Cited by 5Artificial Intelligence in HealthcareCardiomyopathy and Myosin StudiesArtificial Intelligence in Healthcare and Education

HCM-Dynamic-Echo: A Framework for Detecting Hypertrophic Cardiomyopathy (HCM) in Echocardiograms

Almadani, Abdulsalam, Agu, Emmanuel, Sarwar, Atifa, Ahluwalia, Monica, Kpodonu, Jacques·2023·2023 IEEE International Conference on Digital Health (ICDH)

Abstract

Cardiovascular disease (CVD) is the leading cause of death worldwide. Hypertrophic Cardiomyopathy (HCM) is the most common genetic disease in which the heart’s Left Ventricular (LV) wall becomes thicker and stiffer, making it difficult to pump blood. HCM affects 1:200 to 1:500 people and can result in Sudden Cardiac Death (SCD), heart failure, and abnormal heart rhythms leading to stroke. Early diagnosis and treatment of HCM can improve outcomes. An echocardiogram, a heart ultrasound, is routinely performed on patients and is currently the gold standard for HCM diagnosis. However, expert analyses of echocardiograms can be inconsistent, resulting in missed diagnoses. Deep Video Action Recognition (VAR) models have achieved state-of-the-art performance for the task of recognizing human actions, such as running and walking, in a video. In this paper, we innovatively propose HCM-Dynamic-Echo, an end-to-end deep learning framework that uses the SlowFast VAR architecture, for the binary classification of echocardiogram videos as having HCM vs. normal. SlowFast has two arms: arm 1 (slow pathway) analyzes spatial features, while arm 2 (fast pathway) captures temporal structural information to increase video recognition accuracy. Furthermore, we employed transfer learning, pre-training HCM-Dynamic-Echo on the large Stanford EchoNet-Dynamic echocardiogram dataset, enabling HCM detection in a smaller echocardiogram video dataset. In rigorous evaluation, HCM-Dynamic-Echo outperformed state-of-the-art baselines, achieving an accuracy of 93.13%, a F1-score of 92.98%, Positive Predictive Value (PPV) of 94.64%, specificity of 94.87%, and an Area Under the Curve (AUC) of 93.13%. To the best of our knowledge, our work is the first that innovatively utilized the SlowFast VAR architecture for predicting HCM in racially and ethnically diverse echocardiogram videos.

Integrity signals

Registry

Crossref · 10.1109/icdh60066.2023.00039

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • HCM Dynamic Echo achieved an accuracy of 93.13%, an F1 score of 92.98%, a PPV of 94.64%, a specificity of 94.87%, and an AUC of 93.13% for binary classification of echocardiography videos into HCM or normal.

    “In rigorous evaluations, HCM Dynamic Echo outperformed state-of-the-art baselines, with an accuracy of 93.13%, an F1 score of 92.98%, a Positive Predictive Value (PPV) of 94.64%, a specificity of 94.87%, and an Area Under the Curve (AUC) of 93.13%.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Almadani, A., Agu, E., Sarwar, A., Ahluwalia, M., & Kpodonu, J.
Affiliations
  • Worcester Polytechnic Institute (US)
  • Brigham and Women's Hospital (US)
  • Beth Israel Deaconess Medical Center (US)
Venue
2023 IEEE International Conference on Digital Health (ICDH)
Publisher
IEEE
Published
2023-07
Pages
217-226
OpenAlex
W4386215261
Cited by
5
References
24
Citations by year
2025: 1 · 2024: 4
FWCI
1.38
Type
conference paper
Language
en
Open access
closed
Locations
IEEE International Conference on Digital Health (ICDH) (publishedVersion)
Topics
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiomyopathy and Myosin Studies
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
hypertrophic cardiomyopathy, SlowFast, video action recognition, transfer learning, automated diagnosis, left ventricular wall thickening, racial and ethnic diversity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›