The effect of applied sensor contact force on pulse transit time
Open accessAbstract
Pulse transit time (PTT) is usually determined as the time interval between the peak of the electrocardiogram (ECG) R wave and a characteristic point of the peripheral pulse measured by photoplethysmography. However, it was found that the photoplethysmogram (PPG) is affected by the contact force between the photoplethysmographic sensor and the measurement site, i.e. finger. Therefore, we hypothesized that the PTT may be altered by the applied sensor contact force. An ECG and PPG were recorded simultaneously from 30 healthy subjects using 12 magnitudes of contact force (0.1 N-1.8 N). Three characteristic points of the PPG were selected to determine the PTT, including the points near the foot (PTT1), on the systole phase (PTT2) and near the peak (PTT3). Both PTT1 and PTT2 increased significantly (p = 0.014 for PTT1 and p = 0.038 for PTT2) with the sensor contact force until the transmural force reached -0.1 N. With further increase in the contact force, they kept at an almost constant level. Such a changing trend was not found in PTT3. The results of this study suggest that the applied sensor contact force should be carefully controlled in PTT measurement to avoid diminishing its value as a diagnostic tool.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For the PTT calculated at 90% of the pulse amplitude, there was a similar increasing trend for the PTT but without a significant difference (p = 0.107), and the PTT leveled out to a constant value for a transmural pressure of around 0.1 N.
“Lastly, for the PTT calculated at 90% of the pulse amplitude, there was a similar increasing trend for the PTT but without a significant difference (p = 0.107). The PTT leveled out to a constant value for a transmural pressure of around 0.1 N.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [208]
For the PTT measured from 50% of the pulse amplitude, there was a significant increase in PTT (p = 0.038) before reaching a constant at −0.1 N transmural pressure.
“For the PTT measured from 50% of the pulse amplitude, there was a significant increase in PTT (p = 0.038) before reaching a constant at −0.1 N transmural pressure.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [208]
With a contact force of 0.1-0.8 N applied at the finger, the PTT measured from the R peak of an ECG and the peak of the second derivative of the PPG increased significantly (p = 0.014) until the estimated transmural pressure approached −0.1 N, after which the PTT remained roughly constant.
“Regarding PTT, Teng and Zhang discovered that, with a contact force of 0.1–0.8 N applied at the finger, the PTT measured from the R peak of an ECG and the peak of the second derivative of the PPG increased significantly (p = 0.014) until the estimated transmural pressure approached −0.1 N, after which the PTT remained roughly constant [208].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [208]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856 · see citing works
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493 · see citing works
Association Between Arterial Stiffness and Atherosclerosis: The Rotterdam Study
van Popele, N. M., Grobbee, D. E., Bots, M. L., Asmar, R., Topouchian, J., Reneman, R. S., Hoeks, A. P. G., van der Kuip, D. A. M., Hofman, A., & Witteman, J. C. M. (2001) · Stroke · doi:10.1161/01.str.32.2.454 · Cited by 1,142 · see citing works
Determination of pulse wave velocities with computerized algorithms
Chiu, Y. C., Arand, P. W., Shroff, S. G., Feldman, T. E., & Carroll, J. D. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90153-9 · Cited by 313 · see citing works
Regional pulse-wave velocity in the arterial tree.
McDonald, D. A. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.24.1.73 · Cited by 222 · see citing works
Photoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 217 · see citing works
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217 · see citing works
Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction
Mascaro, S. A., & Asada, H. H. (2001) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.964669 · Cited by 192 · see citing works
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171 · see citing works
Self-citationThe Pulse Wave Velocity as an Early Indicator of Atherosclerosis in Diabetic Subjects
Woolam, G. L., Schnur, P., Vallbona, C., & HOFF, H. E. (1962) · Circulation · doi:10.1161/01.cir.25.3.533 · Cited by 171 · see citing works
Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
Wesseling, K. H., Settels, J. J., van der Hoeven, G. M. A., Nijboer, J. A., BUTIJN, M. W. T., & Dorlas, J. C. (1985) · Cardiovascular Research · doi:10.1093/cvr/19.3.139 · Cited by 164 · see citing works
Pulse Transit Time: Relationship to Blood Pressure and Myocardial Performance
Obrist, P. A., Light, K. C., McCubbin, J. A., Hutcheson, J. S., & Hoffer, J. L. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb02993.x · Cited by 153 · see citing works
Pulse wave velocity in patients with obesity and hypertension
Toto-Moukouo, J. J., Achimastos, A. D., Asmar, R. G., Hugues, C., & Safar, M. E. (1986) · American Heart Journal · doi:10.1016/0002-8703(86)90691-5 · Cited by 139 · see citing works
Recent Advances on Large Arteries in Hypertension
Safar, M. E., London, G. M., Asmar, R. G., & Frohlich, E. D. (1998) · Hypertension · doi:10.1161/01.hyp.32.1.156 · Cited by 121 · see citing works
Pulse Transit Time and Blood Pressure: An Intensive Analysis
Lane, J. D., Greenstadt, L., Shapiro, D., & Rubinstein, E. H. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb00899.x · Cited by 107 · see citing works
Calculation of pulse-wave velocity using cross correlation—Effects of reflexes in the arterial tree
Benthin, M., Dahl, P., Ruzicka, R., & Lindström, K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90182-v · Cited by 107 · see citing works
Oscillometric determination of diastolic, mean and systolic blood pressure—A numerical model
Forster, F. K., & Turney, D. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138629 · Cited by 104 · see citing works
Pollak, M. H., & Obrist, P. A. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb00895.x · Cited by 94 · see citing works
Pressure-diameter relationships of segments of human finger arteries
Langewouters, G. J., Zwart, A., Busse, R., & Wesseling, K. H. (1986) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/7/1/003 · Cited by 91 · see citing works
Time Domain Resolution of Forward and Reflected Waves in the Aorta
Li, J. K. ‐. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325903 · Cited by 90 · see citing works
Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D. (1985) · Anesthesiology · doi:10.1097/00000542-198503000-00022 · Cited by 84 · see citing works
Relationship between pulse-wave velocity and arterial elasticity
CALLAGHAN, F., Geddes, L. A., Babbs, C. F., & BOURLAND, J. D. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441620 · Cited by 83 · see citing works
Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
Allen, J., & Murray, A. (2000) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20000846 · Cited by 76 · see citing works
Jago, J. R., & Murray, A. (1988) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/9/4/003 · Cited by 74 · see citing works
The relationship between arterial pulse-wave velocity and pulse frequency at different pressures
CALLAGHAN, F., Babbs, C. F., BOURLAND, J. D., & Geddes, L. A. (1984) · Journal of Medical Engineering & Technology · doi:10.3109/03091908409032067 · Cited by 72 · see citing works
Forearm arterial distensibility in systolic hypertension
Smulyan, H., Vardan, S., Griffiths, A., & Gribbin, B. (1984) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(84)80024-8 · Cited by 69 · see citing works
Measurement of pulse-wave velocity using a beat-sampling technique
Pruett, J. D., BOURLAND, J. D., & Geddes, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02364622 · Cited by 53 · see citing works
On the pressure-volume relationship in circulatory elements
Hardy, H. H., & Collins, R. E. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02443403 · Cited by 47 · see citing works
The Covariation of Blood Pressure and Pulse Transit Time in Hypertensive Patients
Allen, R. A., Schneider, J. A., Davidson, D. M., Winchester, M. A., & Taylor, C. B. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb03038.x · Cited by 45 · see citing works
Noninvasive measurements of aortic stiffness: methodological considerations.
Ed, L. (1999) · PubMed · Cited by 40 · see citing works
An Arterial to Peripheral Pulse Wave Velocity Measure
Jennings, J. R., & Choi, S. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb00922.x · Cited by 27 · see citing works
Okada, M., Kimura, S., & Okada, M. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441621 · Cited by 26 · see citing works
Blood pressure evaluation based on arterial pulse wave velocity
Franchi, D., Bedini, R., Manfredini, F., Berti, S. L., Palagi, G., Ghione, S., & Ripoli, A. (2002) · Computers in cardiology · doi:10.1109/cic.1996.542557 · Cited by 24 · see citing works
Real-time measurement of pulse wave velocity from arterial pressure waveforms
Ramsey, M. W., Stewart, W. R., & Jones, C. J. H. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510780 · Cited by 22 · see citing works
Photoelectric Plethysmography Using Reflected Light
Nieveen, J. L., van der Slikke, L. B., & Reichert, W. J. (2008) · Cardiologia · doi:10.1159/000165601 · Cited by 21 · see citing works
A very sensitive photoplethysmograph using scattered light and a photosensitive resitance.
de Pater, van den Berg, M. P., & Bueno, A. A. (1962) · PubMed · Cited by 19 · see citing works
The Peripheral Pulse as a Diagnostic Tool
McLean, C. E., Clason, W. P. C., Stoughton, P. V., & McLean, C. E. (1964) · Angiology · doi:10.1177/000331976401500504 · Cited by 14 · see citing works
Estimation of arterial pulse wave velocity with a new improved tissue Doppler method
Persson, M., Eriksson, A., Persson, H. W., & Lindström, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1018884 · Cited by 12 · see citing works
A critique: relationship of the time derivative of pressure to blood flow
Greenfield, J. C., & Fry, D. L. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.6.1141 · Cited by 12 · see citing works
Comparative study of arterial transmission velocity
Malindzak, G. S., & Meredith, J. H. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90034-5 · Cited by 11 · see citing works
Driscoll, M., Malcolm, J., Arnold, O., Marchiori, G. E., Harker, L., & Sherebrin, M. H. (1997) · Clinical Science · doi:10.1042/cs0920559 · Cited by 9 · see citing works
On a non-invasive evaluation of pulse wave velocity in human peripheral arteries
Gizdulich, P. (1984) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/5/1/006 · Cited by 8 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Lee C M 2004 Cuffless blood pressure measurement with temperature compensation M Phil thesis The Chinese University of Hong Kong
Cited by
Sorted by citations
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · see citing works
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · see citing works
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. V. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 567 · see citing works
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 450 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Interoceptive awareness in experienced meditators
Khalsa, S. S., Rudrauf, D., Damasio, A. R., Davidson, R. J., Lutz, A., & Tranel, D. (2008) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00666.x · Cited by 280 · see citing works
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226 · see citing works
Wong, M. Y. M., Poon, C. C. Y., & Zhang, Y. (2009) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-009-9070-7 · Cited by 191 · see citing works
Noncontact imaging photoplethysmography to effectively access pulse rate variability
Sun, Y., Hu, S., Azorin-Peris, V., Kalawsky, R. S., & Greenwald, S. E. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061205 · Cited by 163 · see citing works
Liu, J., Yan, B. P., Zhang, Y., Ding, X., Su, P., & Zhao, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874957 · Cited by 139 · see citing works
Sun, Y., Azorin-Peris, V., Kalawsky, R. S., Hu, S., Papin, C., & Greenwald, S. E. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.3.037005 · Cited by 125 · see citing works
A Chair–Based Unobtrusive Cuffless Blood Pressure Monitoring System Based on Pulse Arrival Time
Tang, Z., TAMURA, T., Sekine, M., Huang, M., Chen, W., Yoshida, M., Sakatani, K., Kobayashi, H., & Kanaya, S. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2614962 · Cited by 91 · see citing works
Advances in Non-Invasive Blood Pressure Measurement Techniques
Panula, T., Sirkiä, J., Wong, D., & Kaisti, M. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3141877 · Cited by 70 · see citing works
A new method of continuous blood pressure monitoring using multichannel sensing signals on the wrist
Wang, L., Tian, S., & Zhu, R. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00590-4 · Cited by 67 · see citing works
Radial pulse transit time is an index of arterial stiffness
Zhang, Y., Zheng, Y.-Y., Ma, Z., & Sun, Y. (2011) · Hypertension Research · doi:10.1038/hr.2011.41 · Cited by 62 · see citing works
Chan, G. S. H., Middleton, P. M., Celler, B. G., Wang, L., & Lovell, N. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9086-8 · Cited by 62 · see citing works
Skin inhomogeneity as a source of error in remote PPG-imaging
Moço, A., Stuijk, S., & de Haan, G. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004718 · Cited by 57 · see citing works
Kim, S., Song, J., Park, J.-H., Kim, J., Park, Y., & Hwang, G. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318270a6d9 · Cited by 54 · see citing works
Liu, J., Zhang, Y., Ding, X., Dai, W., & Zhao, N. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590777 · Cited by 41 · see citing works
Wong, M. Y. M., Pickwell‐MacPherson, E., & Zhang, Y. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1112-8 · Cited by 38 · see citing works
Wang, H., Wang, L., Sun, N., Yao, Y., Hao, L., Xu, L., & Greenwald, S. E. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01563 · Cited by 36 · see citing works
Wang, L., Poon, C. C. Y., & Zhang, Y. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/008 · Cited by 33 · see citing works
van Velzen, M. H. N., Loeve, A. J., Niehof, S. P., & Mik, E. G. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1642-x · Cited by 34 · see citing works
A review: Blood pressure monitoring based on PPG and circadian rhythm
Chen, G., Zou, L., & Ji, Z. (2024) · APL Bioengineering · doi:10.1063/5.0206980 · Cited by 34 · see citing works
McCombie, D. B., Reisner, A. T., & Asada, H. H. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649321 · Cited by 30 · see citing works
The Role of Pulse Transit Time as an Index of Arterial Stiffness During Exercise
Kounalakis, S. N., & Geladas, N. D. (2009) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-009-9081-4 · Cited by 28 · see citing works
Contactless and Cuffless Monitoring of Blood Pressure on a Chair Using E-Textile Materials
Wu, K.-F., Chan, C.-H., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmdbs.2006.360107 · Cited by 28 · see citing works
Heart rate extraction from photoplethysmogram on fuzzy logic discriminator
Liu, S.-H., Chang, K.-M., & Fu, T.-H. (2010) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2010.02.008 · Cited by 26 · see citing works
Contactless and continuous monitoring of heart rate based on photoplethysmography on a mattress
Wong, M. Y. M., Pickwell‐MacPherson, E., & Zhang, Y. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/7/014 · Cited by 26 · see citing works
Middleton, P. M., Chan, G. S. H., O’Lone, E., Steel, E., Carroll, R., Celler, B. G., & Lovell, N. H. (2009) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00843.x · Cited by 23 · see citing works
Piezoresistive Soft Condensed Matter Sensor for Body-Mounted Vital Function Applications
Melnykowycz, M., Tschudin, M., & Clemens, F. J. (2016) · Sensors · doi:10.3390/s16030326 · Cited by 23 · see citing works
Estimation of Heart Rate and Respiratory Rate using Imaging Photoplethysmography Technique
Singh, N., & Raj, A. A. B. (2020) · International Conference on System, Computation, Automation and Networking (ICSCAN) · doi:10.1109/icscan49426.2020.9262320 · Cited by 21 · see citing works
Investigating the impact of contact pressure on photoplethysmograms
Sirkiä, J., Panula, T., & Kaisti, M. (2024) · Biomedical Engineering Advances · doi:10.1016/j.bea.2024.100123 · Cited by 22 · see citing works
Comparison of bilateral pulse arrival time before and after induced vasodilation by axillary block
Kortekaas, M. C., Niehof, S. P., van Velzen, M. H. N., Galvin, E. M., Stolker, R. J., & Huygen, F. J. P. M. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/12/1993 · Cited by 21 · see citing works
Liao, S., Liu, H., Lin, W.-H., Zheng, D., & Chen, F. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1172150 · Cited by 11 · see citing works
van Velzen, M. H. N., Loeve, A. J., Kortekaas, M. C., Niehof, S. P., Mik, E. G., & Stolker, R. J. (2015) · Physiological Measurement · doi:10.1088/0967-3334/37/1/52 · Cited by 11 · see citing works
Wong, M. Y. M., Poon, C. C. Y., & Zhang, Y. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259873 · Cited by 9 · see citing works
Photoplethysmographic Assessment of Hemodynamic Variations Using Pulsatile Tissue Blood Volume
Foo, J. Y. A., Lim, C. S., & Wilson, S. J. (2008) · Angiology · doi:10.1177/0003319708314245 · Cited by 8 · see citing works
Zhang, Y., Ma, Z., Lung, C.-W., Sun, Y., & LI, X.-H. (2012) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519412500285 · Cited by 7 · see citing works
Dhillon, M. S., & Banet, M. J. (2019) · Springer eBooks · doi:10.1007/978-3-030-24701-0_5 · Cited by 5 · see citing works
Towards PPG-based anger detection for emotion regulation
How, T.-V., Green, R., & Mihailidis, A. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01217-5 · Cited by 5 · see citing works
Practicality and importance of selected endothelial dysfunction measurement techniques: review
Whitt, M. D., & Jackson, M. J. (2018) · Biomedical Engineering Letters · doi:10.1007/s13534-018-0089-9 · Cited by 5 · see citing works
A chair for cuffless real-time estimation of systolic blood pressure based on pulse transit time
Tang, Z., Sekine, M., TAMURA, T., Yoshida, M., & Chen, W. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319543 · Cited by 5 · see citing works
Photoplethysmogram analysis and applications: An Integrative Review (Preprint)
Shin, H., Park, J., Seok, H. S., & Kim, S. (2020) · JMIR Biomedical Engineering · doi:10.2196/25567 · Cited by 4 · see citing works
Reliability of Hemodynamic Parameters Measured by a Novel Photoplethysmography Device
Grabovskis, A., Kviesis-Kipge, E., Marcinkevičs, Z., Lusa, V., Volceka, K., & Grēve, M. (2011) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-21683-1_50 · Cited by 4 · see citing works
Ding, X., Yan, B. P., Zhang, Y., Liu, J., Su, P., & Zhao, N. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037304 · Cited by 4 · see citing works
Contact Force Estimation from Raw Photoplethysmogram Signal
Fortin, P. E., Blum, J. R., Weill–Duflos, A., & Cooperstock, J. R. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278658 · Cited by 2 · see citing works
The Changes in Pulse Transit Time at Specific Cuff Pressures during Inflation and Deflation
Liu, Y., Poon, C. C. Y., & Zhang, Y. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260410 · Cited by 2 · see citing works
van Velzen, M. H. N., Niehof, S. P., Mik, E. G., & Loeve, A. J. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab3ad8 · Cited by 2 · see citing works
Celik, N. (2017) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 2 · see citing works
Gama, C. (2015) · City Research Online (City University London) · Cited by 1 · see citing works
Measurement of the arterial pulse wave with biomagnetic technique
Córdova–Fraga, T., Huerta, C., Sosa, M., Huerta, R., Vargas, M., Hernández, E., & Bernal, J. J. (2007) · International Congress Series · doi:10.1016/j.ics.2006.12.074
- Authors
- Teng, X. F., & Zhang, Y. T.
- Affiliations
- Chinese University of Hong Kong (HK)
- ORCID
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2006-05-26
- Volume
- 27
- Issue
- 8
- Pages
- 675-684
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2012152853
- Cited by
- 53
- References
- 42
- Citations by year
- 2024: 2 · 2023: 3 · 2022: 2 · 2021: 1 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 5 · 2012: 6
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Innovation and Technology Fund
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- pulse transit time, photoplethysmography, finger photoplethysmography, peripheral pulses, measurement artifacts
- MeSH terms
- Adult, Blood Pressure, Body Temperature, Electrocardiography, Female, Heart Rate, Humans, Male, Pulsatile Flow, Pulse, Time, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review