The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Statistical image reconstruction for polyenergetic X-ray computed tomography
Open accessAbstract
This paper describes a statistical image reconstruction method for X-ray computed tomography (CT) that is based on a physical model that accounts for the polyenergetic X-ray source spectrum and the measurement nonlinearities caused by energy-dependent attenuation. We assume that the object consists of a given number of nonoverlapping materials, such as soft tissue and bone. The attenuation coefficient of each voxel is the product of its unknown density and a known energy-dependent mass attenuation coefficient. We formulate a penalized-likelihood function for this polyenergetic model and develop an ordered-subsets iterative algorithm for estimating the unknown densities in each voxel. The algorithm monotonically decreases the cost function at each iteration when one subset is used. Applying this method to simulated X-ray CT measurements of objects containing both bone and soft tissue yields images with significantly reduced beam hardening artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,877
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
(2001) · Radiology · doi:10.1148/radiology.220.2.r01au28372 · Cited by 716
Beam hardening in X-ray reconstructive tomography
Brooks, R. A., & Chiro, G. D. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/3/004 · Cited by 606
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
Self-citationPenalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Cited by
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
MoDL: Model-Based Deep Learning Architecture for Inverse Problems
Aggarwal, H. K., Mani, M. P., & Jacob, M. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2865356 · Cited by 1,069
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Deep Learning Techniques for Inverse Problems in Imaging
Ongie, G., Jalal, A., Metzler, C. A., Baraniuk, R. G., Dimakis, A. G., & Willett, R. (2020) · IEEE Journal on Selected Areas in Information Theory · doi:10.1109/jsait.2020.2991563 · Cited by 577
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Tensor-Based Formulation and Nuclear Norm Regularization for Multienergy Computed Tomography
Semerci, O., Hao, N., Kilmer, M. E., & Miller, E. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2305840 · Cited by 389
CNN-Based Projected Gradient Descent for Consistent CT Image Reconstruction
Gupta, H., Jin, K. H., Nguyen, H. Q., McCann, M. T., & Unser, M. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832656 · Cited by 380
Managing Radiation Use in Medical Imaging: A Multifaceted Challenge
Hricak, H., Brenner, D. J., Adelstein, S. J., Frush, D. P., Hall, E. J., Howell, R. W., McCollough, C. H., Mettler, F. A., Pearce, M. S., Suleiman, O. H., et al. (2011) · Radiology · doi:10.1148/radiol.10101157 · Cited by 342
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & De Man, B. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 341
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
Nonlinear sinogram smoothing for low-dose X-ray CT
Li, T., Li, X., Wang, J., Wen, J., Lu, H., Hsieh, J., & Liang, Z. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.834824 · Cited by 309
Sparse-view x-ray CT reconstruction via total generalized variation regularization
Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2997 · Cited by 291
Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., & Hsieh, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2058811 · Cited by 290
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
A review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 279
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
Structurally-Sensitive Multi-Scale Deep Neural Network for Low-Dose CT Denoising
You, C., Cong, W., Wang, G., Yang, Q., Shan, H., Gjesteby, L., Li, G., Ju, S., Zhang, Z., Zhao, Z., et al. (2018) · IEEE Access · doi:10.1109/access.2018.2858196 · Cited by 259
Wu, J., Wang, X., Mou, X., Chen, Y., & Liu, S. (2020) · Sensors · doi:10.3390/s20061647 · Cited by 9
Metadata
- Authors
- Elbakri, I. A., & Fessler, J. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002
- Volume
- 21
- Issue
- 2
- Pages
- 89-99
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2098092211
- Cited by
- 691
- References
- 38
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.