Fault detection of eccentricity and bearing damage in a PMSM by means of wavelet transforms decomposition of the stator current
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
This paper presents the study of permanent magnet synchronous machines (PMSM) running with eccentricity and bearings damage. The objective is to detect and identify the fault through the current signature analysis. The stator current has been analyzed by means of both Fourier (FFT) and Discrete Wavelet (DWT) transforms. Simulations have been carried out with a two-dimensional (2-D) finite element analysis (FEA), and they have been also compared with experiments. The results prove that the method proposed can be used to identify mechanical faults in a PMSM.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The basic diagnostic signals in eccentricity diagnosis are: stator current [135], [143]- [146], [150], [151], [156]- [159], [161], [162], mechanical vibrations [149], [155], [156], noise [155], an airgap search coil voltage [149], [152], [156], [160], stator voltage [159], speed [159], load torque [159], d-axis stator inductance Ld [147], [148], BEMF [160] and unbalanced magnetic pull [153], [154]”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [135]
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227 · cited 1×
“The wavelet approach is essentially an adjustable window Fourier spectral analysis with the following general definition [13] is continuous Wavelet transforms (CWT):”
BackgroundCondition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 5×
“On the other hand, dynamic eccentricity can be caused by misalignment of bearings, mechanical resonance at critical speeds, a bent rotor shaft, wear of bearings, and others reasons [2, 3]. In reality, both static and dynamic eccentricities tend to coexist [ 4 ].”
BackgroundMethodInfluentialA review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Pillay, P., & Krishnan, R. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.25541 · Cited by 920 · cited 1×
“In addition, the equation used to solve the rotor speed, ωr, is well-known and given as [23]:”
MethodCondition monitoring and fault diagnosis of electrical machines-a review
Nandi, S., & Toliyat, H. A. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.799956 · Cited by 531 · cited 2×
“Apart from normal internal operating stresses, other causes of bearing damages due to vibration, inherent eccentricity, and bearing currents [5] due to solid state drives appear as well.”
BackgroundNandi, S., Ahmed, S., & Toliyat, H. A. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.937205 · Cited by 340
Nandi, S., Ahmed, S., & Toliyat, H. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311622 · Cited by 298 · cited 1×
“Also, Nandi et al. [ 14 ], and Ferrah et al. [15] shows that only a particular combination of machine pole pairs and rotor slot number will give rise to significant only static or only dynamic eccentricity-related components.”
BackgroundStack, J. R., Habetler, T. G., & Harley, R. G. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.827454 · Cited by 290 · cited 2×
“The characteristic fault frequencies are the result of the absolute motion (vibration) of the machine [17].”
BackgroundYazici, B., & Kliman, G. B. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.753640 · Cited by 266 · cited 1×
“[20, 21] have reported an adaptive, statistical time frequency method for the detection of bearing faults.”
MethodAn Amplitude Modulation Detector for Fault Diagnosis in Rolling Element Bearings
Stack, J. R., Harley, R. G., & Habetler, T. G. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.834971 · Cited by 224 · cited 1×
“As with the air-gap eccentricity, these variations generate stator currents at frequencies given by [18, 19].”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[116], [131], [132], [135]-[137] Stator current FFT fb =fs±kfu fu – characteristic failure frequency of the bearing k=1,2,3.”
BackgroundMethodInfluentialHong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
“Therefore, there has been a lot of research activity in the last 5-6 years on developing techniques for detecting PM demagnetization and eccentricity faults for improving the performance, reliability, and efficiency of PMSM drive systems [ 4-10 ].”
BackgroundMethodInfluentialFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
“And they also focused on mechanical faults [70].”
BackgroundHaddad, R. Z., & Strangas, E. G. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2558183 · Cited by 158
“These methods can be categorized as: time domain methods, frequency analysis methods as in [1]–[5], and time scale analysis methods such as discrete or continuous wavelet transform (D/CWT) [6], [7].”
BackgroundMethodPark, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116
“operating under non-stationary conditions, where the input frequency or load varies [9], [10].”
BackgroundMoosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Kang, K., Song, J., Kang, C., Sung, S., & Jang, G. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2686376 · Cited by 91
Park, Y., Yang, C., Lee, S. B., Lee, D.-M., Fernández, D., Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2911252 · Cited by 79
A review of Permanent Magnet Synchronous Motor fault diagnosis
ZhifuWang, Yang, J., Ye, H., & Zhou, W. (2014) · 2014 IEEE Conference and Expo Transportation Electrification Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2014.6940870 · Cited by 62
Picot, A., Obeid, Z., Régnier, J., Poignant, S., Darnis, O., & Maussion, P. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.006 · Cited by 60
“These techniques are mainly based on the analysis of the stator current spectral content assessed by time–frequency [13,15] or time-scale techniques [16].”
Sayed, W. E., Abdel-Geliel, M., & Lotfy, A. (2020) · Energies · doi:10.3390/en13112972 · Cited by 60
Sergakis, A., Salinas, M., Gkiolekas, N., & Gyftakis, K. N. (2025) · Energies · doi:10.3390/en18051177 · Cited by 58
Haddad, R. Z., & Strangas, E. G. (2013) · 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2013.6645703 · Cited by 46
Aggarwal, A., Allafi, I. M., Strangas, E. G., & Agapiou, J. S. (2020) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3006016 · Cited by 39
“References [2] and [3] used subharmonics present in stator current signals using wavelet transform and both wavelet transform and FFT, respectively.”
Review of Detection Methods of Static Eccentricity for Interior Permanent Magnet Synchronous Machine
Aggarwal, A., & Strangas, E. G. (2019) · Energies · doi:10.3390/en12214105 · Cited by 27
Obeid, Z., Poignant, S., Régnier, J., & Maussion, P. (2011) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2011.6119621 · Cited by 26
“However, a few work deals with bearing fault detection in permanent magnet machines [10][11].”
BackgroundAnalysis of Unbalanced Magnetic Pull in PMSM Due to Static Eccentricity
Aggarwal, A., Strangas, E. G., & Agapiou, J. (2019) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2019.8912268 · Cited by 22
Online Short-Circuit Current Estimation of Permanent Magnet Motors
Li, C., Baruti, K. H., & Akin, B. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3195487 · Cited by 22
“Most of the time, electric machines are exposed to high temperature, vibration, and chemicals, which trigger various faults [1]–[4].”
BackgroundGherabi, Z., Toumi, D., Benouzza, N., Boudinar, A. H., & Koura, M. B. (2020) · Journal of Power Electronics · doi:10.1007/s43236-020-00169-6 · Cited by 21
“Most studies in the diagnostic field [3, 12, 23, 24] use the FT modulus |X(f)| for classical PSD estimation, which makes us lose useful information.”
BackgroundMethodBearing fault detection in synchronous machine based on the statistical analysis of stator current
Picot, A., Obeid, Z., Regnier, J., Maussion, P., Poignant, S., & Darnis, O. (2012) · IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2012.6389275 · Cited by 18
“However, a few work deals with bearing fault detection in permanent magnet machines ([10], [11]).”
BackgroundNavarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
“In [86,87], the proposed method shows poor sensitivity when the speed is reduced or torque variations occur.”
MethodResultObeid, Z., Picot, A., Poignant, S., Régnier, J., Darnis, O., & Maussion, P. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6389269 · Cited by 17
On-line detection of rotor eccentricity for PMSMs based on hall-effect field sensor measurements
Park, Y., Fernández, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Reigosa, D., & Briz, F. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096798 · Cited by 16
“Although MCSA has many advantages, the detectability of the fault depends on the winding configuration [1], and a complex timefrequency analysis technique is required for motors operating under nonstationary conditions, where the input frequency or load varies [9]-[10].”
BackgroundRefaat, S. S., Abu‐Rub, H., Saad, M., Aboul-Zahab, E. M., & Iqbal, A. (2013) · International Conference on Power Engineering, Energy and Electrical Drives · doi:10.1109/powereng.2013.6635722 · Cited by 16
“Other techniques include stator current Fast Fourier Transform (FFT) analysis [4], Short-Time Fourier Transform (STFT) analysis [5], Continuous Wavelet Analysis (CWT) [6], Hilbert–Huang Transform (HHT) analysis [7], Wigner-Ville Distribution (WVD) analysis [8].”
MethodRahim, A. A. A., Abdullah, S., Singh, S. S. K., & Nuawi, M. Z. (2020) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-019-1213-1 · Cited by 14
Overview of IoT Security Challenges and Sensors Specifications in PMSM for Elevator Applications
Vlachou, E. I., Vlachou, V. I., Efstathiou, D. E., & Karakatsanis, T. S. (2024) · Machines · doi:10.3390/machines12120839 · Cited by 13
Robust Voltage based Technique for Automatic Off-Line Detection of Static Eccentricity of PMSM
Aggarwal, A., Strangas, E. G., & Agapiou, J. (2019) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2019.8785186 · Cited by 13
Hong, J., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6064103 · Cited by 12
Phase-phase Short Fault Analysis of Permanent Magnet Synchronous Motor in Electric Vehicles
Wang, Z., Yang, J., Cao, C., & Zhong-li, G. (2016) · Energy Procedia · doi:10.1016/j.egypro.2016.06.112 · Cited by 11
Koutrakos, K., & Mitronikas, E. D. (2024) · Applied Sciences · doi:10.3390/app14104318 · Cited by 9
“Different faults may appear during PMSM operation and can be related to the rotor [1], bearings [2], magnets [3], or stator windings [4].”
BackgroundFAULT DETECTION AND IDENTIFICATION IN PERMANENT MAGNET SYNCHRONOUS MACHINES
Haddad, R. Z. (2016) · Michigan State University Libraries · doi:10.25335/m53b1t · Cited by 8
Detection of Shaft Misalignment of a PMSM using Zoom-FFT
Koutrakos, K., & Mitronikas, E. D. (2023) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped54949.2023.10271410 · Cited by 7
Incipient bearing fault detection for three-phase Brushless DC motor drive using ANFIS
Abu‐Rub, H., Ahmed, S. M., Iqbal, A., Toliyat, H. A., & Rahimian, M. M. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063688 · Cited by 7
Hadj, N. B., Krichen, M., & Neji, R. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2011.04353 · Cited by 6
Anchehpoli, S. S. M. (2013) · theses.fr (ABES) · doi:10.70675/076de37fz92f0z4ec0z81bbz140d969ad791 · Cited by 6
Research on stator winding open circuit faults of permanent magnet wind turbine
Li, J., Li, W., Zhang, Z., Li, D., Shen, J., Yang, W., & Wang, P. (2017) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems.2017.8056314 · Cited by 5
“[5] J.”
Multi-Power System Electrical Source Fault Review
Salem, M. H., Mansouri, K., Chauveau, E., Salem, Y. B., & Abdelkrim, M. N. (2024) · Energies · doi:10.3390/en17051187 · Cited by 5
Polat, A., Yılmaz, A., & Ergene, L. T. (2018) · Istanbul University - Journal of Electrical & Electronics Engineering · doi:10.5152/iujeee.2018.1821 · Cited by 5
Park, Y., Yang, C., Lee, S. B., Lee, D.-M., Fernández, D., Reigosa, D., & Briz, F. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557899 · Cited by 5
Techniques used in faults detection of permanent magnet synchronous motor: A review
Ziad, H., Al-Dujaili, A. Q., & Humaidi, A. J. (2024) · AIP conference proceedings · doi:10.1063/5.0236292 · Cited by 3
Detection Study of Static Eccentricity and Demagnetization Faults in IPMSM
Verma, P. K., Misra, H., & Rajpurohit, B. S. (2023) · IEEE IAS Global Conference on Renewable Energy and Hydrogen Technologies (GlobConHT) · doi:10.1109/globconht56829.2023.10087871 · Cited by 3
“Wavelet Transform (WT) describe how the spectrum of a signal changes with time and this is its major advantage [3].”
BackgroundFuzzy Inference Based Open and Short Circuit Fault Detection in PMSM with Magnetic Domain Model
Singh, T. P., & Jaiswal, S. (2023) · International Conference on Electrical, Computer and Communication Technologies (ICECCT) · doi:10.1109/icecct56650.2023.10179624 · Cited by 1
Chaudhuri, S. P., Routray, A., Mukhopadhyay, S., & Uttarkabat, S. (2023) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon51785.2023.10312334 · Cited by 1
“…race bearing faults, it has been observed that the stator current is influenced by slight variations in the air gap due to eccentricity, as well as by an increase in instantaneous torque oscillation resulting from fault impacts at the frequency of the inner race fault (fir) [1], [2], [18]–[20].”
BackgroundAffect on Permanent Magnet Synchronous Machine Parameters with Asymmetrical Power Voltage
Zhang, Z., Ma, H., Huang, J., & Qiu, H.-Y. (2015) · Chemical engineering transactions · doi:10.3303/cet1546173
Thapa, K. B. (2023) · Scholarship at UWindsor (University of Windsor)
Metadata
- Authors
- Rosero, J., Romeral, J. L., Cusido, J., Ortega, J. A., & Garcia, A.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Ortega, J. A.
- Venue
- 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition
- Publisher
- IEEE
- Published
- 2008-02
- Pages
- 111-116
- ISSN
- 1048-2334 (ISSN-L)
- OpenAlex
- W2111065160
- Cited by
- 44
- References
- 25
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 5 · 2022: 2 · 2020: 6 · 2019: 5 · 2018: 3 · 2017: 3 · 2016: 3 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 3
- FWCI
- 1.70
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, fault detection, rotor eccentricity, bearing damage, discrete wavelet transform, current harmonics, mechanical fault diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.