CoChat

System to Assess Accuracy of Micromanipulation

Latt, W. T., Tan, U. X., Veluvolu, K. C., Lin, J. K. D., Shee, C. Y., Ang, W. T. · 2007 · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Cited by 13

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The authors had previously developed an optical micro motion sensing system (M2S2) using a pair of orthogonally placed position sensitive detectors (PSD) to track 3D displacement of the tip of a microsurgical instrument in real-time. In the M2S2 system, an infrared (IR) diode is used to illuminate the workspace. A ball is attached to the tip of an intraocular shaft to reflect IR rays onto the PSDs. Instrument tip position is then calculated from the centroid position of reflected IR light on the PSDs. The M2S2 system together with a test platform is used as an evaluation system to assess the accuracy and physiological tremor of subjects performing micromanipulation tasks. Since the need to use the ball at the instrument tip prevents the subjects from performing the manipulation tasks precisely, a laser light is provided as a guide for the subjects to aim at the target precisely. A laser diode module is placed inside the instrument to provide the required laser light. The instrument intraocular shaft is replaced with a same-sized hollow tube to let the laser light from the instrument pass through down to the target. The laser light spot position on the platform is used to access the performance of the subjects. The laser light spot position is calculated from the tilt angle information provided by an accelerometer placed inside the instrument, and the instrument tip position information given by M2S2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/iembs.2007.4353651

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 7

  1. 10.1109/IEMBS.2004.1403783 · DOI
  2. 10.1109/IEMBS.2001.1019574 · DOI · Paper page
  3. schenker, 1995, Development of a telemanipulator for dexterity enhanced microsurgery, 2nd Intl Symp Med Robot Comput Assist Surg, 81
  4. 10.1109/IEMBS.2001.1019573 · DOI · Paper page
  5. ang, 2001, Design and implementation of active error canceling in a hand-held microsurgical instrument, Proc IEEE/RSJ Int Conf Intell Robots Syst, 1106
  6. walsh, 1994, physiological finger tremor in medical students and others, Neurol Dis Ther, 30, 63
  7. 10.1109/IEMBS.1997.757046 · DOI · Paper page

Cited by

See all 13

Metadata

Authors
Latt, W. T., Tan, U. X., Veluvolu, K. C., Lin, J. K. D., Shee, C. Y., & Ang, W. T.
Venue
2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Publisher
IEEE
Published
2007-08
Volume
30
Pages
5743-5746
ISSN
1557-170X (ISSN-L)
OpenAlex
W2161520740
Cited by
13
References
6
FWCI
3.63
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: System to Assess Accuracy of Micromanipulation. https://app.cochat.ai/papers/10.1109/iembs.2007.4353651
The paper
Latt, W. T., Tan, U. X., Veluvolu, K. C., Lin, J. K. D., Shee, C. Y., & Ang, W. T. (2007). System to Assess Accuracy of Micromanipulation. 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2007.4353651

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.