Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles

Haugland, M.K., Hoffer, J.A. · 1994 · IEEE Transactions on Rehabilitation Engineering
Cited by 50

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Restoration of the voluntary use of paralyzed limbs using functional neuromuscular stimulation (FNS) is limited by complex muscle properties and unpredictable load behaviors; closed-loop control of FNS would improve performance but requires reliable sensory feedback modalities. Sensory nerve signals recorded by cuff electrodes provide accurate information about forces acting on the skin in anesthetized animals; however, nerve cuff signals are very small (approximately 10 /spl mu/V), and during FNS they become contaminated with large stimulation artifacts and synchronous EMG potentials from nearby muscles. The authors show in this study that it is possible to record neural signals from the cat tibial nerve without interference from distributed stimulation of four calf muscles surrounding the recording electrode by use of high-pass filtering and synchronized bin-integration. Nerve signals sampled in this way retained all the information about footpad contact force that was normally obtained in the absence of muscle stimulation. The authors propose that this approach has wide applicability for rehabilitation of paralyzed people with neural prostheses.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.296344

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 50

Metadata

Authors
Haugland, M. K., & Hoffer, J. A.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
1994-03
Volume
2
Issue
1
Pages
37-40
ISSN
1063-6528 (ISSN-L)
OpenAlex
W2122845088
Cited by
50
References
3
FWCI
1.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles. https://app.cochat.ai/papers/10.1109/86.296344
The paper
Haugland, M. K., & Hoffer, J. A. (1994). Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.296344

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.