Magnets faults characterization for Permanent Magnet Synchronous Motors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Nowadays Permanent Magnet Synchronous Motor (PMSM) are an attractive alternative to induction machines for a variety of applications due to their higher efficiency, power density and wide constant power speed range. In this context the condition monitoring of magnets status is receiving more and more attention since is critical for industrial applications. This paper presents a characterization of rotor faults for such a motor due to local and uniform demagnetization by means of two dimensional (2-D) Finite Element Analysis (FEA) and proposes a new non-invasive method for their detection by means of a Fourier transform of the back-EMF. The proposed approach is then validated for three permanent magnet synchronous motors with different winding configurations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Research works printed but not linked: 8
- 10.1109/TPEL.2006.886620 · DOI · Paper page
- 10.1109/7.543863 · DOI · Paper page
- haylock, 2006, Predicting and preventing demagnetization in permanent magnet motor drives, Proc of Power Electronics Machines and Drives 2006, 474
- 10.1109/DEMPED.2007.4393082 · doi:10.1109/demped.2007.4393082
- 10.1109/TIA.2006.882613 · DOI · Paper page
- 10.1109/ISIE.2008.4677217 · DOI · Paper page
- 10.1109/ACEMP.2007.4510542 · doi:10.1109/acemp.2007.4510542
- 10.1109/TMAG.2008.921951 · DOI · Paper page
Cited by
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“14 VOLUME XX, 2017 [94]-[96] BEMF FFT PDF, NINV, AOF SC, OFF, MS”
MethodEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
“Demagnetization of PM motors can be detected by measuring back EMF magnitude [93]–[95] and harmonics”
BackgroundUrresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
“Similar results are obtained when dealing with other types of symmetric windings [13].”
BackgroundMethodResultInfluentialA Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151
“However, analogous results may be obtained when dealing with other stator configurations [14].”
BackgroundResultMoosavi, S. S., Djerdir, A., Amirat, Y. A., & Khaburi, D. A. (2015) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2015.04.062 · Cited by 96
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2013.2247046 · Cited by 73
“However, fractional-slot nonoverlapping windings have a slightly lower winding factor and a high harmonic content in the air-gap magnetomotive distribution [27], [31].”
BackgroundNovel Diagnostic Techniques for Rotating Electrical Machines—A Review
Frosini, L. (2020) · Energies · doi:10.3390/en13195066 · Cited by 67
“Some research revealed that partial demagnetization produces harmonic components in the stator currents at the following frequencies [84,86,87]:”
BackgroundChange‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34
“The most common methods reported in the literature are: current-based techniques [8-16], electromotive force- or voltage-based techniques [17-21], power-based techniques [22] and parameter estimation [23, 24].”
BackgroundMethodKarami, M., Mariun, N., Rezazadeh Mehrjou, M., Ab Kadir, M. Z. A., Misron, N., & Mohd Radzi, M. A. (2014) · Mathematical Problems in Engineering · doi:10.1155/2014/132647 · Cited by 31
Detection of magnet demagnetization in five-phase surface-mounted permanent magnet generators
Casadei, D., Filippetti, F., Mengoni, M., Gritli, Y., Serra, G., Tani, A., & Zarri, L. (2012) · 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254099 · Cited by 22
Self-citation
Metadata
- Authors
- Casadei, D., Filippetti, F., Rossi, C., & Stefani, A.
- Venue
- 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives
- Publisher
- IEEE
- Published
- 2009-08
- Pages
- 1-6
- OpenAlex
- W2077165433
- Cited by
- 74
- References
- 1
- FWCI
- 8.16
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.