Theory, simulation, and compensation of physiological motion artifacts in functional MRI
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Mapping the location of brain activity is a new and exciting application of magnetic resonance imaging (MRI). This application area has already seen the use of a variety of magnetic resonance image acquisition methods, including spin-warp, spiral k-space, and echo-planar imaging, each of which has its own advantages and disadvantages. The authors examine physiological sources of image artifacts for functional brain mapping with MRI. In particular, they examine the nature of respiration-related signal changes in the brain and characterize the response of spin-warp and spiral k-space imaging to this source of artifacts. This characterization uses a model in which the respiration causes an undesired periodic structure in the Fourier domain of the image. The authors present simulation and experimental results to support this model and also present several methods to compensate for these effects so that these imaging methods can be used to generate artifact-free images.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Self‐navigated spiral fMRI: Interleaved versus single‐shot
Glover, G. H., & Lai, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390305 · Cited by 476
Retrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
The role of segmentation in phonological processing: an fMRI investigation
Burton, M. W., Small, S. L., & Blumstein, S. E. (2000) · Journal of Cognitive Neuroscience · doi:10.1162/089892900562309 · Cited by 378
“Functional data were acquired using the spiral k-space method (Noll & Schneider, 1994; Noll, Cohen, Meyer, & Schneider, 1995).”
MethodRespiration‐induced B0fluctuations and their spatial distribution in the human brain at 7 Tesla
Van de Moortele, P., Pfeuffer, J., Glover, G. H., Ugurbil, K., & Hu, X. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10145 · Cited by 240
Lateralization of motor circuits and handedness during finger movements
Solodkin, A., Hlustik, P., Noll, D. C., & Small, S. L. (2001) · European Journal of Neurology · doi:10.1046/j.1468-1331.2001.00242.x · Cited by 209
Self-citation
Metadata
- Authors
- Noll, D. C., & Schneider, W.
- Venue
- Proceedings of 1st International Conference on Image Processing
- Publisher
- IEEE Comput. Soc. Press
- Published
- 2002-12-17
- Volume
- 3
- Pages
- 40-44
- ISSN
- 1522-4880 (ISSN-L)
- OpenAlex
- W2102118299
- Cited by
- 72
- References
- 2
- FWCI
- 6.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Theory, simulation, and compensation of physiological motion artifacts in functional MRI. https://app.cochat.ai/papers/10.1109/icip.1994.413892
- The paper
- Noll, D. C., & Schneider, W. (2002). Theory, simulation, and compensation of physiological motion artifacts in functional MRI. Proceedings of 1st International Conference on Image Processing. https://doi.org/10.1109/icip.1994.413892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.