The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Building the Ninapro database: A resource for the biorobotics community
Open accessAbstract
This paper is about (self-powered) advanced hand prosthetics and their control via surface electromyography (sEMG). We hereby introduce to the biorobotics community the first version of the Ninapro database, containing kinematic and sEMG data from the upper limbs of 27 intact subjects while performing 52 finger, hand and wrist movements of interest. The setup and experimental protocol are distilled from existing literature and thoroughly described; the data are then analysed and the results are discussed. In particular, it is clear that standard analysis techniques are no longer enough when so many subjects and movements are taken into account. The database is publicly available to download in standard ASCII format. The database is an ongoing work lasting several years, which is planned to contain data from more than 100 intact subjects and 50 trans-radial amputees; characteristics of the amputations, phantom limbs and prosthesis usage will be stored. We therefore hope that it will constitute a standard, widely accepted benchmark for all novel myoelectric hand prosthesis control methods, as well as a fundamental tool to deliver insight into the needs of trans-radial amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pascal visual object classes (VOC) challenge
Everingham, M., Van Gool, L., Williams, C. K. I., Winn, J., & Zisserman, A. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0275-4 · Cited by 19,599
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
Least Squares Support Vector Machines
Suykens, J. A. K., Van Gestel, T., De Brabanter, J., De Moor, B., & Vandewalle, J. (2002) · WORLD SCIENTIFIC eBooks · doi:10.1142/5089 · Cited by 3,642
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
The PASCAL visual object classes challenge 2006 (VOC2006) results
Everingham, M., Zisserman, A., Williams, C. K. I., & Gool, L. V. (2006) · Cited by 2,223
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Least Squares Support Vector Machines
Suykens, J. A. K., Gestel, T. V., Brabanter, J. D., Moor, B. D., & Vandewalle, J. P. L. (2002) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789812776655 · Cited by 1,166
Benchmarking Least Squares Support Vector Machine Classifiers
van Gestel, T., Suykens, J. A. K., Baesens, B., Viaene, S., Vanthienen, J., Dedene, G., de Moor, B., & Vandewalle, J. (2004) · Machine Learning · doi:10.1023/b:mach.0000008082.80494.e0 · Cited by 745
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
A human-assisting manipulator teleoperated by EMG signals and arm motions
Fukuda, O., Tsuji, T., Kaneko, M., & Otsuka, A. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.808873 · Cited by 483
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
Self-citationControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Merletti, R., Botter, A., Troiano, A., Merlo, E., & Minetto, M. A. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.08.006 · Cited by 345
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
EMG-Based Control of a Robot Arm Using Low-Dimensional Embeddings
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2039378 · Cited by 267
Nielsen, J. L. G., Holmgaard, S., Jiang, N., Englehart, K. B., Farina, D., & Parker, P. A. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068298 · Cited by 260
Patterns of Static Prehension in Normal Hands
Kamakura, N., Matsuo, M., Ishii, H., Mitsuboshi, F., & Miura, Y. (1980) · The American Journal of Occupational Therapy · doi:10.5014/ajot.34.7.437 · Cited by 249
Learning EMG control of a robotic hand: towards active prostheses
Bitzer, S., & van der Smagt, P. (2006) · Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006. · doi:10.1109/robot.2006.1642128 · Cited by 245
Self-citationOnline Myoelectric Control of a Dexterous Hand Prosthesis by Transradial Amputees
Cipriani, C., Antfolk, C., Controzzi, M., Lundborg, G., Rosen, B., Carrozza, M. C., & Sebelius, F. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2108667 · Cited by 233
An EMG-Based Robot Control Scheme Robust to Time-Varying EMG Signal Features
Artemiadis, P. K., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040832 · Cited by 224
Leave-One-Out Cross-Validation Based Model Selection Criteria for Weighted LS-SVMs
Cawley, G. C. (2006) · The 2006 IEEE International Joint Conference on Neural Network Proceedings · doi:10.1109/ijcnn.2006.1716307 · Cited by 210
Advances in Surface EMG: Recent Progress in Detection and Processing Techniques
Merletti, R., Aventaggiato, M., Botter, A., Holobar, A., Marateb, H., & Vieira, T. M. M. (2010) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v38.i4.10 · Cited by 176
Fine detection of grasp force and posture by amputees via surface electromyography
Castellini, C., Gruppioni, E., Davalli, A., & Sandini, G. (2009) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2009.08.008 · Cited by 160
Self-citationFarrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159
Multi-subject/daily-life activity EMG-based control of mechanical hands
Castellini, C., Fiorilla, A. E., & Sandini, G. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-41 · Cited by 155
Self-citationA Switching Regime Model for the EMG-Based Control of a Robot Arm
Artemiadis, P., & Kyriakopoulos, K. J. (2010) · IEEE Transactions on Systems Man and Cybernetics Part B (Cybernetics) · doi:10.1109/tsmcb.2010.2045120 · Cited by 145
Overview of the CLEF 2009 Medical Image Retrieval Track
Müller, H., Kalpathy–Cramer, J., Eggel, I., Bedrick, S. D., Radhouani, S., Bakke, B., Kahn, C. E., & Hersh, W. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15751-6_8 · Cited by 139
Sebelius, F., Rosén, B., & Lundborg, G. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2005.01.002 · Cited by 117
Real-time classification of electromyographic signals for robotic control
Crawford, B., Miller, K. J., Shenoy, P., & Rao, R. P. N. (2005) · Cited by 115
EMG-based teleoperation and manipulation with the DLR LWR-III
Vogel, J., Castellini, C., & van der Smagt, P. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6094739 · Cited by 112
Self-citationHybrid Force–Velocity Sliding Mode Control of a Prosthetic Hand
Engeberg, E. D., Meek, S. G., & Minor, M. A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.914672 · Cited by 76
Myocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
Developmental and Functional Hand Grasps
Edwards, S. J., Buckland, D. J., & McCoy-Powlen, J. D. (2002) · Medical Entomology and Zoology · Cited by 66
Improved Grasp Force Sensitivity for Prosthetic Hands Through Force-Derivative Feedback
Engeberg, E. D., & Meek, S. G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912675 · Cited by 47
Tsuji, T., Ichinobe, H., Ito, K., & Nagamachi, M. (1993) · Transactions of the Society of Instrument and Control Engineers · doi:10.9746/sicetr1965.29.1213 · Cited by 44
The wartenweiler memorial lecture the use of surface electromyography in biomechanics
Luca, C. J. D. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)91124-x · Cited by 39
Competitive learning method for robust EMG-to-motion classifier
Kato, R., Yokoi, H., & Arai, T. (2006) · International Conference on Intelligent Autonomous Systems · Cited by 20
Cited by
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680
Zhai, X., Jelfs, B., Chan, R. H. M., & Tin, C. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00379 · Cited by 357
Characterization of a Benchmark Database for Myoelectric Movement Classification
Atzori, M., Gijsberts, A., Kuzborskij, I., Elsig, S., Mittaz Hager, A.-G., Deriaz, O., Castellini, C., Muller, H., & Caputo, B. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328495 · Cited by 293
Self-citationDeep learning based multimodal biomedical data fusion: an overview and comparative review
Duan, J., Xiong, J., Li, Y., & Ding, W. (2024) · Information Fusion · doi:10.1016/j.inffus.2024.102536 · Cited by 284
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
Metadata
- Authors
- Atzori, M., Gijsberts, A., Heynen, S., Hager, A.-G. M., Deriaz, O., van der Smagt, P., Castellini, C., Caputo, B., & Muller, H.
- Venue
- 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob)
- Publisher
- IEEE
- Published
- 2012-06
- Pages
- 1258-1265
- ISSN
- 2155-1774 (ISSN-L)
- OpenAlex
- W2041345816
- Cited by
- 262
- References
- 40
- FWCI
- 19.28
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.