Challenges in Scaling Down of Free-Floating Implantable Neural Interfaces to Millimeter Scale
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Implantable neural interface devices are an emerging technology for continuous brain monitoring and brain-computer interface (BCI). Recording of electrical signals from neurons of interest has led to more efficient and personalized diagnosis, treatment, and prognosis of neurological disorders. It facilitates the dynamic mapping of the whole brain, improving our understanding of the links between brain functions and behaviors. Stimulation of targeted nerves and neurons has been utilized as an effective therapy for Parkinson's disease, essential tremor, dystonia, etc. It has also been developed as motor neuroprosthetic devices, improving the quality of life of many. Although initial designs were bulky, recent advances in semiconductor and nano-, micro-technology has enabled the miniaturization of such devices to the millimeter scale. Free-floating neural implants of miniature size are highly scalable to be distributed around the targeted region of interest more extensively. They are more clinically viable as they cause less disturbance to the body and induce less tissue immune response. However, these research efforts for scaling down have faced challenges resulted from decreasing the size of such implants, including issues pertaining to wireless powering, data communication, neural signal recording, and neural stimulation. Through extensive literature research and simulations, the limits and trade-offs regarding neural implant miniaturization are investigated and analyzed for each aspect of the challenges. State-of-the-art development and future trends for advanced neural interfaces are also explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008 · cited 1×
“through tissues mainly results from absorption and scattering, and is a factor of the light wavelength, amounts of absorbing chromophores, and tissue type [88].”
BackgroundOptogenetics in neural systems
Yizhar, O., Fenno, L. E., Davidson, T. J., Mogri, M., & Deisseroth, K. (2011) · Neuron · doi:10.1016/j.neuron.2011.06.004 · Cited by 1,881
Closed-Loop Deep Brain Stimulation Is Superior in Ameliorating Parkinsonism
Rosin, B., Slovik, M., Mitelman, R., Rivlin-Etzion, M., Haber, S. N., Israel, Z., Vaadia, E., & Bergman, H. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.023 · Cited by 793 · cited 1×
“To accurately determine the timing and intensity of the stimulation so that individual needs can be catered, an autonomous closed-loop electrical control platform that synchronizes the recording and stimulating systems is needed [161], [162].”
BackgroundRevealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705 · cited 2×
“Firstly, decreasing the size of stimulating implants necessitates the miniaturization of electrodes, and inevitably, increased impedance of the electrodes [10], [163] and”
BackgroundMethodBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · cited 1×
“Undesirable brain immune responses against implants will not only significantly impact signal sensitivity and clarity and the sensor’s life time, but also endanger patient’s health and well-being [23].”
BackgroundA micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · cited 3×
“The output power density is dependent on the frequency of the EM wave and should not exceed 10 mW/cm2 [34].”
BackgroundMethodA jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
Vagus nerve stimulation, side effects, and long-term safety
Ben-Menachem, E. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200109000-00005 · Cited by 400 · cited 1×
“Vagus nerve stimulation (VNS) delivers electrical impulses to the whole vagus nerve, which contains around 100,000 neural fibers, each having various functions and connecting to different organs [24], [26].”
BackgroundAn Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
Cited by
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Implantable brain machine interfaces: first-in-human studies, technology challenges and trends
Rapeaux, A. B., & Constandinou, T. G. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.10.001 · Cited by 119
Recent progress on peripheral neural interface technology towards bioelectronic medicine
Cho, Y., Park, J., Lee, C., & Lee, S. (2020) · Bioelectronic Medicine · doi:10.1186/s42234-020-00059-z · Cited by 55
Moon, E., Barrow, M., Lim, J., Lee, J., Nason, S. R., Costello, J., Kim, H. S., Chestek, C., Jang, T., Blaauw, D., et al. (2021) · ACS Photonics · doi:10.1021/acsphotonics.1c00160 · Cited by 31
“Analogous to the last kilometer/mile problem in transportation and telecommunications, there is a fundamental challenge 8 in bridging the “ last millimeter ” between the neural motes and the repeater to achieve wireless power and data transfer that meets the complex demands for sensing,…”
Background
Metadata
- Authors
- Yang, K.-W., Oh, K., & Ha, S.
- Venue
- IEEE Access
- Published
- 2020
- Volume
- 8
- Pages
- 133295-133320
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W3039890069
- Cited by
- 32
- References
- 28
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.