Electronic design of a cochlear implant for multichannel high-rate pulsatile stimulation strategies
The DOI matches its Crossref record.
Abstract
A new electronic design for an eight-channel cochlear implant for high-rate pulsatile stimulation strategies is presented. Symmetric biphasic current pulses can be generated up to a maximum pulse repetition rate of about 12 kpulses/s. The stimulation pulse amplitude can be selected within the range of 1.5 /spl mu/A-1.5 mA. The implant contains a single mixed analog/digital CMOS-ASIC for data synchronization and stimulus generation. Stimulation signals are applied via a monopolar intracochlear multielectrode array. Output capacitors are employed for safety reasons. A back-telemetry system for measuring electrode voltages and the implant supply voltage is incorporated. Data and power are transcutaneously transferred to the implant, using a single rf-channel. The overall data rate is 400 kb/s.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Loizou, P. C. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.708543 · Cited by 326
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants
Ghovanloo, M., & Najafi, K. (2004) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2004.838144 · Cited by 290
Optogenetic stimulation of the auditory pathway
Hernandez, V. H., Gehrt, A., Reuter, K., Jing, Z., Jeschke, M., Mendoza Schulz, A., Hoch, G., Bartels, M., Vogt, G., Garnham, C. W., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci69050 · Cited by 188
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118
“These currents are driven through the load, , representing the nerve-electrode impedance, by the control of switches and . When only a single supply is available [Fig. 2(b)], the anodic and cathodic currents are generated from a single current sink by reversing the current paths using switches [ 7 ], [26].”
BackgroundGuo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43
Optical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40
Metadata
- Authors
- Zierhofer, C. M., Hochmair-Desoyer, I. J., & Hochmair, E. S.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1995-03
- Volume
- 3
- Issue
- 1
- Pages
- 112-116
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2169637280
- Cited by
- 150
- References
- 0
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.