Design of CRM AC/DC converter for very high-frequency high-density WBG-based 6.6kW bidirectional on-board battery charger
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The wide-band-gap (WBG) devices based 6.6 kW bidirectional on-board charger (OBC) system for plug-in electric vehicles (PEVs) is recently developed. With the proposed novel variable DC-link voltage system architecture, high frequency soft switching operation, and integrated magnetics, the OBC system becomes more compact and more efficient compared to a Si-based counterpart. The design considerations of the AC/DC stage are introduced in this paper including the evaluation of 1.2 kV SiC MOSFETs; the zero-voltage-switching (ZVS) extension function for the line-cycle ZVS operation; and the novel universal control strategy for both the rectifier mode and the inverter mode. The prototype of the AC/DC stage is built which achieves 98.5% efficiency at higher than 300 kHz switching frequency. Finally, the complete 6.6 kW OBC system using both SiC and GaN devices is demonstrated with 37 W/in3power density and above 96% efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yilmaz, M., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2212917 · Cited by 3,118 · cited 1×
“The state-of-the-art level-2 OBC products are majorly Si-based design, which operates at less than 100 kHz switching frequency, and has only 3~12 W/in3 power density and at most 92~94% efficiency [1, 2].”
Background
Cited by
A Review of Bidirectional On-Board Chargers for Electric Vehicles
Yuan, J., Dorn-Gomba, L., Callegaro, A. D., Reimers, J., & Emadi, A. (2021) · IEEE Access · doi:10.1109/access.2021.3069448 · Cited by 390
“Indeed, bidirectional OBCs are able to achieve vehicle-to-grid (V2G) functionality by returning electrical energy back to the grid, which could be helpful during peak power demands [12], [13].”
BackgroundBidirectional Onboard Chargers for Electric Vehicles: State-of-the-Art and Future Trends
Wouters, H., & Martinez, W. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3319996 · Cited by 280
A High-Efficiency High-Density Wide-Bandgap Device-Based Bidirectional On-Board Charger
Li, B., Li, Q., Lee, F. C., Liu, Z., & Yang, Y. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2845846 · Cited by 259
“Details of this loop and the operation of the ac/dc stage can be found in [25].”
BackgroundSelf-citationHigh-Efficiency High-Density Critical Mode Rectifier/Inverter for WBG-Device-Based On-Board Charger
Liu, Z., Li, B., Lee, F. C., & Li, Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2716873 · Cited by 221
Li, B., Li, Q., & Lee, F. C. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2874806 · Cited by 211
Self-citationA Critical Review on Charging Technologies of Electric Vehicles
Shahjalal, M., Shams, T., Tasnim, M. N., Ahmed, M. R., Ahsan, M., & Haider, J. (2022) · Energies · doi:10.3390/en15218239 · Cited by 66
Liu, B., Qiu, M., Jing, L., & Chen, M. (2017) · 2017 IEEE Transportation Electrification Conference and Expo, Asia-Pacific (ITEC Asia-Pacific) · doi:10.1109/itec-ap.2017.8080766 · Cited by 7
Metadata
- Authors
- Liu, Z., Li, B., Lee, F. C., & Li, Q.
- Venue
- 2016 IEEE Energy Conversion Congress and Exposition (ECCE)
- Publisher
- IEEE
- Published
- 2016-09
- Pages
- 1-8
- OpenAlex
- W2587936572
- Cited by
- 65
- References
- 1
- FWCI
- 10.36
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.