Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Among the treatments to enhance the bladder voiding, the sacral roots neurostimulation is one of the most promising techniques. The electrostimulation of sacral nerves provokes a simultaneous contraction of the detrusor muscle as well as the external urethral sphincter (EUS). A new simplified-architecture implantable stimulator with its wireless controller have been designed to investigate high-frequency inhibition stimulation strategies. This innovative technique based on high-frequency inhibition reduces sphincter activity during stimulation. Low-frequency current pulses also applied to the sacral roots induces contraction of the detrusor muscle resulting in low pressure voiding. Chronic experiments were carried out on ten male mongrel paraplegic dogs. One cuff electrode was implanted along with each stimulator for eight months. The animals were stimulated twice a day using the prototypes of our implantable selective stimulator while voided and residual urine volume were measured during the procedure. These experiments revealed that the proposed stimulation strategy enhances bladder voiding by more than 50% in comparison with low-frequency only stimulation. The residual urine volume was reduced to an average of 9% and low pressure micturition was achieved as shown by weekly cystourethrogram.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318 · cited 1×
“• Medtronic: an implant programmable by two devices (physician full range programming and patient amplitude programmer).”
BackgroundSelective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222 · cited 1×
“More recently, our team proposed a new stimulator based on a simplified architecture which is dedicated to selective stimulation applications.”
BackgroundBrummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Cited by
Shon, A., Chu, J.-U., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors
Liu, X., Demosthenous, A., & Donaldson, N. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003199 · Cited by 118
Control of urinary bladder function with devices: successes and failures
Gaunt, R. A., & Prochazka, A. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(05)52011-9 · Cited by 105
Metadata
- Authors
- Boyer, S., Sawan, M., Abdel-Gawad, M., Robin, S., & Elhilali, M. M.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 2000
- Volume
- 8
- Issue
- 4
- Pages
- 464-470
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2156021100
- Cited by
- 77
- References
- 3
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.