Online Vce measurement method for wear-out monitoring of high power IGBT modules
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A simple Vce online monitoring circuit is presented in this paper. It allows an accurate wear out prediction of IGBT modules, in high-power applications, during normal converter operation. Bipolar measurement allows monitoring of both IGBT and antiparallel diode. The circuit uses two serial connected diodes to sense the Vce voltage with millivolt accuracy. One diode acts as a protection to block high DC voltage present on input terminals. When the device is conducting the voltage on the second diode is measured to compensate for the voltage drop on the protection diode thus eliminating voltage offset due to diodes' forward voltage temperature dependency. Using four diodes one can monitor voltages on all power devices in a converter leg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019
Selected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
On-line estimation of IGBT junction temperature using on-state voltage drop
Kim, Y.-S., & Sul, S. (1998) · Conference record · doi:10.1109/ias.1998.730245 · Cited by 117 · cited 1×
“A step in Vf1 after 610k cycles was caused by setup maintenance.”
BackgroundLifetime investigation of high power IGBT modules
Due, J., Munk‐Nielsen, S., & Nielsen, R. G. (2011) · VBN Forskningsportal (Aalborg Universitet) · Cited by 76
Self-citationOn-line Junction Temperature Measurement of CoolMOS Devices
Koenig, A., Plum, T., Fidler, P., & De Doncker, R. W. (2007) · 2007 7th International Conference on Power Electronics and Drive Systems · doi:10.1109/peds.2007.4487683 · Cited by 64 · cited 1×
“A step in Vf1 after 610k cycles was caused by setup maintenance.”
BackgroundBond wire lift-off in IGBT modules due to thermomechanical induced stress
Pedersen, K. B., & Pedersen, K. (2012) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254052 · Cited by 50
Innovative measuring system for wear-out indication of high power IGBT modules
Nielsen, R. G., Due, J., & Munk‐Nielsen, S. (2011) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2011.6064000 · Cited by 46 · cited 1×
“High power IGBT modules are the weakest part of the power converter due to continuous exposition to temperature cycles predominantly created by the conduction power losses in the chip [1].”
BackgroundSelf-citation
Cited by
A Digital Twin Based Estimation Method for Health Indicators of DC–DC Converters
Peng, Y., Zhao, S., & Wang, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3009600 · Cited by 305
Choi, U.-M., Blaabjerg, F., & Jorgensen, S. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2690500 · Cited by 248
“Online Measurement circuit with double diodes [68], [69] - Relatively simple circuit.”
BackgroundMethodInfluentialAdvanced Accelerated Power Cycling Test for Reliability Investigation of Power Device Modules
Choi, U.-M., Joergensen, S., & Blaabjerg, F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2521899 · Cited by 200
Real-Time Measurement of Temperature Sensitive Electrical Parameters in SiC Power MOSFETs
Griffo, A., Wang, J., Colombage, K., & Kamel, T. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2739687 · Cited by 175
Investigation on Degradation of SiC MOSFET Under Accelerated Stress in a PFC Converter
Jiang, X., Wang, J., Chen, J., Yu, H., Li, Z., & John Shen, Z. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2988447 · Cited by 39
Metadata
- Authors
- Beczkowski, S., Ghimre, P., de Vega, A. R., Munk-Nielsen, S., Rannestad, B., & Thogersen, P.
- Venue
- 2013 15th European Conference on Power Electronics and Applications (EPE)
- Publisher
- IEEE
- Published
- 2013-09
- Pages
- 1-7
- OpenAlex
- W1994170202
- Cited by
- 170
- References
- 8
- FWCI
- 10.58
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.