Toward a modular soft sensor-embedded glove for human hand motion and tactile pressure measurement
The DOI matches its Crossref record.
Abstract
The ability to measure human hand motions and interaction forces is critical to improving our understanding of manual gesturing and grasp mechanics. This knowledge serves as a basis for developing better tools for human skill training and rehabilitation, exploring more effective methods of designing and controlling robotic hands, and creating more sophisticated human-computer interaction devices which use complex hand motions as control inputs. This paper presents work on the design, fabrication, and experimental validation of a soft sensor-embedded glove which measures both hand motion and contact pressures during human gesturing and manipulation tasks. We design an array of liquid-metal embedded elastomer sensors to measure up to hundreds of Newtons of interaction forces across the human palm during manipulation tasks and to measure skin strains across phalangeal and carpal joints for joint motion tracking. The elastomeric sensors provide the mechanical compliance necessary to accommodate anatomical variations and permit a normal range of hand motion. We explore methods of assembling this soft sensor glove from modular, individually fabricated pressure and strain sensors and develop design guidelines for their mechanical integration. Experimental validation of a soft finger glove prototype demonstrates the sensitivity range of the designed sensors and the mechanical robustness of the proposed assembly method, and provides a basis for the production of a complete soft sensor glove from inexpensive modular sensor components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 28
- mathiowetz, 1985, Grip and pinch strength: Normative data for adults, Archives of Physical Medicine and Rehabilitation, 66, 69
- 10.1109/IROS.2008.4651053 · DOI
- 10.1016/0363-5023(90)90102-W · DOI · Paper page
- 10.1109/JSEN.2012.2200790 · DOI · Paper page
- 10.1109/ICRA.2013.6631337 · DOI
- 10.1109/ICRA.2011.5980082 · DOI · Paper page
- 10.1371/journal.pone.0049365 · DOI · Paper page
- tongrod, 2010, A low-cost data-glove for human computer interaction based on inkjet printed sensors and zigbee networks, IEEE Int Symp on Wearable Computers
- 10.1109/IEMBS.2006.260574 · doi:10.1109/iembs.2006.260574
- pollard, 2002, Tendon arrangement and muscle force requirements force capabilities in a robotic finger, IEEE Int Conf of Robotics and Automation, 3755
- 10.1002/jor.1100030210 · DOI · Paper page
- 10.1136/jnnp.43.10.925 · doi:10.1136/jnnp.43.10.925
- 10.4067/S0717-95022010000300015 · DOI · Paper page
- 10.1088/0960-1317/20/12/125029 · DOI · Paper page
- 10.1109/JSEN.2013.2297380 · doi:10.1109/jsen.2013.2297380
- 10.1109/ICRA.2012.6225071 · DOI
- 10.1109/BIOROB.2006.1639182 · doi:10.1109/biorob.2006.1639182
- 10.1145/212430.212431 · DOI · Paper page
- 10.4108/icst.pervasivehealth.2011.246010 · doi:10.4108/icst.pervasivehealth.2011.246010
- 10.1109/IWASI.2011.6004715 · doi:10.1109/iwasi.2011.6004715
- 10.1109/ISWC.2001.962130 · doi:10.1109/iswc.2001.962130
- bowman, 2001, Using pinch gloves(TM) for both natural and abstract interaction techniques in virtual environments, Tech Report TR-01-23
- 10.1145/1242073.1242272 · DOI
- 10.1109/TIM.2003.809484 · doi:10.1109/tim.2003.809484
- 10.1109/38.250916 · DOI
- 10.1109/TSMCC.2008.923862 · DOI · Paper page
- 10.1109/TCE.2010.5505962 · doi:10.1109/tce.2010.5505962
- 10.1109/ISIE.2009.5221998 · DOI
Cited by
Optoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Zhu, M., Sun, Z., Zhang, Z., Shi, Q., He, T., Liu, H., Chen, T., & Lee, C. (2020) · Science Advances · doi:10.1126/sciadv.aaz8693 · Cited by 784
“Another commercialized solution for smart gloves is to use resistive sensors (7).”
BackgroundTriboelectric nanogenerator sensors for soft robotics aiming at digital twin applications
Jin, T., Sun, Z., Li, L., Zhang, Q., Zhu, M., Zhang, Z., Yuan, G., Chen, T., Tian, Y., Hou, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19059-3 · Cited by 695
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Metadata
- Authors
- Hammond, F. L., Menguc, Y., & Wood, R. J.
- Venue
- 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems
- Publisher
- IEEE
- Published
- 2014-09
- Pages
- 4000-4007
- OpenAlex
- W2081234094
- Cited by
- 103
- References
- 0
- FWCI
- 12.21
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward a modular soft sensor-embedded glove for human hand motion and tactile pressure measurement. https://app.cochat.ai/papers/10.1109/iros.2014.6943125
- The paper
- Hammond, F. L., Menguc, Y., & Wood, R. J. (2014). Toward a modular soft sensor-embedded glove for human hand motion and tactile pressure measurement. 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems. https://doi.org/10.1109/iros.2014.6943125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.