Online Vce measurement method for wear-out monitoring of high power IGBT modules
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A simple Vce online monitoring circuit is presented in this paper. It allows an accurate wear out prediction of IGBT modules, in high-power applications, during normal converter operation. Bipolar measurement allows monitoring of both IGBT and antiparallel diode. The circuit uses two serial connected diodes to sense the Vce voltage with millivolt accuracy. One diode acts as a protection to block high DC voltage present on input terminals. When the device is conducting the voltage on the second diode is measured to compensate for the voltage drop on the protection diode thus eliminating voltage offset due to diodes' forward voltage temperature dependency. Using four diodes one can monitor voltages on all power devices in a converter leg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039
Cited by
A Digital Twin Based Estimation Method for Health Indicators of DC–DC Converters
Peng, Y., Zhao, S., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009600 · Cited by 305
Advanced Accelerated Power Cycling Test for Reliability Investigation of Power Device Modules
Choi, U.-M., Joergensen, S., & Blaabjerg, F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2521899 · Cited by 200
Real-Time Measurement of Temperature Sensitive Electrical Parameters in SiC Power MOSFETs
Griffo, A., Wang, J., Colombage, K., & Kamel, T. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2739687 · Cited by 175
Investigation on Degradation of SiC MOSFET Under Accelerated Stress in a PFC Converter
Jiang, X., Wang, J., Chen, J., Yu, H., Li, Z., & John Shen, Z. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2988447 · Cited by 39
A Simple Plug-In Circuit for IGBT Gate Drivers to Monitor Device Aging: Toward Smart Gate Drivers
Ali, S. H., Li, X., Kamath, A. S., & Akin, B. (2018) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2018.2849653 · Cited by 36
Metadata
- Authors
- Beczkowski, S., Ghimre, P., de Vega, A. R., Munk-Nielsen, S., Rannestad, B., & Thogersen, P.
- Venue
- 2013 15th European Conference on Power Electronics and Applications (EPE)
- Publisher
- IEEE
- Published
- 2013-09
- Pages
- 1-7
- OpenAlex
- W1994170202
- Cited by
- 170
- References
- 1
- FWCI
- 10.58
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online Vce measurement method for wear-out monitoring of high power IGBT modules. https://app.cochat.ai/papers/10.1109/epe.2013.6634390
- The paper
- Beczkowski, S., Ghimre, P., de Vega, A. R., Munk-Nielsen, S., Rannestad, B., & Thogersen, P. (2013). Online Vce measurement method for wear-out monitoring of high power IGBT modules. 2013 15th European Conference on Power Electronics and Applications (EPE). https://doi.org/10.1109/epe.2013.6634390
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.