Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Restoration of the voluntary use of paralyzed limbs using functional neuromuscular stimulation (FNS) is limited by complex muscle properties and unpredictable load behaviors; closed-loop control of FNS would improve performance but requires reliable sensory feedback modalities. Sensory nerve signals recorded by cuff electrodes provide accurate information about forces acting on the skin in anesthetized animals; however, nerve cuff signals are very small (approximately 10 /spl mu/V), and during FNS they become contaminated with large stimulation artifacts and synchronous EMG potentials from nearby muscles. The authors show in this study that it is possible to record neural signals from the cat tibial nerve without interference from distributed stimulation of four calf muscles surrounding the recording electrode by use of high-pass filtering and synchronized bin-integration. Nerve signals sampled in this way retained all the information about footpad contact force that was normally obtained in the absence of muscle stimulation. The authors propose that this approach has wide applicability for rehabilitation of paralyzed people with neural prostheses.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
McGill, K. C., Cummins, K. L., Dorfman, L. J., Berlizot, B. B., Luetkemeyer, K., Nishimura, D. G., & Widrow, B. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.325019 · Cited by 143
Long‐term effects of axotomy on neural activity during cat locomotion.
Gordon, T., Hoffer, J. A., Jhamandas, J., & Stein, R. B. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013283 · Cited by 65
Self-citation
Cited by
Shon, A., Chu, J.-U., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Upshaw, B., & Sinkjaer, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681183 · Cited by 74
Inmann, A., & Haugland, M. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.003 · Cited by 40
Self-citationJensen, W., Sinkjaer, T., & Sepulveda, F. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802851 · Cited by 26
“The ENG signals were rectified, bin-integrated over 12.5 ms windows and low-pass filtered at 10 Hz. If stimulation artifacts were present in the recordings, they were blanked out by integrating the ENG signals over a 9-ms artifact-free window occurring between stimulations as described in [ 12 ].”
MethodInfluential
Metadata
- Authors
- Haugland, M. K., & Hoffer, J. A.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1994-03
- Volume
- 2
- Issue
- 1
- Pages
- 37-40
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2122845088
- Cited by
- 50
- References
- 3
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.