The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Information transfer rate in a five-classes brain-computer interface
Abstract
The information transfer rate, given in bits per trial, is used as an evaluation measurement in a brain-computer interface (BCI). Three subjects performed four motor-imagery (left hand, right hand, foot, and tongue) and one mental-calculation task. Classification of the electroencephalogram (EEG) patterns is based on band power estimates and hidden Markov models (HMMs). We propose a method that combines the EEG patterns based on separability into subsets of two, three, four, and five mental tasks. The information transfer rates of the BCI systems comprised of these subsets are reported. The achieved information transfer rates vary from 0.42 to 0.81 bits per trial and reveal that the upper limit of different mental tasks for a BCI system is three. In each subject, different combinations of three tasks resulted in the best performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
Introduction to Statistical Pattern Recognition
(1990) · Elsevier eBooks · doi:10.1016/c2009-0-27872-x · Cited by 11,031
The Mathematical Theory of Communication
Shannon, C. E., Weaver, W., & Wiener, N. (1950) · Physics Today · doi:10.1063/1.3067010 · Cited by 9,801
Fundamentals of speech recognition
Rabiner, L. R., & Juang, B.-H. F. (1993) · Cited by 7,680
Mathematical Theory of Communication
(2013) · Encyclopedia of Systems Biology · doi:10.1007/978-1-4419-9863-7_100015 · Cited by 3,290
Discrete-Time Processing of Speech Signals
Deller, J. R., Hansen, J. H. L., & Proakis, J. G. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544402 · Cited by 2,458
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 1×
“N INTERFACE between the human brain and the computer was recently introduced as a spelling device [ 1 ] for a patient suffering from amyotrophic lateral sclerosis (ALS).”
MethodMotor imagery activates primary sensorimotor area in humans
Pfurtscheller, G., & Neuper, C. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00889-6 · Cited by 1,051
Self-citation
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Bashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Dornhege, G., Blankertz, B., Curio, G., & Muller, K.-R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827088 · Cited by 631
Control of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589
Self-citationBrain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Hand Movement Direction Decoded from MEG and EEG
Waldert, S., Preissl, H., Demandt, E., Braun, C., Birbaumer, N., Aertsen, A., & Mehring, C. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.5171-07.2008 · Cited by 415
Brain-computer communication: Self-regulation of slow cortical potentials for verbal communication
Kübler, A., Neumann, N., Kaiser, J., Kotchoubey, B., Hinterberger, T., & Birbaumer, N. P. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26621 · Cited by 350
Neuper, C., Müller, G. R., Kübler, A., Birbaumer, N., & Pfurtscheller, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00387-5 · Cited by 317
Self-citationA Multi-Branch 3D Convolutional Neural Network for EEG-Based Motor Imagery Classification
Zhao, X., Zhang, H., Zhu, G., You, F., Kuang, S., & Sun, L. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2938295 · Cited by 305
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Steady-state somatosensory evoked potentials: suitable brain signals for brain-computer interfaces?
Muller-Putz, G. R., Scherer, R., Neuper, C., & Pfurtscheller, G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.863842 · Cited by 288
Self-citationMahmood, M., Mzurikwao, D., Kim, Y.-S., Lee, Y., Mishra, S., Herbert, R., Duarte, A., Ang, C. S., & Yeo, W.-H. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0091-7 · Cited by 181
Benchmarking Brain-Computer Interfaces Outside the Laboratory: The Cybathlon 2016
Novak, D., Sigrist, R., Gerig, N. J., Wyss, D., Bauer, R., Götz, U., & Riener, R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00756 · Cited by 41
Metadata
- Authors
- Obermaier, B., Neuper, C., Guger, C., & Pfurtscheller, G.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-09
- Volume
- 9
- Issue
- 3
- Pages
- 283-288
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2115854344
- Cited by
- 337
- References
- 19
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.