We have evaluated eight different similarity measures used for rigid body registration of serial magnetic resonance (MR) brain scans. To assess their accuracy we used 33 clinical three-dimensional (3-D) serial MR images, with deformable extradural tissue excluded by manual segmentation and simulated 3-D MR images with added intensity distortion. For each measure we determined the consistency of registration transformations for both sets of segmented and unsegmented data. We have shown that of the eight measures tested, the ones based on joint entropy produced the best consistency. In particular, these measures seemed to be least sensitive to the presence of extradural tissue. For these data the difference in accuracy of these joint entropy measures, with or without brain segmentation, was within the threshold of visually detectable change in the difference images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Self-citationMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
A survey of image registration techniques
Brown, L. G. (1992) · ACM Computing Surveys · doi:10.1145/146370.146374 · Cited by 4,057
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Self-citationMulti-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Self-citationRegistration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Freeborough, P. A., & Fox, N. C. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640753 · Cited by 382
A Registration and Interpolation Procedure for Subvoxel Matching of Serially Acquired MR Images
Hajnal, J. V., Saeed, N., Soar, E. J., Oatridge, A., Young, I. R., & Bydder, G. M. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199503000-00022 · Cited by 304
An extensible MRI simulator for post-processing evaluation
Kwan, R. K. S., Evans, A. C., & Pike, G. B. (1996) · Lecture Notes in Computer Science · doi:10.1007/bfb0046947 · Cited by 284
Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J. (1997) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.681173 · Cited by 164
Self-citationFreeborough, P. A., Woods, R. P., & Fox, N. C. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199611000-00030 · Cited by 158
Detection of Subtle Brain Changes Using Subvoxel Registration and Subtraction of Serial MR Images
Hajnal, J. V., Saeed, N., Oatridge, A., Williams, E. J., Young, I. R., & Bydder, G. M. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199509000-00001 · Cited by 154
Lemieux, L., Wieshmann, U. C., Moran, N. F., et al. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80021-2 · Cited by 140
Denton, E., Holden, M. P., Christ, E., Jarosz, J., Russell-Jones, D. L., Goodey, J., Cox, T. C. S., & Hill, D. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200001000-00025 · Cited by 26
Self-citation
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Self-citationPET-CT image registration in the chest using free-form deformations
Mattes, D., Haynor, D. R., Vesselle, H., Lewellen, T. K., & Eubank, W. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.809072 · Cited by 871
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Metadata
- Authors
- Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000
- Volume
- 19
- Issue
- 2
- Pages
- 94-102
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2133327288
- Cited by
- 277
- References
- 21
- FWCI
- 23.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.