Neuroelectronic interfacing with cultured multielectrode arrays toward a cultured probe
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Efficient and selective electrical stimulation and recording of neural activity in peripheral, spinal, or central pathways requires multielectrode arrays at micrometer scale. "Cultured probe" devices are being developed, i.e., cell-cultured planar multielectrode arrays (MEAs). They may enhance efficiency and selectivity because neural cells have been grown over and around each electrode site as electrode-specific local networks. If, after implantation, collateral sprouts branch from a motor fiber (ventral horn area) and if they can be guided and contacted to each "host" network, a very selective and efficient interface will result. Four basic aspects of the design and development of a cultured probe, coated with rat cortical or dorsal root ganglion neurons, are described. First, the importance of optimization of the cell-electrode contact is presented. It turns out that impedance spectroscopy, and detailed modeling of the electrode-cell interface, is a very helpful technique, which shows whether a cell is covering an electrode and how strong the sealing is. Second, the dielectrophoretic trapping method directs cells efficiently to desired spots on the substrate, and cells remain viable after the treatment. The number of cells trapped is dependent on the electric field parameters and the occurrence of a secondary force, a fluid flow (as a result of field-induced heating). It was found that the viability of trapped cortical cells was not influenced by the electric field. Third, cells must adhere to the surface of the substrate and form networks, which are locally confined, to one electrode site. For that, chemical modification of the substrate and electrode areas with various coatings, such as polyethyleneimine (PEI) and fluorocarbon monolayers promotes or inhibits adhesion of cells. Finally, it is shown how PEI patterning, by a stamping technique, successfully guides outgrowth of collaterals from a neonatal rat lumbar spinal cord explant, after six days in culture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245 · cited 1×
“A recent example of a 3-D device is the stacked multielectrode system of the Michigan group [12].”
MethodRomijn, H. J., van Huizen, F., & Wolters, P. S. (1984) · Neuroscience & Biobehavioral Reviews · doi:10.1016/0149-7634(84)90055-1 · Cited by 209 · cited 2×
“Furthermore, R12 medium [101] is used to suppress proliferation of nonneural cells.”
BackgroundMethodEdell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · cited 1×
“grow through via holes or slits in 2-D “neural sieve” multielectrodes, the number of contact sites being limited to at most 12 [13], [14].”
BackgroundKovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Neuro-electronic interfacing with multielectrode arrays
Rutten, W. L. C., Smit, J. P. A., Frieswijk, T. A., Bielen, J. A., Brouwer, A. L. H., Buitenweg, J. R., & Heida, C. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765188 · Cited by 39
Self-citationEndoneural selective stimulating using wire-microelectrode arrays
Smit, J. P. A., Rutten, W. L. C., & Boom, H. B. K. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808943 · Cited by 20 · cited 1×
“In previous work [3]–[5], in the neuromuscular system,”
BackgroundSelf-citation
Cited by
Long-Term Characterization of Firing Dynamics of Spontaneous Bursts in Cultured Neural Networks
vanPelt, J., Wolters, P. S., Corner, M. A., Rutten, W. L. C., & Ramakers, G. J. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827936 · Cited by 292
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
“Cultured arrays may one day be used as cultured neuron probes, for example, by controlling each cell separately in a “cage” on a neurochip (100) or by controlling small networks at each electrode (101).”
MethodSelf-citationBiology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
Dynamics and plasticity in developing neuronal networks in vitro
van Pelt, J., Vajda, I., Wolters, P. S., Corner, M. A., & Ramakers, G. J. A. (2005) · Progress in Brain Research · doi:10.1016/s0079-6123(04)47013-7 · Cited by 164
“Multielectrode plates were obtained from the University of Twente, Enschede, The Netherlands (Rutten et al., 2001).”
MethodA new planar multielectrode array: recording from a rat auditory cortex
Tsytsarev, V., Taketani, M., Schottler, F., Tanaka, S., & Hara, M. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/006 · Cited by 26
Metadata
- Authors
- Rutten, W., Mouveroux, J.-M., Buitenweg, J., Heida, C., Ruardij, T., Marani, E., & Lakke, E.
- Venue
- Proceedings of the IEEE
- Published
- 2001-07
- Volume
- 89
- Issue
- 7
- Pages
- 1013-1029
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2144105614
- Cited by
- 46
- References
- 6
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neuroelectronic interfacing with cultured multielectrode arrays toward a cultured probe. https://app.cochat.ai/papers/10.1109/5.939810
- The paper
- Rutten, W., Mouveroux, J.-M., Buitenweg, J., Heida, C., Ruardij, T., Marani, E., & Lakke, E. (2001). Neuroelectronic interfacing with cultured multielectrode arrays toward a cultured probe. Proceedings of the IEEE. https://doi.org/10.1109/5.939810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.