A wearable system for the seismocardiogram assessment in daily life conditions
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Seismocardiogram (SCG) is the recording of the minute body accelerations induced by the heart activity, and reflects mechanical aspects of heart contraction and blood ejection. So far, most of the available systems for the SCG assessment are designed to be used in a laboratory or in controlled behavioral and environmental conditions. In this paper we propose a modified version of a textile-based wearable device for the unobtrusive recording of ECG, respiration and accelerometric data (the MagIC system), to assess the 3d sternal SCG in daily life. SCG is characterized by an extremely low magnitude of the accelerations (in the order of g × 10(-3)), and is masked by major body accelerations induced by locomotion. Thus in daily life recordings, SCG can be measured whenever the subject is still. We observed that about 30 seconds of motionless behavior are sufficient for a stable estimate of the average SCG waveform, independently from the subject's posture. Since it is likely that during spontaneous behavior the subject may stay still for at least 30 seconds several times in a day, it is expected that the SCG could be repeatedly estimated and tracked over time through a prolonged data recording. These observations represent the first testing of the system in the assessment of SCG out of a laboratory environment, and open the possibility to perform SCG studies in a wide range of everyday conditions without interfering with the subject's activity tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
“Traditional IMUs can be used continuously but are most effective at low frequencies (0–100 Hz) due mainly to their high inertial mass and loose coupling to the body 9,10 .”
InfluentialDi Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Self-citationDefinition of Fiducial Points in the Normal Seismocardiogram
Sørensen, K., Schmidt, S. E., Jensen, A. S., Søgaard, P., & Struijk, J. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-33675-6 · Cited by 111
Metadata
- Authors
- Di Rienzo, M., Meriggi, P., Rizzo, F., Vaini, E., Faini, A., Merati, G., Parati, G., & Castiglioni, P.
- Venue
- 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Publisher
- IEEE
- Published
- 2011-08
- Volume
- 2011
- Pages
- 4263-4266
- OpenAlex
- W2056663426
- Cited by
- 61
- References
- 1
- FWCI
- 10.85
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A wearable system for the seismocardiogram assessment in daily life conditions. https://app.cochat.ai/papers/10.1109/iembs.2011.6091058
- The paper
- Di Rienzo, M., Meriggi, P., Rizzo, F., Vaini, E., Faini, A., Merati, G., Parati, G., & Castiglioni, P. (2011). A wearable system for the seismocardiogram assessment in daily life conditions. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6091058
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.