelstadt, B. D., Paul, H. A., Hanson, W., Kazanzides, P., Zuhars, J. F., Williamson, B., Musits, B. L., Glassman, E., & Bargar, W. L. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.294202 · Cited by 347
Grimson, W. E. L., Ettinger, G. J., White, S. J., Lozano-Perez, T., Wells, W. M., & Kikinis, R. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491415 · Cited by 316
Cited by
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Predicting error in rigid-body point-based registration
Fitzpatrick, J. M., West, J. B., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736021 · Cited by 1,010
Self-citationA Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
The distribution of target registration error in rigid-body point-based registration
Fitzpatrick, J. M., & West, J. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952729 · Cited by 457
Self-citationMedical image registration using mutual information
Maes, F., Vandermeulen, D., & Suetens, P. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.817864 · Cited by 432
Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00066 · Cited by 404
Self-citationBrain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
Advanced Medical Displays: A Literature Review of Augmented Reality
Sielhorst, T., Feuerstein, M., & Navab, N. (2008) · Journal of Display Technology · doi:10.1109/jdt.2008.2001575 · Cited by 308
A study of the motion and deformation of the heart due to respiration
McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804427 · Cited by 281
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Computer assisted oral and maxillofacial surgery – a review and an assessment of technology
Hassfeld, S., & Mühling, J. (2001) · International Journal of Oral and Maxillofacial Surgery · doi:10.1054/ijom.2000.0024 · Cited by 263
Interpolation Artefacts in Mutual Information-Based Image Registration
Pluim, J. P. W., Antoine Maintz, J. B., & Viergever, M. A. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.1999.0816 · Cited by 255
Bayesian Characterization of Uncertainty in Intra-subject Non-rigid Registration
Risholm, P., Janoos, F., Norton, I., Golby, A. J., & Wells, W. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.002 · Cited by 62
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Virtual reality based hybrid simulation for functional endoscopic sinus surgery
Jain, S., Lee, S., Barber, S. R., Chang, E. H., & Son, Y.-J. (2020) · IISE Transactions on Healthcare Systems Engineering · doi:10.1080/24725579.2019.1692263 · Cited by 20
X-Ray to CT Rigid Registration Using Scene Coordinate Regression
Shrestha, P., Xie, C., Shishido, H., Yoshii, Y., & Kitahara, I. (2023) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-43999-5_74 · Cited by 12
Metadata
- Authors
- Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997
- Volume
- 16
- Issue
- 4
- Pages
- 447-462
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2162977111
- Cited by
- 561
- References
- 25
- FWCI
- 23.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.