The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs
Open accessAbstract
This paper examines the spatial resolution properties of penalized-likelihood image reconstruction methods by analyzing the local impulse response. The analysis shows that standard regularization penalties induce space-variant local impulse response functions, even for space-invariant tomographic systems. Paradoxically, for emission image reconstruction, the local resolution is generally poorest in high-count regions. We show that the linearized local impulse response induced by quadratic roughness penalties depends on the object only through its projections. This analysis leads naturally to a modified regularization penalty that yields reconstructed images with nearly uniform resolution. The modified penalty also provides a very practical method for choosing the regularization parameter to obtain a specified resolution in images reconstructed by penalized-likelihood methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of digital image processing
Jain, A. K. (1988) · Cited by 7,111
Fundamentals of digital image processing
(1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(89)90041-8 · Cited by 4,677
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
A Method for Attenuation Correction in Radionuclide Computed Tomography
Chang, L.-T. (1978) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1978.4329385 · Cited by 1,297
A generalized Gaussian image model for edge-preserving MAP estimation
Bouman, C., & Sauer, K. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.236536 · Cited by 884
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Self-citationGalatsanos, N. P., & Katsaggelos, A. K. (1992) · IEEE Transactions on Image Processing · doi:10.1109/83.148606 · Cited by 500
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
A unified approach to statistical tomography using coordinate descent optimization
Bouman, C. A., & Sauer, K. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491321 · Cited by 442
Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography
Snyder, D. L., Miller, M. I., Thomas, L. J., & Politte, D. G. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307831 · Cited by 421
Cited by
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Self-citationA three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
The EM Algorithm—an Old Folk-song Sung to a Fast New Tune
Meng, X.-L., & Van Dyk, D. (1997) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00082 · Cited by 802
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Self-citationIterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities
Sutton, B. P., Noll, D. C., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808360 · Cited by 397
Self-citationHernando, D., Kellman, P., Haldar, J. P., & Liang, Z. ‐. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22177 · Cited by 336
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Self-citationShen, L., Zhao, W., & Xing, L. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0466-4 · Cited by 313
Image Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
Self-citationSimultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
Rezaei, A., Defrise, M., Bal, G., Michel, C., Conti, M., Watson, C., & Nuyts, J. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2212719 · Cited by 261
A Splitting-Based Iterative Algorithm for Accelerated Statistical X-Ray CT Reconstruction
Ramani, S., & Fessler, J. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2175233 · Cited by 257
Self-citation
Metadata
- Authors
- Fessler, J. A., & Rogers, W. L.
- Venue
- IEEE Transactions on Image Processing
- Published
- 1996-09
- Volume
- 5
- Issue
- 9
- Pages
- 1346-1358
- ISSN
- 1057-7149 (ISSN-L)
- 1941-0042
- OpenAlex
- W2121570028
- Cited by
- 518
- References
- 26
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.