The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Shear modulus imaging with 2-D transient elastography
Abstract
In previous works, we have shown that time-resolved 2-D transient elastography is a promising technique for characterizing the elasticity of soft tissues. It involves the measurement of the displacements induced by the propagation of low frequency (LF) pulsed shear waves in biological tissues. In this paper, we present a novel apparatus that contains a LF vibrating device surrounding a linear array of 128 ultrasonic transducers that performs ultrafast ultrasonic imaging (up to 10,000 frames/s) and that is able to follow in real time the propagation of a LF shear wave in the human body. The vibrating device is made of two rods, fixed to electromagnetic vibrators, that produce in the ultrasonic image area a large amplitude shear wave. The geometry has been chosen both to enhance the sensitivity and to create a quasi linear shear wave front in the imaging plane. An inversion algorithm is used to recover the shear modulus map from the spatio-temporal data, and the first experimental results obtained from tissue-equivalent materials are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Konofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Self-citationShattuck, D. P., Weinshenker, M. D., Smith, S. W., & von Ramm, O. T. (1984) · The Journal of the Acoustical Society of America · doi:10.1121/1.390734 · Cited by 395
Biophysical Bases of Elasticity Imaging
Sarvazyan, A. P., Skovoroda, A. R., Emelianov, S. Y., Fowlkes, J. B., Pipe, J. G., Adler, R. S., Buxton, R. B., & Carson, P. L. (1995) · Acoustical Imaging · doi:10.1007/978-1-4615-1943-0_23 · Cited by 301
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
Catheline, S., Wu, F., & Fink, M. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426907 · Cited by 282
Self-citationTime-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Self-citation2D and 3D high frame rate imaging with limited diffraction beams
Lu, J.-Y. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.655200 · Cited by 258
Diffraction field of a low frequency vibrator in soft tissues using transient elastography
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.775668 · Cited by 167
Self-citationChen, J.-F., Fowlkes, J. B., Carson, P. L., & Rubin, J. M. (1997) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(1997)8:1<89::aid-ima11>3.0.co;2-g · Cited by 103
Acoustic shear wave displacement measurement using ultrasound
Dutt, V., Kinnick, R. R., & Greenleaf, J. F. (2002) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1996.584202 · Cited by 25
Cited by
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Self-citationSupersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationUltrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052
Self-citation
Metadata
- Authors
- Sandrin, L., Tanter, M., Catheline, S., & Fink, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2002-04
- Volume
- 49
- Issue
- 4
- Pages
- 426-435
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2100297013
- Cited by
- 412
- References
- 15
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.