Interfacing regenerating peripheral nerves with a micromachined polyimide sieve electrode
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A design of a flexible, light-weighted sieve electrode with integrated cables for interfacing regenerating nerves has been developed using micromachining technologies. The authors used polyimide as substrate and insulation layers and platinum as electrode metallization. The materials showed no cytotoxic effects in biocompatibility testing. In first chronic experiments on the sciatic nerve of rats, the authors received good regeneration, a functional reinervation, and no mechanical traumatization of the nerve caused by the microsystem due to the flexible materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144
Cited by
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Self-citationLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Self-citationCeballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61
Self-citationRamachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46
Self-citationPrintable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
“Regenerative electrodes can interface stably at chronic timescales, but typically entail significant nerve damage during implant and a prolonged period of compromised function during regrowth (Lacour et al., 2009; Mannard et al., 1974; Stieglitz et al., 1997).”
Background
Metadata
- Authors
- Stieglitz, T., Navarro, X., Calvet, S., Blau, C., & Meyer, J.-U.
- Venue
- Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 1996
- Pages
- 365-366 vol.1
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2541557145
- Cited by
- 20
- References
- 2
- FWCI
- 19.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.