CoChat

Fabrication of multi-layer, high-density micro-electrode arrays for neural stimulation and bio-signal recording

Suaning, G.J., Schuettler, M., Ordonez, J.S., Lovell, N.H. · 2007 · 2007 3rd International IEEE/EMBS Conference on Neural Engineering
Cited by 34

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The electrode-tissue interface is of principal importance in neuroprosthesis. Indeed the successes of the cochlear implant and other therapeutic devices are directly attributable to the design and fabrication techniques of their interfaces with neural tissue, that is, the electrode or electrode array. Traditional fabrication techniques are often labor-intensive and do not lend themselves to automation thereby increasing the cost of the electrode, and owing to fabrication variability, potentially compromising the reliability of the devices incorporating them. Exacerbating the difficulties in electrode fabrication further is the fact that only a handful of materials have been demonstrated to be biologically inert. These same materials are often among the most difficult to utilize in the fabrication of neural electrodes. In the present paper, a new methodology for automated fabrication of high-density electrode arrays is presented. Using exclusively biologically-inert raw materials, laser machining techniques combined with multiple layer structuring is shown to achieve feature sizes of the order of 25 mum. As an illustrative example, a 98 electrode array for interfacing with surviving retinal tissue through a visual prosthesis for the blind is presented. Overall dimensions of the array are of the order of 8.7 times 9.4 mm, consistent with approximately 25 degrees of visual field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/cne.2007.369597

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 34

Metadata

Authors
Suaning, G. J., Schuettler, M., Ordonez, J. S., & Lovell, N. H.
Venue
2007 3rd International IEEE/EMBS Conference on Neural Engineering
Publisher
IEEE
Published
2007-05
Pages
5-8
ISSN
1948-3554 (ISSN-L)
OpenAlex
W2134528703
Cited by
34
References
1
FWCI
9.09
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fabrication of multi-layer, high-density micro-electrode arrays for neural stimulation and bio-signal recording. https://app.cochat.ai/papers/10.1109/cne.2007.369597
The paper
Suaning, G. J., Schuettler, M., Ordonez, J. S., & Lovell, N. H. (2007). Fabrication of multi-layer, high-density micro-electrode arrays for neural stimulation and bio-signal recording. 2007 3rd International IEEE/EMBS Conference on Neural Engineering. https://doi.org/10.1109/cne.2007.369597

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.