New and Emerging Energy Sources for Implantable Wireless Microdevices
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this paper, we review new and emerging energy sources for wireless implantable microdevices. After a brief historical background, we review the developments in power sources in the decades following the pioneering works of Zworykin and Mackay in the late 1950s. These include deployment of lithium batteries and inductive powering in the 1970s, which resulted in significant growth and commercialization of implantable medical devices, such as cardiac pacemakers and cochlear implants. Recent research in nanoscale materials for energy generation has created intriguing possibilities for next generation implantable power sources in the form of flexible and biodegradable batteries and supercapacitors. In addition, energy harvesting/remote powering from various environmental physical and chemical sources within the body utilizing nanoscale materials can also offer unique possibilities for autonomous implantable microscale and nanoscale devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975 · cited 1×
“More recently, the technique has been adopted to scavenge energy from the motion of internal organs, including heart [13], [40], [41].”
MethodHwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672 · cited 6×
“suggest [40] this technology still needs further development, in particular with respect to higher electromechanical coefficient piezoelectric materials that are biocompatible.”
BackgroundMethodInfluentialWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 5×
“As a result, mid-field power transmission enabled the miniaturization of implant receiver down to 2 mm, Figure 8-b [54].”
BackgroundMethodInfluentialAn implantable power supply with an optically rechargeable lithium battery
Goto, K., Nakagawa, T., Nakamura, O., & Kawata, S. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930908 · Cited by 159 · cited 1×
“Their various implementations can be classified into one of two categories: inductive and acoustic/ultrasonic powering (although some limited work have also been performed on using near infrared to power implantable devices, their limited penetration depth constrains them to subcutaneous and shallow implants [48]).”
BackgroundFirst clinical experience with BION implants for therapeutic electrical stimulation
Salter, A.-C. D., Bagg, S. D., Creasy, J. L., Romano, C., Romano, D., Richmond, F. J. R., & Loeb, G. E. (2004) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2004.04005.x · Cited by 66
Cited by
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Wireless Charging Techniques for UAVs: A Review, Reconceptualization, and Extension
Lu, M., Bagheri, M., James, A. P., & Phung, T. (2018) · IEEE Access · doi:10.1109/access.2018.2841376 · Cited by 257
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Active photonic wireless power transfer into live tissues
Kim, J., Seo, J., Jung, D., Lee, T., Ju, H., Han, J., Kim, N., Jeong, J., Cho, S., Seol, J. H., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2002201117 · Cited by 75
Metadata
- Authors
- Kim, A., Ochoa, M., Rahimi, R., & Ziaie, B.
- Venue
- IEEE Access
- Published
- 2015
- Volume
- 3
- Pages
- 89-98
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2040559297
- Cited by
- 83
- References
- 5
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.