Towards Benchmarked Sleep Detection with Wrist-Worn Sensing Units
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The monitoring of sleep by quantifying sleeping time and quality is pivotal in many preventive health care scenarios. A substantial amount of wearable sensing products have been introduced to the market for just this reason, detecting whether the user is either sleeping or awake. Assessing these devices for their accuracy in estimating sleep is a daunting task, as their hardware design tends to be different and many are closed-source systems that have not been clinically tested. In this paper, we present a challenging benchmark dataset from an open source wrist-worn data logger that contains relatively high-frequent (100Hz) 3D inertial data from 42 sleep lab patients, along with their data from clinical polysomnography. We analyse this dataset with two traditional approaches for detecting sleep and wake states and propose a new algorithm specifically for 3D acceleration data, which operates on a principle of Estimation of Stationary Sleep-segments (ESS). Results show that all three methods generally over-estimate for sleep, with our method performing slightly better (almost 79% overall median accuracy) than the traditional activity count-based methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Van Dongen, H. P. A., Maislin, G., Mullington, J. M., & Dinges, D. F. (2003) · Sleep · doi:10.1093/sleep/26.2.117 · Cited by 3,173 · cited 1×
“Sleep is an essential part of our life – almost one third of it we spend sleeping – and has been identified to be crucial to our health for a variety of reasons [1]–[3].”
BackgroundThe Role of Actigraphy in the Study of Sleep and Circadian Rhythms
Ancoli-Israel, S., Cole, R., Alessi, C., Chambers, M., Moorcroft, W., & Pollak, C. P. (2003) · Sleep · doi:10.1093/sleep/26.3.342 · Cited by 2,751 · cited 1×
“Before any of the algorithms are being used, we filter the raw acceleration data to remove any noise present in the raw data, as well as any high-frequency motion artefacts, as argued for in [24].”
MethodKushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Behavioral and Physiological Consequences of Sleep Restriction
Banks, S., & Dinges, D. F. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26918 · Cited by 1,505 · cited 2×
“Sleep is an essential part of our life – almost one third of it we spend sleeping – and has been identified to be crucial to our health for a variety of reasons [1]–[3].”
BackgroundThe role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415
THE FIRST NIGHT EFFECT: AN EEG STUDYOF SLEEP
Agnew, H. W., Webb, W. B., & Williams, R. L. (1966) · Psychophysiology · doi:10.1111/j.1469-8986.1966.tb02650.x · Cited by 1,147 · cited 1×
“Additionally, this method is expensive, time-consuming, and the ”first-night-effect” [8], i.”
MethodMorgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Sleep viewed as a state of adaptive inactivity
Siegel, J. M. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2697 · Cited by 468 · cited 1×
“where A is the total activity count for the scored epoch a0, a−x is the activity count before the scored epoch and a+x the one after, with x ∈ [1, 2] minutes.”
BackgroundMovement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Cited by
A novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744
Willetts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
“For this study we did not use traditional cumbersome methods to collect sleep 34 and energy expenditure 35 groundtruth data, as we preferred to use proxy reference methods for free-living assessment at scale 35,36 .”
MethodA Comprehensive Study of Activity Recognition Using Accelerometers
Twomey, N., Diethe, T., Fafoutis, X., Elsts, A., McConville, R., Flach, P., & Craddock, I. (2018) · doi:10.20944/preprints201803.0147.v1 · Cited by 143
A Comprehensive Study of Activity Recognition Using Accelerometers
Twomey, N., Diethe, T., Fafoutis, X., Elsts, A., McConville, R., Flach, P., & Craddock, I. (2018) · Informatics · doi:10.3390/informatics5020027 · Cited by 143
Objective assessment of depressive symptoms with machine learning and wearable sensors data
Ghandeharioun, A., Fedor, S., Sangermano, L., Ionescu, D., Alpert, J., Dale, C., Sontag, D., & Picard, R. (2017) · 2017 Seventh International Conference on Affective Computing and Intelligent Interaction (ACII) · doi:10.1109/acii.2017.8273620 · Cited by 116
Metadata
- Authors
- Borazio, M., Berlin, E., Kucukyildiz, N., Scholl, P., & Van Laerhoven, K.
- Venue
- 2014 IEEE International Conference on Healthcare Informatics
- Publisher
- IEEE
- Published
- 2014-09
- Pages
- 125-134
- OpenAlex
- W2064657839
- Cited by
- 50
- References
- 9
- FWCI
- 1.44
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards Benchmarked Sleep Detection with Wrist-Worn Sensing Units. https://app.cochat.ai/papers/10.1109/ichi.2014.24
- The paper
- Borazio, M., Berlin, E., Kucukyildiz, N., Scholl, P., & Van Laerhoven, K. (2014). Towards Benchmarked Sleep Detection with Wrist-Worn Sensing Units. 2014 IEEE International Conference on Healthcare Informatics. https://doi.org/10.1109/ichi.2014.24
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.