3-D silicon probe array with hybrid polymer interconnect for chronic cortical recording
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The desire to perform chronic recordings from many channels in cortex is high among both neuroscientists and neural prosthesis researchers. The Michigan probe with integrated silicon ribbon cable has been used successfully for obtaining chronic cortical recordings in rodents. As these silicon devices are applied in larger animals and potentially in humans, however, a more mechanically robust, scalable system is required. Here we present a device that takes advantage of several existing, well-characterized technologies and methods and combines them to form a hybrid cortical assembly. The components of the assembly include thin-film multichannel silicon probes and polyimide cables that are electrically and mechanically coupled using thermocompression ball bonding. The resulting probe/cable assembly is low profile (<500 microns) and can be combined with other assemblies to form a 3-D array. Sixteen channel 2-D arrays have been implanted into rat motor cortex and have recorded chronic unit activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationA high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citation
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationChronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Self-citationSubbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
Self-citationKipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Self-citationImplantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
NeuroMEMS: Neural Probe Microtechnologies
HajjHassan, M., Chodavarapu, V., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 190
Metadata
- Authors
- Hetke, J. F., Williams, J. C., Pellinen, D. S., Vetter, R. J., & Kipke, D. R.
- Venue
- First International IEEE EMBS Conference on Neural Engineering, 2003. Conference Proceedings.
- Publisher
- IEEE
- Published
- 2003-12-22
- Pages
- 181-184
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2105097581
- Cited by
- 39
- References
- 3
- FWCI
- 21.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.