Abstract
This research investigates the feasibility of using the electrocardiogram (ECG) as a new biometric for human identity verification. It is well known that the shapes of the ECG waveforms of different persons are different but it is unclear whether such differences can be used to identify different individuals. In this research, we demonstrated successfully that it is possible to identify a specific person from a group of candidates using a one-lead ECG. A one-lead ECG, unlike two-dimensional biometrics, such as the fingerprint, is a one-dimensional, low-frequency signal that can be recorded from electrodes on the hands. This research applied two techniques, template matching and a decision-based neural network (DBNN), to implement the identity verification. Using each of the two methods separately on a predetermined group of 20 subjects, the experimental results showed that the rate of correct identity verification was 95% for template matching and 80% for the DBNN. Combining the two methods produced a 100% correct rate. Our results show that ECG analysis is a potentially applicable method for human identity verification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ECG analysis: a new approach in human identification
Biel, L., Pettersson, O., Philipson, L., & Wide, P. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.930458 · Cited by 949
An introduction evaluating biometric systems
Phillips, P. J., Martin, A., Wilson, C. L., & Przybocki, M. (2000) · Computer · doi:10.1109/2.820040 · Cited by 391
BiolD: a multimodal biometric identification system
Frischholz, R. W., & Dieckmann, U. (2000) · Computer · doi:10.1109/2.820041 · Cited by 346
Decision-based neural networks with signal/image classification applications
Kung, S. Y., & Taur, J. S. (1995) · IEEE Transactions on Neural Networks · doi:10.1109/72.363439 · Cited by 164
An ECG Classifier Designed Using Modified Decision Based Neural Networks
Simon, B. P., & Eswaran, C. (1997) · Computers and Biomedical Research · doi:10.1006/cbmr.1997.1446 · Cited by 97
Cited by
Unveiling the Biometric Potential of Finger-Based ECG Signals
Lourenço, A., Silva, H., & Fred, A. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/720971 · Cited by 754
Wavelet Distance Measure for Person Identification Using Electrocardiograms
Chan, A. D. C., Hamdy, M. M., Badre, A., & Badee, V. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.909996 · Cited by 363
ECG Biometric Recognition: A Comparative Analysis
Odinaka, I., Lai, P.-H., Kaplan, A. D., O'Sullivan, J. A., Sirevaag, E. J., & Rohrbaugh, J. W. (2012) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2012.2215324 · Cited by 356
Analysis of Human Electrocardiogram for Biometric Recognition
Wang, Y., Agrafioti, F., Hatzinakos, D., & Plataniotis, K. N. (2007) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2008/148658 · Cited by 339
ECG Biometric Recognition Without Fiducial Detection
Plataniotis, K. N., Hatzinakos, D., & Lee, J. K. M. (2006) · 2006 Biometrics Symposium: Special Session on Research at the Biometric Consortium Conference · doi:10.1109/bcc.2006.4341628 · Cited by 243
“Recently, a few proposals [1] [2] [3] [4] suggested the interval interval possibility of a new type of biometric that can be used and RQ amplitude R to P offset possibility ~~~~~~~~~~~~~~~~~~~~~~~~~interval cannot be copied easily: the human heartbeat.”
BackgroundECG Authentication for Mobile Devices
Arteaga-Falconi, J. S., Al Osman, H., & El Saddik, A. (2016) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2503863 · Cited by 200
Evolution, Current Challenges, and Future Possibilities in ECG Biometrics
Ribeiro Pinto, J., Cardoso, J. S., & Lourenco, A. (2018) · IEEE Access · doi:10.1109/access.2018.2849870 · Cited by 195
“[51], using ambulatory recordings from MIT-BIH Normal Sinus Rhythm database (described further on in this survey), acquired for thirty minutes using Holter equipment.”
MethodBao, S.-D., Zhang, Y.-T., & Shen, L.-F. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1616965 · Cited by 172
“HRV is a measure of the beat-to-beat alteration in HR, which is readily available in several kinds of physiological signals related to the cardiovascular system, such as ECG and PPG.”
BackgroundInfluentialA novel feature ranking algorithm for biometric recognition with PPG signals
Reşit Kavsaoğlu, A., Polat, K., & Recep Bozkurt, M. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.03.005 · Cited by 158
“However, a finger print can be characterized with latex, face recognition can be faked with a photograph, voice can be imitated [11], and the EEG and ECG-based methods are impractical as various electrodes are required in order to acquire bio-signals.”
BackgroundECG biometric recognition using SVM‐based approach
Rezgui, D., & Lachiri, Z. (2016) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.22241 · Cited by 40
“[8] were interested in a few fiducial points that surround each QRS complex.”
BackgroundMedical biometrics in mobile health monitoring
Agrafioti, F., Bui, F. M., & Hatzinakos, D. (2011) · Security and Communication Networks · doi:10.1002/sec.227 · Cited by 32
“For the ECG biometric, two categories of feature extraction methodologies can be considered: (a) fiducial based [4,5,7] or (b) fiducial independent [6,11].”
Method
Metadata
- Authors
- Shen, T. W., Tompkins, W. J., & Hu, Y. H.
- Venue
- Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology
- Publisher
- IEEE
- Published
- 2003-06-25
- Volume
- 1
- Pages
- 62-63
- OpenAlex
- W1655694665
- Cited by
- 278
- References
- 5
- FWCI
- 2.54
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.