Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography

Han, Hyonyoung, Kim, Min-Joon, Kim, Jung·2007·2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society

Abstract

This paper presents a motion artifact reduction algorithm for a real-time, wireless and wearable photoplethysmography (PPG) device for measuring heart beats. A wearable finger band PPG device consists of a 3-axis accelerometer, infrared LED, photo diode, a microprocessor and wireless module. Sources of the motion artifacts were investigated from the hand motions, through computing the correlations between the three directional finger motions and distorted PPG signals. A two-dimensional active noise cancellation algorithm was applied to compensate the distorted signals by motions, using the directional accelerometer data. NLMS (Normalized Least Mean Square) adaptive filter (4th order) was employed in the algorithm. As a result, the signals' distortion rates were reduced from 52.34% to 3.53%, at frequencies between 1 and 2.5 Hz, which representing daily motions such walking and jogging. The wearable health monitoring device equipped with the motion artifact reduction algorithm can be integrated as a terminal in a so-called ubiquitous healthcare system, which provides a continuous health monitoring without interrupting a daily life.

Integrity signals

Registry

Crossref · 10.1109/iembs.2007.4352596

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.

    “As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Han, H., Kim, M.-J., & Kim, J.
Affiliations
Korea Advanced Institute of Science and Technology (KR)
Venue
2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2007-08
Volume
2007
Pages
1538-1541
ISSN
1557-170X (ISSN-L)
OpenAlex
W2111481778
Cited by
101
References
10
Citations by year
2025: 1 · 2024: 2 · 2023: 3 · 2022: 5 · 2021: 7 · 2020: 9 · 2019: 12 · 2018: 9 · 2017: 11 · 2016: 6 · 2015: 8 · 2014: 7 · 2013: 3 · 2012: 3
FWCI
8.42
Type
conference paper
Language
en
Open access
closed
Locations
  • Conference proceedings (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
photoplethysmography, motion artifact reduction, wearable sensors, accelerometer, active noise control, real-time signal processing, heart rate monitoring, wireless health monitoring, ubiquitous healthcare, walking and jogging
MeSH terms
Algorithms, Diagnosis, Computer-Assisted, Heart Rate, Humans, Motion, Sensitivity and Specificity, Reproducibility of Results, Artifacts, Photoplethysmography, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review