Operation of a phase locked loop system under distorted utility conditions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Operation of a three phase-phase locked loop-system under distorted utility conditions is presented. A control model of the PLL system is developed and and used for time and frequency domain analysis, and recommendations are made on tuning of this model specially for operation under common utility distortions as: line notching, voltage unbalance/loss, frequency variations. The PLL is completely implemented in software. All analytical results are experimentally verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
Phase-Locked Loop Circuit Design
Wolaver, D. H. (1991) · International Linear Collider · Cited by 303
Cited by
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712059 · Cited by 842
D’Arco, S., Suul, J. A., & Fosso, O. B. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.01.001 · Cited by 704
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines
Golestan, S., Ramezani, M., Guerrero, J. M., Freijedo, F. D., & Monfared, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273461 · Cited by 564
Guo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475
Comparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581980 · Cited by 347
Performance evaluation of PLL algorithms for single-phase grid-connected systems
Silva, S. M., Lopes, B. M., Cardoso Filho, B. J., Campana, R. P., & Boaventura, W. C. (2004) · Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting. · doi:10.1109/ias.2004.1348790 · Cited by 343
Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines
Leon, A. E., & Solsona, J. A. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2327197 · Cited by 316
Kesler, M., & Ozdemir, E. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2100330 · Cited by 311
Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review
Panigrahi, R., Mishra, S. K., Srivastava, S. C., Srivastava, A. K., & Schulz, N. N. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2979789 · Cited by 214
“These PLLs require a set of mutually exclusive vectors (α, β) to transform the information into the d–q domain [70].”
BackgroundGrid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions
Luna, A., Rocabert, J., Candela, J. I., Hermoso, J. R., Teodorescu, R., Blaabjerg, F., & Rodriguez, P. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2391436 · Cited by 201
“In the actual grid code requirements (GCRs), special constraints for the operation of such plants under grid voltage fault conditions have gained a great importance.”
BackgroundVarajao, D., Araujo, R. E., Miranda, L. M., & Lopes, J. A. P. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2752123 · Cited by 167
“The SRF phase-locked loop (PLL) has proven to be robust against phase unbalancing, harmonics, and voltage distortions [43].”
BackgroundVoltage and Frequency Regulation of Microgrid With Battery Energy Storage Systems
Zhao, H., Hong, M., Lin, W., & Loparo, K. A. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2741668 · Cited by 166
“The additional variable i does not have a physical meaning but is defined to facilitate the model development [31].”
BackgroundFast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- Kaura, V., & Blasko, V.
- Venue
- Proceedings of Applied Power Electronics Conference. APEC '96
- Publisher
- IEEE
- Published
- 2002-12-23
- Volume
- 2
- Pages
- 703-708
- OpenAlex
- W2115102890
- Cited by
- 903
- References
- 2
- FWCI
- 18.87
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.