The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)
Abstract
An overview of the Shinnar-Le Roux (SLR) algorithm is presented. It is shown how the performance of SLR pulses can be very accurately specified analytically. This reveals how to design a pulse that produces a specified slice profile and allows the pulse designer to trade off analytically the parameters describing the pulse performance. Several examples are presented to illustrate the more important tradeoffs. These include linear-phase and minimum- and maximum-phase pulses. Linear-phase pulses can be refocused with a gradient reversal and can be used as spin-echo pulses. Minimum- and maximum-phase pulses have better slice profiles, but cannot be completely refocused.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory and Application of Digital Signal Processing
Rabiner, L. R., Gold, B., & Yuen, C. K. (1978) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1978.4309918 · Cited by 2,797
Theory and application of digital signal processing
Trick, T. N. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10027 · Cited by 1,878
Yarlagadda, R. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162867 · Cited by 1,739
Parks, T. W., & Burrus, C. S. (1987) · Cited by 793
Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem
Conolly, S., Nishimura, D., & Macovski, A. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307754 · Cited by 278
Self-citationAn introduction to NMR imaging: From the Bloch equation to the imaging equation
Hinshaw, W. S., & Lent, A. H. (1983) · Proceedings of the IEEE · doi:10.1109/proc.1983.12592 · Cited by 213
The synthesis of pulse sequences yielding arbitrary magnetization vectors
Shinnar, M., Eleff, S. M., Subramanian, H., et al. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910120109 · Cited by 119
Cited by
NMR techniques for quantum control and computation
Vandersypen, L. M. K., & Chuang, I. L. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.76.1037 · Cited by 1,217
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
The role of skeletal muscle insulin resistance in the pathogenesis of the metabolic syndrome
Petersen, K. F., Dufour, S., Savage, D. B., Bilz, S., Solomon, G., Yonemitsu, S., Cline, G. W., Befroy, D., Zemany, L., Kahn, B. B., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705408104 · Cited by 759
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S. C. L., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 744
The neural substrates of affective processing in depressed patients treated with venlafaxine
Davidson, R. J., Irwin, W., Anderle, M. J., & Kalin, N. H. (2003) · American Journal of Psychiatry · doi:10.1176/appi.ajp.160.1.64 · Cited by 487
Deoni, S. C. L., Peters, T. M., & Rutt, B. K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 478
Gleaning multicomponent T1 and T2 information from steady‐state imaging data
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21704 · Cited by 472
Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts
Kreis, R. (2004) · NMR in Biomedicine · doi:10.1002/nbm.891 · Cited by 430
Extended phase graphs: Dephasing, RF pulses, and echoes ‐ pure and simple
Weigel, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24619 · Cited by 426
Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles
Cunningham, C. H., Arai, T., Yang, P. C., McConnell, M. V., Pauly, J. M., & Conolly, S. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20477 · Cited by 403
Self-citationDeuterium metabolic imaging (DMI) for MRI-based 3D mapping of metabolism in vivo
De Feyter, H. M., Behar, K. L., Corbin, Z. A., Fulbright, R. K., Brown, P. B., McIntyre, S., Nixon, T. W., Rothman, D. L., & de Graaf, R. A. (2018) · Science Advances · doi:10.1126/sciadv.aat7314 · Cited by 376
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Single-scan multidimensional magnetic resonance
Tal, A., & Frydman, L. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.04.001 · Cited by 277
A multispectral three‐dimensional acquisition technique for imaging near metal implants
Koch, K. M., Lorbiecki, J. E., Hinks, R. S., & King, K. F. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21856 · Cited by 269
Methodology of Resonant Equiangular Composite Quantum Gates
Low, G. H., Yoder, T. J., & Chuang, I. L. (2016) · Physical Review X · doi:10.1103/physrevx.6.041067 · Cited by 159
“One noteworthy step in this direction is the Shinnar–Le Roux algorithm [31,32] and its refinements [33–35], which have so far been restricted to the field of magnetic resonance imaging.”
MethodTechnical Note: Deep learning based MRAC using rapid ultrashort echo time imaging
Jang, H., Liu, F., Zhao, G., Bradshaw, T., & McMillan, A. B. (2018) · Medical Physics · doi:10.1002/mp.12964 · Cited by 60
Subrahmanian, M. V., Pavuluri, K., Olivieri, C., & Veglia, G. (2022) · PNAS Nexus · doi:10.1093/pnasnexus/pgac133 · Cited by 24
Metadata
- Authors
- Pauly, J., Le Roux, P., Nishimura, D., & Macovski, A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1991-03
- Volume
- 10
- Issue
- 1
- Pages
- 53-65
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2161044358
- Cited by
- 800
- References
- 7
- FWCI
- 11.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.