Computing with a muscular-hydrostat system
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Octopus arms, as well as elephant trunks, squid tentacles, and vertebrate tongues are termed muscular-hydrostats. In such structures, the volume of the organ remains constant during their motions, enabling diverse, complex, and highly controlled movements without the support of a skeleton. Such flexible structures show major advantages over articulated arms that have a rigid skeleton and joints. These advantages have been attracting roboticists aiming to apply these material properties to soft robot controls. In this paper, we show that the muscular-hydrostat system itself has the computational capacity to achieve a complex nonlinear computation. By using a 3D dynamic simulator of the system inspired by the octopus, we actually demonstrate that the system is capable of emulating complex nonlinear dynamical systems by exploiting its elastic body dynamics as a computational resource. In addition, we systematically analyze its computational power in terms of memory capacity, and show that the system has an intrinsic and characteristic short term memory profile. Finally, the implications for soft robot control and future application scenarios are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maass, W., Natschläger, T., & Markram, H. (2002) · Neural Computation · doi:10.1162/089976602760407955 · Cited by 4,025 · cited 1×
“In this paper, we first demonstrate whether the proposed system can achieve a complex computation by assigning benchmark tasks [22], [23], [37], [38], which are often used in the context of recurrent neural network learning [39] or the reservoir computing approach [37], [40], [41].”
MethodHarnessing Nonlinearity: Predicting Chaotic Systems and Saving Energy in Wireless Communication
Jaeger, H., & Haas, H. (2004) · Science · doi:10.1126/science.1091277 · Cited by 3,811 · cited 2×
“In this paper, we first demonstrate whether the proposed system can achieve a complex computation by assigning benchmark tasks [22], [23], [37], [38], which are often used in the context of recurrent neural network learning [39] or the reservoir computing approach [37], [40], [41].”
BackgroundMethodAn experimental unification of reservoir computing methods
Verstraeten, D., Schrauwen, B., D’Haene, M., & Stroobandt, D. (2007) · Neural Networks · doi:10.1016/j.neunet.2007.04.003 · Cited by 1,135
How the Body Shapes the Way We Think: A New View of Intelligence
Pfeifer, R., & Bongard, J. (2006) · doi:10.7551/mitpress/3585.001.0001 · Cited by 956
Self-citationTongues, Tentacles and Trunks: the Biomechanics of Movement in Muscular-Hydrostats
KIER, W. M., & SMITH, K. K. (1985) · Zoological Journal of the Linnean Society · doi:10.1111/j.1096-3642.1985.tb01178.x · Cited by 910
Control of octopus arm extension by a peripheral motor program
Sumbre, G., Gutfreund, Y., Fiorito, G., Flash, T., & Hochner, B. (2001) · Science · doi:10.1126/science.1060976 · Cited by 319
Cited by
Information processing via physical soft body
Nakajima, K., Hauser, H., Li, T., & Pfeifer, R. (2015) · Scientific Reports · doi:10.1038/srep10487 · Cited by 324
Self-citationDesign and control of compliant tensegrity robots through simulation and hardware validation
Caluwaerts, K., Despraz, J., Işçen, A., Sabelhaus, A. P., Bruce, J., Schrauwen, B., & SunSpiral, V. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0520 · Cited by 267
A soft body as a reservoir: case studies in a dynamic model of octopus-inspired soft robotic arm
Nakajima, K., Hauser, H., Kang, R., Guglielmino, E., Caldwell, D. G., & Pfeifer, R. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00091 · Cited by 180
Self-citationExploiting short-term memory in soft body dynamics as a computational resource
Nakajima, K., Li, T., Hauser, H., & Pfeifer, R. (2014) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0437 · Cited by 128
Self-citation
Metadata
- Authors
- Nakajima, K., Hauser, H., Kang, R., Guglielmino, E., Caldwell, D. G., & Pfeifer, R.
- Venue
- 2013 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2013-05
- Pages
- 1504-1511
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2125131463
- Cited by
- 42
- References
- 6
- FWCI
- 4.62
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computing with a muscular-hydrostat system. https://app.cochat.ai/papers/10.1109/icra.2013.6630770
- The paper
- Nakajima, K., Hauser, H., Kang, R., Guglielmino, E., Caldwell, D. G., & Pfeifer, R. (2013). Computing with a muscular-hydrostat system. 2013 IEEE International Conference on Robotics and Automation. https://doi.org/10.1109/icra.2013.6630770
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.