The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
False data injection attacks with incomplete information against smart power grids
Abstract
False data injection attacks have recently been introduced as an important class of cyber attacks against smart grid's wide area measurement and monitoring systems. These attacks aim to compromise the readings of multiple power grid sensors and phasor measurement units in order to mislead the operation and control centers. Recent studies have shown that if an adversary has complete knowledge on the power grid topology and transmission-line admittance values, he can adjust the false data injection attack vector such that the attack remains undetected and successfully passes the residue-based bad data detection tests that are commonly used in power system state estimation. However, in this paper, we explain that a realistic false data injection attack is essentially an attack with incomplete information due to the attackers lack of real-time knowledge with respect to various grid parameters and attributes such as the position of circuit breaker switches and transformer tap changers and also because of the attacker's limited physical access to most grid facilities. We mathematically characterize false data injection attacks with incomplete information from both the attacker's and grid operator's viewpoints. Furthermore, we introduce a novel vulnerability measure that can compare and rank different power grid topologies against such attacks. To the best of our knowledge, this paper is the first study to investigate false data injection attacks with line admittance uncertainty.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974
Ipakchi, A., & Albuyeh, F. (2009) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.931384 · Cited by 1,644
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285
State Estimation in Electric Power Systems
Monticelli, A. (1999) · Springer eBooks · doi:10.1007/978-1-4615-4999-4 · Cited by 713
Detecting False Data Injection Attacks on DC State Estimation
Bobba, R. B., Rogers, K. M., Wang, Q., Khurana, H., Nahrstedt, K., & Overbye, T. J. (2010) · Cited by 448
False Data Injection Attacks in Electricity Markets
Xie, L., Mo, Y., & Sinopoli, B. (2010) · 2010 First IEEE International Conference on Smart Grid Communications · doi:10.1109/smartgrid.2010.5622048 · Cited by 384
Towards a Framework for Cyber Attack Impact Analysis of the Electric Smart Grid
Kundur, D., Feng, X., Liu, S., Zourntos, T., & Butler-Purry, K. L. (2010) · 2010 First IEEE International Conference on Smart Grid Communications · doi:10.1109/smartgrid.2010.5622049 · Cited by 185
Limiting false data attacks on power system state estimation
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2010) · Conference on Information Sciences and Systems · doi:10.1109/ciss.2010.5464816 · Cited by 167
Defending false data injection attack on smart grid network using adaptive CUSUM test
Huang, Y., Li, H., Campbell, K. A., & Han, Z. (2011) · Conference on Information Sciences and Systems · doi:10.1109/ciss.2011.5766111 · Cited by 122
Stochastic Optimization Methods
Marti, K. (2008) · Springer eBooks · doi:10.1007/978-3-662-46214-0 · Cited by 119
Cited by
The 2015 Ukraine Blackout: Implications for False Data Injection Attacks
Liang, G., Weller, S. R., Zhao, J., Luo, F., & Dong, Z. Y. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2631891 · Cited by 1,248
A Review of False Data Injection Attacks Against Modern Power Systems
Liang, G., Zhao, J., Luo, F., Weller, S. R., & Dong, Z. Y. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2495133 · Cited by 1,028
Survey in Smart Grid and Smart Home Security: Issues, Challenges and Countermeasures
Komninos, N., Philippou, E., & Pitsillides, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2014.2320093 · Cited by 560
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
Zografopoulos, I., Ospina, J., Liu, X., & Konstantinou, C. (2021) · IEEE Access · doi:10.1109/access.2021.3058403 · Cited by 314
Blind False Data Injection Attack Using PCA Approximation Method in Smart Grid
Yu, Z.-H., & Chin, W.-L. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2382714 · Cited by 305
Securing internet of medical things systems: limitations, issues and recommendations
Yaacoub, J.-P. A., Noura, M., Noura, H. N., Salman, O., Yaacoub, E., Couturier, R., & Chehab, A. (2020) · Future Generation Computer Systems · doi:10.1016/j.future.2019.12.028 · Cited by 308
Safety and Security in Cyber-Physical Systems and Internet-of-Things Systems
Wolf, M., & Serpanos, D. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2781198 · Cited by 250
IoMT amid COVID-19 pandemic: Application, architecture, technology, and security
Mohd Aman, A. H., Hassan, W. H., Sameen, S., Attarbashi, Z. S., Alizadeh, M., & Latiff, L. A. (2021) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2020.102886 · Cited by 237
“Another common type of attack is a SQL injection that opens back doors for cybercriminals to gain access to medical databases (Rahman and Mohsenian-Rad, 2012).”
State of the art of cyber-physical systems security: An automatic control perspective
Zacchia Lun, Y., D’Innocenzo, A., Smarra, F., Malavolta, I., & Di Benedetto, M. D. (2019) · Journal of Systems and Software · doi:10.1016/j.jss.2018.12.006 · Cited by 211
“Attack at physical layer Sajjad et al. (2015); Shoukry et al.”
BackgroundFalse data attack models, impact analyses and defense strategies in the electricity grid
Liu, X., & Li, Z. (2017) · The Electricity Journal · doi:10.1016/j.tej.2017.04.001 · Cited by 57
False Data Injection Impact Analysis In AI-Based Smart Grid
Tufail, S., Batool, S., & Sarwat, A. I. (2021) · SoutheastCon 2021 · doi:10.1109/southeastcon45413.2021.9401940 · Cited by 38
Investigation of False Data Injection Attacks on Smart Inverter Settings
Olowu, T. O., Dharmasena, S., Jafari, H., & Sarwat, A. (2020) · 2020 IEEE CyberPELS (CyberPELS) · doi:10.1109/cyberpels49534.2020.9311541 · Cited by 25
“Another study on FDIs in smart grid can be found in [9] which addresses the situation that the attacker has incomplete information about the admittance of transmission lines.”
BackgroundFalse Data Injection Attacks in Healthcare
Ahmed, M., & Barkat Ullah, A. S. S. M. (2018) · Communications in Computer and Information Science · doi:10.1007/978-981-13-0292-3_12 · Cited by 26
Kumar, A., Das, T. K., & Pandey, R. K. (2024) · Proceedings of the 10th ACM Cyber-Physical System Security Workshop · doi:10.1145/3626205.3659146 · Cited by 4
Metadata
- Authors
- Rahman, M. A., & Mohsenian-Rad, H.
- Venue
- 2012 IEEE Global Communications Conference (GLOBECOM)
- Publisher
- IEEE
- Published
- 2012-12
- Pages
- 3153-3158
- ISSN
- 1930-529X (ISSN-L)
- OpenAlex
- W2064111006
- Cited by
- 313
- References
- 12
- FWCI
- 18.02
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.